CONTAINED IN VOL. 08.04, 2017 Specifies poly(vinyl chloride) (PVC) pipe made in standard thermoplastic pipe dimension ratios and pressure rated for water.
Committee |
F 17
|
DocumentType |
Redline
|
Pages |
9
|
PublisherName |
American Society for Testing and Materials
|
Status |
Superseded
|
SupersededBy |
1.1This specification covers poly(vinyl chloride) (PVC) pipe made in standard thermoplastic pipe dimension ratios and pressure rated for water (see appendix). Included are criteria for classifying PVC plastic pipe materials and PVC plastic pipe, a system of nomenclature for PVC plastic pipe, and requirements and test methods for materials, workmanship, dimensions, sustained pressure, burst pressure, flattening, and extrusion quality. Methods of marking are also given.
1.2The products covered by this specification are intended for use with the distribution of pressurized liquids only, which are chemically compatible with the piping materials. Due to inherent hazards associated with testing components and systems with compressed air or other compressed gases, some manufacturers do not allow pneumatic testing of their products. Consult with specific product/component manufacturers for their specific testing procedures prior to pneumatic testing.
Note 1:Pressurized (compressed) air or other compressed gases contain large amounts of stored energy which present serious safety hazards should a system fail for any reason.
Note 2:This standard specifies dimensional, performance and test requirements for plumbing and fluid handling applications, but does not address venting of combustion gases.
1.3The text of this specification references notes, footnotes, and appendixes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.
1.4The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5The following safety hazards caveat pertains only to the test methods portion, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific precautionary statement is given in Note 9.
Note 3:CPVC plastic pipe (SDR-PR), which was formerly included in this specification, is now covered by Specification F442/F442M.
Note 4:The sustained and burst pressure test requirements, and the pressure ratings in the appendix, are calculated from stress values obtained from tests made on pipe 4 in. (100 mm) and smaller. However, tests conducted on pipe as large as 24 in. (600 mm) in diameter have shown these stress values to be valid for larger diameter PVC pipe.
Note 5:PVC pipe made to this specification is often belled for use as line pipe. For details of the solvent cement bell, see Specification D2672 and for details of belled elastomeric joints, see Specifications D3139 and D3212.
ASTM F 480 : 2014 : REDLINE | Standard Specification for Thermoplastic Well Casing Pipe and Couplings Made in Standard Dimension Ratios (SDR), SCH 40 and SCH 80 |
ASTM D 2855 : 2015 : REDLINE | Standard Practice for the Two-Step (Primer and Solvent Cement) Method of Joining Poly (Vinyl Chloride) (PVC) or Chlorinated Poly (Vinyl Chloride) (CPVC) Pipe and Piping Components with Tapered Sockets |
ASCE/EWRI 12-13, 13-13, 14-13 : 2013 | STANDARD GUIDELINES FOR THE DESIGN, INSTALLATION, AND OPERATION AND MAINTENANCE OF URBAN SUBSURFACE DRAINAGE |
ICC 2009 INT. RESI.CODE & COMM.-I1 : 2009 | 2009 INTERNATIONAL RESIDENTIAL CODE & COMMENTARY - VOLUME 2: CHAPTERS 12 TO 44 |
AWWA C908 : 2001 | PVC SELF-TAPPING SADDLE TEES FOR USE ON PVC PIPE |
CSA 2.3 : 2016 | GAS-FIRED CENTRAL FURNACES |
CSA 4.9 : 2017 | GAS-FIRED LOW PRESSURE STEAM AND HOT WATER BOILERS |
CSA/ANSI Z21.13 : 2017 | GAS-FIRED LOW PRESSURE STEAM AND HOT WATER BOILERS |
ASME B31.3:2016 | PROCESS PIPING |
API 15LT : 1993 | SPECIFICATION FOR PVC LINED STEEL TUBULAR GOODS |
ASTM D 2672 : 2014 : REDLINE | Standard Specification for Joints for IPS PVC Pipe Using Solvent Cement |
AWWA C905 : 2010 | POLYVINYL CHLORIDE (PVC) PRESSURE PIPE AND FABRICATED FITTINGS, 14 IN. THROUGH 48 IN. (350 MM THROUGH 1,200 MM), FOR WATER TRANSMISSION AND DISTRIBUTION |
ICC IPC CODE & COMMENTARY : 2015 | IPC® Code and Commentary |
ICC IRC CODE AND COMMENTARY VOLUME 2 : 2015 | IRC® Code and Commentary, Volume 2 |
ICC ISPSC CODE AND COMMENTARY : 2015 | ISPSC® Code and Commentary |
ICC IMC Code and Commentary : 2015 | IMC® Code and Commentary |
ICC 2012 INTERNATIONAL RESI. CODE : 2012 | INTERNATIONAL RESIDENTIAL CODE FOR ONE- AND TWO-FAMILY DWELLINGS |
ICC 2012 INTERNATIONAL PLUMBING CODE : 2012 | INTERNATIONAL PLUMBING CODE (INCLUDES IPSDC) |
ICC ISPSC INTERNATIONAL SWIMMING POOL AND SPA CODE : 2015 | INTERNATIONAL SWIMMING POOL AND SPA CODE[TM] (ISPSC[TM]) |
ASTM F 1176 : 2001 : EDT 1 | Standard Practice for Design and Installation of Underground Thermoplastic Irrigation Systems With Maximum Working Pressure of 125 psi (Withdrawn 2010) |
FM 1612 : 2016 | POLYVINYL CHLORIDE (PVC) PIPE AND FITTING FOR UNDERGROUND FIRE PROTECTION SERVICE |
AWWA M23 : 2 | PVC PIPE - DESIGN AND INSTALLATION |
ANSI Z21.47 : 2016 | GAS-FIRED CENTRAL FURNACES |
ASAE S376.1 : 1992 | DESIGN, INSTALLATION AND PERFORMANCE OF UNDERGROUND, THERMOPLASTIC IRRIGATION PIPELINES |
NSF 14 : 2016 | PLASTICS PIPING SYSTEM COMPONENTS AND RELATED MATERIALS |
ASTM F 1176 : 2001 | Standard Practice for Design and Installation of Underground Thermoplastic Irrigation Systems With Maximum Working Pressure of 125 psi |
ICC 2012 INTERNATIONAL MECH. CODE : 2012 | INTERNATIONAL MECHANICAL CODE |
ASME RTP 1 : 2015 | REINFORCED THERMOSET PLASTIC CORROSION-RESISTANT EQUIPMENT |
ASME RTP-1 : 2017 | REINFORCED THERMOSET PLASTIC CORROSION-RESISTANT EQUIPMENT |
ASME B31.3 SPANISH : 2010 | PROCESS PIPING |
NSF 61 : 2016 | DRINKING WATER SYSTEM COMPONENTS - HEALTH EFFECTS |
ASTM D 618 : 2013 : REDLINE | Standard Practice for Conditioning Plastics for Testing |
NSF 14 : 2016 | PLASTICS PIPING SYSTEM COMPONENTS AND RELATED MATERIALS |
ASTM D 2672 : 2014 : REDLINE | Standard Specification for Joints for IPS PVC Pipe Using Solvent Cement |
ASTM D 2444 : 1999 | Standard Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (Falling Weight) |
ASTM D 2122 : 2016 : REDLINE | Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings |
ASTM D 1784 : 2011 : REDLINE | Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.