AS/NZS ISO 389.3:2019
Current
The latest, up-to-date edition.
Acoustics - Reference zero for the calibration of audiometric equipment Reference equivalent threshold vibratory force levels for pure tones and bone vibrators
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
25-02-2019
The objective of this Standard is to specify the following data applicable to the calibration of bone vibrators for pure-tone bone-conduction audiometry: (a) reference equivalent threshold vibratory force levels (RETVFL), corresponding to the threshold of hearing of young otologically normal persons by bone-conduction audiometry; (b) essential characteristics of the bone vibrator and the method of coupling to the test subject, and to the mechanical coupler; and (c) essential characteristics of the masking noise and the baseline masking noise level applied to the ear not under test.
Committee |
AV-003
|
DocumentType |
Standard
|
ISBN |
978 1 76072 374 3
|
Pages |
13
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This part of ISO 389 specifies the following data applicable to the calibration of bone vibrators for pure-tone bone-conduction audiometry:
a) reference equivalent threshold vibratory force levels (RETVFL), corresponding to the threshold of hearing of young otologically normal persons by bone-conduction audiometry;
b) essential characteristics of the bone vibrator and the method of coupling to the test subject, and to the mechanical coupler;
c) essential characteristics of the masking noise and the baseline masking noise level applied to the ear not under test.
Guidance on the practical application of this part of ISO 389 in the calibration of audiometers is given in Annex B.
RETVFL is the vibratory force level transmitted to a mechanical coupler of specified characteristics by a vibrator when applied to the mechanical coupler under stated conditions of test and when energized at the voltage level corresponding to the normal threshold of hearing for location on the mastoid prominence.
NOTE 1 Values for the differences in reference equivalent threshold vibratory force levels between location on the forehead and mastoid are included for information in Annex C.
NOTE 2 Recommended procedures for carrying out bone-conduction audiometry are specified in ISO 8253-1.
Standards | Relationship |
ISO 389-3:2016 | Identical |
Originated as AS ISO 389.3-2007 and AS/NZS 1591.1:1995.
Revised, amalgamated and redesignated as AS/NZS ISO 389.3:2019.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.