AS/NZS 4761.2:2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

21-01-2003

Superseded date

29-05-2024

Superseded by

AS/NZS 4761.2:2008

£67.62
Excluding VAT

1 - AS/NZS 4761.2:2003 COMPETENCIES FOR WORKING WITH ELECTRICAL EQUIPMENT FOR HAZARDOUS AREAS (EEHA) - GUIDE FOR TRAINING AND ASS
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
8 - SECTION 1 SCOPE AND GENERAL
8 - 1.1 SCOPE
8 - 1.2 APPLICATION
8 - 1.3 REFERENCED DOCUMENT
8 - 1.4 DEFINITIONS
9 - SECTION 2 TRAINING/LEARNING STRUCTURE
9 - 2.1 GENERAL
9 - 2.2 TRAINING/ LEARNING STRUCTURE
15 - SECTION 3 CURRICULUM
15 - 3.1 GENERAL
15 - 3.2 MODULE INFORMATION
17 - 3.3 CONTENT OF MODULES
17 - 3.3.1 NUEH 001-Explosion-protection principles
19 - 3.3.2 NUEH 002-Explosion-protected equipment
22 - 3.3.3 NUEH 003-Hazardous areas installation and maintenance
23 - 3.3.4 NUEH 004-Hazardous areas detailed inspection techniques
24 - 3.3.5 NUEH 005-Explosion-protected equipment overhaul and repair
25 - 3.3.6 NUEH 006-Explosion-protected equipment modification
26 - 3.3.7 NUEH 007-Hazardous areas installation design
27 - 3.3.8 NUEH 008-Hazardous areas classification techniques
28 - 3.3.9 NUEH 009-Hazardous areas close inspection requirements
29 - 3.3.10 NUEH 010-Hazardous areas management
29 - 3.3.11 NUEH 011-Explosion-protected electrical systems design
30 - 3.3.12 NUEH 012-Explosion-protected equipment conformity assessment
31 - 3.3.13 NUEH 013-Hazardous areas installation testing
31 - 3.3.14 NUEH 014-Explosion-protection visual checks
32 - 3.3.15 NUEH 015-Gas detection: portable devices
32 - 3.3.16 NUEH 016-Gas detection: fixed equipment
33 - 3.3.17 NUEH 017-Evaluation and selection of gas detection equipment: portable and fixed
33 - 3.4 ASSESSMENT STRATEGY
33 - 3.4.1 General
33 - 3.4.2 Assessment methods
33 - 3.4.3 Conditions of assessment
34 - 3.5 TRAINING DELIVERY
34 - 3.5.1 Delivery strategy
34 - 3.5.2 Resource requirements
34 - 3.5.3 Occupational health and safety requirements
35 - SECTION 4 WORK PERFORMANCE
35 - 4.1 GENERAL
35 - 4.2 MODULE INFORMATION
36 - 4.3 CONTENT OF MODULES
36 - 4.3.1 NHWP 001-Hazardous areas installation work performance
36 - 4.3.2 NHWP 002-Hazardous areas maintenance work performance
37 - 4.3.3 NHWP 003-Hazardous areas installation testing work performance
37 - 4.3.4 NHWP 004-Hazardous areas close inspection work performance
37 - 4.3.5 NHWP 005-Hazardous areas detailed inspection work performance
38 - 4.3.6 NHWP 006-Hazardous areas installation design work performance
38 - 4.3.7 NHWP 007-Explosion-protected equipment overhaul and repair work performance
39 - 4.3.8 NHWP 008-Explosion-protected equipment modification design work performance
39 - 4.3.9 NHWP 009-Explosion-protected equipment conformity assessment work performance
39 - 4.3.10 NHWP 010-Hazardous areas classification work performance
40 - 4.3.11 NHWP 011-Explosion-protected electrical system design work performance
40 - 4.3.12 NHWP 012-Hazardous areas maintenance management work performance
41 - 4.3.13 NHWP 013-Hazardous areas management work performance
41 - 4.3.14 NSHWP 014-Hazardous areas operations reporting work performance
41 - 4.3.15 NHWP 015-Hazardous areas attend- to- breakdown work performance
42 - 4.3.16 NHWP 016-Portable gas detection equipment work performance
42 - 4.3.17 NWHP 017-Fixed gas detection equipment work performance
42 - 4.3.18 NHWP 18-Design gas detection systems work performance
43 - 4.4 ASSESSMENT STRATEGY
43 - 4.4.1 General
43 - 4.4.2 Assessment methods
43 - 4.4.3 Conditions of assessment
43 - 4.4.4 Evidence of competency
43 - 4.4.5 Resource requirements
43 - 4.4.6 Occupational health and safety requirements
43 - 4.4.7 Endorsement
45 - AMENDMENT CONTROL SHEET

Provides guidance for the set up of training and assessment programs applicable to the units of competency described in Part 1; it is intended for use by training providers to develop programs and by learners as a guide to the extent of knowledge and skills required to be deemed competent.

Committee
P-012
DocumentType
Standard
ISBN
0 7337 4999 2
Pages
37
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Part of the Standard provides a consolidation of the knowledge and skills that define the Units of Competency(AUS)/Unit Standards(NZ) described in Part 1. The knowledge and skills which have been derived from the Units of Competency(AUS)/Unit Standards(NZ) are in learning descriptors form, to assist in the development of structured training/learning and assessment programs.

First published as part of AS/NZS 4761.1(Int):2000, AS/NZS 4761.2(Int):2000, AS/NZS 4761.3(Int):2000 and AS/NZS 4761.4(Int):2000.
AS/NZS 4761.1(Int):2000, AS/NZS 4761.2(Int):2000, AS/NZS 4761.3(Int):2000 and AS/NZS 4761.4(Int):2000 jointly revised, amalgamated and redesignated in part as AS/NZS 4761.2:2003.

AS/NZS 4761.1(INT):2000 Competencies for working with electrical equipment for hazardous areas (EEHA) Units of competency

MP 87.2:2007 Australian/New Zealand Certification Scheme for explosion-protected electrical equipment (ANZEx Scheme) Recognized Service Facilities Program - Basic rules and procedures
AS/NZS 61241.14:2005 Electrical apparatus for use in the presence of combustible dust Selection and installation (IEC 61241-14, Ed.1.0(2004) MOD)
AS/NZS 2290.1:2005 Electrical equipment for coal mines - Introduction and maintenance - For hazardous areas
AS/NZS 4114.2:2003 Spray painting booths, designated spray painting areas and paint mixing rooms - Installation and maintenance
AS/NZS 3800:2005 Electrical equipment for explosive atmospheres - Repair and overhaul
AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance General requirements
HB 13-2007 Electrical equipment for hazardous areas