AS/NZS 4029.2:2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Stationary batteries - Lead-acid Valve-regulated type (IEC 60896-2:1995, MOD)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

26-09-2023

Language(s)

English

Published date

06-07-2000

Preview
£55.90
Excluding VAT

1 - AS/NZS 4029.2:2000 STATIONARY BATTERIES-LEAD-ACID - VALVE-REGULATED TYPE (IEC 60896-2:1995, MOD)
4 - PREFACE
5 - CONTENTS
7 - Section 1: General
7 - 1.1 Scope and object
7 - 1.2 Normative references
8 - 1.3 Definitions
8 - 1.3.1 valve regulated cell:
8 - 1.3.2 thermal runaway:
8 - Section 2: General requirements
8 - 2.1 Mechanical strength
9 - 2.2 Control valves
9 - 2.3 Flammability of containers and lids/covers
9 - 2.4 Gas emission
9 - 2.5 Heat generation (thermal runaway)
9 - 2.6 Marking
9 - 2.6.1 Polarity
9 - 2.6.2 Information
10 - 2.7 Information for the package and the battery accommodation
10 - 2.7. 1 Package
10 - 2.7. 2 Battery accommodation
10 - Section 3: Functional characteristics
10 - 3.1 Capacity (for test, see clause 5.1)
11 - 3.2 Suitability for floating battery operation (for test, see clause 5.2)
11 - 3.3 Endurance in cycles (for test see clause 5.3)
11 - 3.4 Charge retention (for test, see clause 5.4)
12 - 3.5 Short-circuit current and internal resistance (for test, see clause 5.5)
12 - Section 4: General test conditions
12 - 4.1 Accuracy of measuring instruments
12 - 4.1.1 Electrical measuring instruments
12 - 4.1.2 Temperature measurement
12 - 4.1.3 Time measurement
12 - 4.1.4 Gas pressure measurement
12 - 4.1.5 Gas volume measurement
13 - 4.2 Preparation of cells and monobloc batteries for testing
13 - Section 5: Test methods
13 - 5.1 Capacity test (see clause 3.1) See table 2 for application
14 - 5.2 Test of suitability for floating battery operation (see clause 3.2) See table 2 for application
14 - 5.2.1 Test for voltage and capacity stability
14 - 5.3 Endurance in cycles (see also clause 3.3) See table 2 for application
15 - 5.4 Test for charge retention (see also clause 3.4) See table 2 for application
15 - 5.5 Test for short-circuit current and internal resistance for cells or monobloc batteries
18 - Section 6: Tests and test sequences
18 - 6.1 Test series (see also table 2)
18 - 6.1.1 Type tests shall be carried out in three series of tests as follows:
18 - 6.1.2 The test sequence shall be as shown in table 1.
21 - Annex A - High current safety tests
21 - A.1 Introduction
21 - A.2 Test methods
22 - Annex B - Thermal runaway
23 - Annex C - Test of seal integrity
23 - C.1 Introduction
23 - C.2 Selection of samples and requirements
23 - C.3 Thermal cycling test
23 - C.4 Mechanical test
23 - C.5 Reference documents
24 - Annex D - Test for gas emission
24 - D.1 Introduction
24 - D.2 Test method

Specifies safety requirements, methods of specifying performance and methods of test for valve-regulated, stationary, lead-acid batteries. It comprises IEC 60896-2 Stationary lead-acid batteries - General requirements and methods of test, Part 2: Valve-regulated types subject to variations for conditions in Australia and New Zealand.

Committee
EL-005
DevelopmentNote
Standard has been given Pending Revision status.
DocumentType
Standard
ISBN
0 7337 3384 0
Pages
20
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This part of IEC 896 applies to valve regulated stationary lead-acid cells and batteries for service in a fixed location (i.e. not habitually to be moved from place to place) and permanently connected to a load and to a d.c. power supply.NOTES1 Typical applications for stationary batteries, with recommended tests are shown in table 2.2 Different types of construction of lead-acid cell or battery may be used for stationary battery applications. Typical types and constructions are given in IEC 896-1 which specifies general requirements and test methods for vented types of stationary lead-acid cells and batteries.The object of this part of IEC 896 is to specify the main characteristics and corresponding test methods associated with all types and construction of valve regulated stationary lead-acid cells and batteries and their related applications. The tests may be used for type qualification, product acceptance, and as a functional test during service. The tests in the informative annexes A, B, C, and D, are not mature and are still under development. As a consequence the tests are not in common use, and are subject to agreement between the user and the supplier.NOTE Table 2 details the test relevant to the various stationary battery applications. Some tests are valid for certain applications only. Recommendations relating the type of cell or monobloc battery with the use of the tests are given in table 3.

First published as AS 4029.2-1992.
Jointly revised and designated as AS/NZS 4029.2:2000.

AS 1852.151-1988 International electrotechnical vocabulary - Electric and magnetic devices
AS 1104-1978 Informative symbols for use on electrical and electronic equipment
AS 4029.1-1994 Stationary batteries - Lead-acid Vented type (based on and including the full text of IEC 896-1)

AS 2941-2008 Fixed fire protection installations - Pumpset systems
AS/NZS 60079.0:2012 Explosive atmospheres Equipment - General requirements
AS 2293.1-2005 Emergency escape lighting and exit signs for buildings System design, installation and operation
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
HB 233-2008 Fire Protection Systems Testing - Water Conservation Handbook
AS/NZS 2201.1:2007 Intruder alarm systems Client’s premises - Design, installation, commissioning and maintenance
AS 1851-2005 Maintenance of Fire Protection Systems and Equipment
AS/NZS 2293.1:2018 Emergency lighting and exit signs for buildings System design, installation and operation

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.