AS/NZS 3000:2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical installations (known as the Australian/New Zealand Wiring Rules)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
04-07-2024
12-11-2007
The New Wiring Rules 2018 is here. Available in Hardcopy and PDF formats. Buy now.
The 2007 Wiring Rules is available incorporating Amendments 1 and 2 in a different way – check details.
Paperback – A5 size, incorporates Amendments 1 and 2
PDF – A4 size, incorporates Amendments 1 and 2.
To purchase an Unamended Paperback version in A5 size click here.
The presentation of this edition differs from previous editions of AS/NZS 3000 in that the Standard comprises two parts but with both parts bound as one document. Part 1 provides uniform essential elements that constitute the minimum regulatory requirements for a safe electrical installation. It also provides an alternative regulatory vehicle for Australian and New Zealand regulators seeking to move from the present prescription of AS/NZS 3000 in electrical installation safety and licensing legislation. Part 2 provides installation practices that achieve certainty of compliance with the essential safety requirements of Part 1. It is primarily a revision of the 2000 edition to provide work methods and installation practices that are ‘deemed to comply’ with the associated performance outcomes/safety conditions.
Committee |
EL-001
|
DocumentType |
Standard
|
ISBN |
0 7337 8391 0
|
Pages |
445
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard sets out requirements for the design, construction and verification of electrical installations, including the selection and installation of electrical equipment forming part of such electrical installations.These requirements are intended to protect persons, livestock, and property from electric shock, fire and physical injury hazards that may arise from an electrical installation that is used with reasonable care and with due regard to the intended purpose of the electrical installation.In addition, guidance is provided so that the electrical installation will function correctly for the purpose intended.
Originated as part of AS CC1 1931.
Previous edition AS/NZS 3000:2000.
Fifth edition 2007.
AS/NZS 61558.2.8:2001 | Safety of power transformers, power supply units and similar Particular requirements for bell and chime transformers (IEC 61558-2-8:1998, IDT) |
AS/NZS 60479.1:2002 | Effects of current on human beings and livestock General aspects |
AS/NZS 2648.1:1995 | Underground marking tape Non-detectable tape (Reconfirmed 2020) |
AS 1418.17-1996 | Cranes (including hoists and winches) Design and construction of workboxes (Reconfirmed 2016) |
AS/NZS 61241.10:2005 | Electrical apparatus for use in the presence of combustible dust Classification of areas where combustible dusts are or may be present |
AS 1359.106-1996 | Rotating electrical machines - General requirements Methods of cooling (IC Code) |
AS/NZS 61058.1:2002 | Switches for appliances General requirements (IEC 61058.1:2000 MOD) |
AS 1359.30-1997 | Rotating electrical machines - General requirements - Preferred outputs and frame sizes |
AS 62040.3-2002 | Uninterruptible power systems (UPS) Method of specifying the performance and test requirements |
AS/NZS 1026:2004 | Electric cables - Impregnated paper insulated - For working voltages up to and including 19/33 (36) kV |
AS 1418.13-1996 | Cranes (including hoists and winches) Building maintenance units |
AS 1670.4-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning Sound systems and intercom systems for emergency purposes |
AS/NZS 3190:2002 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS/NZS 61558.2.17:2001 | Safety of power transformers, power supply units and similar Particular requirements for transformers for switch mode power supplies (IEC 61558-2-17:1997, MOD) |
AS/NZS 2430.3.4:2004 | Classification of hazardous areas Examples of area classification - Flammable gases |
AS 1359.114-1997 | Rotating electrical machines - General requirements - Vibration measurements and limits |
AS/NZS 3017:2001 | Electrical installations - Testing and inspection guidelines |
AS 3600-2001 | Concrete structures |
AS/NZS 3018:2001 | Electrical installations - Domestic installations |
AS 60947.4.1-2004 | Low-voltage switchgear and controlgear Contactors and motor-starters - Electromechanical contactors and motor-starters |
AS/NZS 2430.3.9:2004 | Classification of hazardous areas Examples of area classification - Miscellaneous |
ISO 22967:2010 | Forced draught gas burners |
AS/NZS 3500.4:2003 | Plumbing and drainage Heated water services |
AS 60146.1.2-2002 | Semiconductor converters General requirements and line commutated converters - Application guide (Reconfirmed 2014) |
AS/NZS 3015:2004 | Electrical installations - Extra-low voltage d.c. power supplies and service earthing within public telecommunications networks |
AS/NZS 4296:1995 | Cable trunking systems (Reconfirmed 2016) |
AS/NZS 3500.2:2003 | Plumbing and drainage Sanitary plumbing and drainage |
AS/NZS 60598.1:2003 | Luminaires General requirements and tests (IEC 60598-1:2003, MOD) |
AS 1359.31-1997 | Rotating electrical machines - General requirements Three-phase induction motors - Operation on unbalanced voltages |
AS/NZS 1735.18:2002 | Lifts, escalators, and moving walks Passenger lifts for private residence - Automatically controlled |
AS/NZS 3133:2003 | Approval and test specification - Air break switches |
AS 1418.6-2004 | Cranes, hoists and winches Guided storing and retrieving appliances (Reconfirmed 2018) |
AS 1418.14-1996 | Cranes (including hoists and winches) Requirements for cranes subject to arduous working conditions |
AS 1418.7-1999 | Cranes (including hoists and winches) Builders hoists and associated equipment |
AS 1359.101-1997 | Rotating electrical machines - General requirements Rating and performance |
AS 62040.2-2001 | Uninterruptible power systems (UPS) - Electromagnetic compatibility (EMC) requirements |
AS 2209-1994 | Timber - Poles for overhead lines |
AS/NZS 60479.2:2002 | Effects of current on human beings and livestock Special aspects |
AS/NZS 3008.1.1:1998 | Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS 10745-1998 | Information technology - Open Systems Interconnection - Upper layers security model |
AS 2067-1984 | Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV |
AS 1418.10(INT)-2004 | Cranes, hoists and winches Elevating work platforms |
AS/NZS 61008.1:2004 | Residual current operated circuit breakers without integral overcurrent protection for household and similar uses (RCCBs) General rules (IEC 61008-1, Ed. 2.1 (2002) MOD) |
HB 301-2001 | Electrical installations - Designing to the Wiring rules |
AS/NZS 3102:2002 | Approval and test specification - Electric duct heaters (Reconfirmed 2016) |
AS/NZS 61535.1:2003 | Installation couplers General requirements |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS/NZS 3123:2005 | Approval and test specification - Plugs, socket-outlets and couplers for general industrial application (Reconfirmed 2016) |
AS/NZS 3012:2003 | Electrical installations - Construction and demolition sites |
AS/NZS 2430.3.1:2004 | Classification of hazardous areas Examples of area classification - General |
AS/NZS 5000.2:2006 | Electric cables - Polymeric insulated For working voltages up to and including 450/750 V (Reconfirmed 2017) |
AS 4509.1-1999 | Stand-alone power systems Safety requirements |
AS/NZS 2430.3.6:2004 | Classification of hazardous areas Examples of area classification - Laboratories, including fume cupboards and flammable medical agents |
AS 1074-1989 | Steel tubes and tubulars for ordinary service (Reconfirmed 2018) |
AS 2220.1-1989 | Emergency warning and intercommunication systems in buildings Equipment design and manufacture |
AS 1670.3-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning - Fire alarm monitoring |
AS/NZS 3008.1.2:1998 | Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions |
AS/NZS 4836:2001 | Safe working on low-voltage electrical installations |
AS/NZS 2381.1:2005 | Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance General requirements |
AS/NZS 3010:2005 | Electrical installations - Generating sets |
AS 1735.2-2001 | Lifts, escalators and moving walks Passenger and goods lifts - Electric |
AS/NZS 4396:1999 | Connectors - Insulation piercing - For 0.6/1 kV aerial bundled cables |
AS/NZS 2430.3.7:2004 | Classification of hazardous areas Examples of area classification - Landfill gas, sewage treatment and sewage pumping plants |
AS 4777.2-2005 | Grid connection of energy systems via inverters Inverter requirements |
AS/NZS 3019:2007 | Electrical installations - Periodic verification |
AS/NZS 3760:2003 | In-service safety inspection and testing of electrical equipment |
AS 4070-1992 | Recommended practices for protection of low-voltage electrical installations and equipment in MEN systems from transient overvoltages (Reconfirmed 2015) |
AS/NZS 3500.1:2003 | Plumbing and drainage Water services |
AS 1418.2-1997 | Cranes (including hoists and winches) Serial hoists and winches |
AS 3600 SUPP 1-1994 | Concrete structures - Commentary (Supplement to AS 3600-1994) |
AS 3011.1-1992 | Electrical installations - Secondary batteries installed in buildings - Vented cells Vented cells |
AS/NZS 3947.3:2001 | Low-voltage switchgear and controlgear Switches, disconnectors, switch-disconnectors and fuse-combination units |
AS 4388-1996 | A method of temperature-rise assessment by extrapolation for partially type-tested assemblies (PTTA) of low-voltage switchgear and controlgear |
AS/NZS 60598.2.22:2005 | Luminaires Particular requirements - Luminaires for emergency lighting (IEC 60598-2 22, Ed. 3.1(2002) MOD) |
AS 1418.18-2001 | Cranes, hoists and winches Crane runways and monorails |
AS 60269.3.1-2005 | Low-voltage fuses Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) - Sections I to IV: Examples of types of standardized fuses |
AS 1418.15-1994 | Cranes (including hoists and winches) - Concrete placing equipment |
AS/NZS 3002:2002 | Electrical installations - Shows and carnivals |
AS/NZS 60335.2.80:2004 | Household and similar electrical appliances - Safety Particular requirements for fans (IEC 60335-2-80 Ed 2.2, MOD) |
UNI EN ISO 9170-1 : 2008 | TERMINAL UNITS FOR MEDICAL GAS PIPELINE SYSTEMS - PART 1: TERMINAL UNITS FOR USE WITH COMPRESSED MEDICAL GASES AND VACUUM |
AS/NZS 2430.3.3:2004 | Classification of hazardous areas Examples of area classification - Flammable liquids |
AS/NZS 61558.2.7:2001 | Safety of power transformers, power supply units and similar Particular requirements for transformers for toys (IEC 61558-2-7:1997, MOD) |
AS/NZS 3014:2003 | Electrical installations - Electric fences |
16/30314880 DC : 0 | BS EN ISO 9170-1 - TERMINAL UNITS FOR MEDICAL GAS PIPELINE SYSTEMS - PART 1: TERMINAL UNITS FOR USE WITH COMPRESSED MEDICAL GASES AND VACUUM |
AS 1418.5-2002 | Cranes, hoists and winches Mobile cranes |
BS ISO 22968:2010 | Forced draught oil burners |
AS/NZS 60079.10:2004 | Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD) |
AS 1359.0-1998 | Rotating electrical machines - General requirements Introduction and list of Parts |
AS/NZS 60898.2:2004 | Circuit-breakers for overcurrent protection for household and similar installations Circuit-breakers for a.c. and d.c. operation (IEC 60898-2, Ed. 1.1 (2003) MOD) (Reconfirmed 2016) |
AS 3011.2-1992 | Electrical installations - Secondary batteries installed in buildings Sealed cells |
AS/NZS 60598.2.23:2002 | Luminaires Particular requirements - Extra low voltage lighting systems for filament lamps (IEC 60598.2.23:1996, MOD) (Reconfirmed 2016) |
AS 4702-2000 | Polymeric cable protection covers (Reconfirmed 2013) (Reconfirmed 2020) |
AS/NZS 3194:1993 | Approval and test specification - Electric shaver supply units |
AS/NZS 3009:1998 | Electrical installations - Emergency power supplies in hospitals |
AS/NZS 3131:2001 | Approval and test specification - Plugs and socket-outlets for stationary appliances |
AS 2941-2002 | Fixed fire protection installations - Pumpset systems |
AS/NZS 61558.2.3:2001 | Safety of power transformers, power supply units and similar devices Particular requirements for ignition transformers for gas and oil burners (IEC 61558-2-3:1999, IDT) |
AS/NZS 60598.2.2:2001 | Luminaires Particular requirements - Recessed luminaires (IEC 60598-2-2:1996, MOD) |
AS/NZS 5033:2005 | Installation of photovoltaic (PV) arrays |
AS 3439.4-1995 | Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS) |
AS/NZS 60898.1:2004 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations Circuit-breakers for a.c. operation (IEC 60898-1, Ed. 1.2 (2003) MOD) |
AS/NZS 61558.2.15:2001 | Safety of power transformers, power supply units and similar Particular requirements for isolating transformers for the supply of medical locations (IEC 61558-2-15:1999, MOD) |
AS 4777.3-2005 | Grid connection of energy systems via inverters Grid protection requirements |
AS 4777.1-2005 | Grid connection of energy systems via inverters Installation requirements |
AS 1418.12-1991 | Cranes (including hoists and winches) Crane collector systems (Reconfirmed 2016) |
AS/NZS 60479.3:2002 | Effects of current on human beings and livestock Effects of currents passing through the body of livestock (Reconfirmed 2016) |
AS/NZS 2785:2000 | Suspended ceilings - Design and installation |
AS/NZS 3439.5:2001 | Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies intended to be installed outdoors in public places - Cable distribution cabinets (CDCs) for power distribution in networks |
AS 2441-2005 | Installation of fire hose reels (Reconfirmed 2018) |
AS/NZS 3500.3:2003 | Plumbing and drainage Stormwater drainage |
AS 60269.1-2005 | Low-voltage fuses - General requirements |
UNI EN ISO 9170-2 : 2008 | TERMINAL UNITS FOR MEDICAL GAS PIPELINE SYSTEMS - PART 2: TERMINAL UNITS FOR ANAESTHETIC GAS SCAVENGING SYSTEMS |
AS 60038-2000 | Standard voltages |
AS/NZS 2053.2:2001 | Conduits and fittings for electrical installations Rigid plain conduits and fittings of insulating material (Reconfirmed 2016) |
AS/NZS 4249:1994 | Electrical safety practices - Film, video and television sites |
AS/NZS 4763(INT):2006 | Safety of Portable Inverters |
AS 1319-1994 | Safety signs for the occupational environment (Reconfirmed 2018) |
AS/NZS 60702.1:2005 | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V Cables |
AS 60146.2-2001 | Semiconductor converters Self-commutated semiconductor converters including direct d.c. converters (Reconfirmed 2014) |
AS/NZS 3003:2003 | Electrical installations - Patient treatment areas of hospitals and medical, dental practices and dialyzing locations |
BS EN ISO 9170-2:2008 | Terminal units for medical gas pipeline systems Terminal units for anaesthetic gas scavenging systems |
AS 2419.1-2005 | Fire hydrant installations System design, installation and commissioning |
AS 2293.1-2005 | Emergency escape lighting and exit signs for buildings System design, installation and operation |
AS/NZS 2430.3.2:2004 | Classification of hazardous areas - Examples of area classification - Vehicle workshops, vehicle parking, fuel dispensing stations and aircraft hangars |
AS 60146.1.3-2002 | Semiconductor converters General requirements and line commutated converters - Transformers and reactors |
AS/NZS 3439.1:2002 | Low-voltage switchgear and controlgear assemblies Type-tested and partially type tested assemblies (IEC 60439-1:1999 MOD) |
AS/NZS 3004:2002 | Electrical installations - Marinas and pleasure craft at low-voltage |
AS 1359.102.2-1997 | Rotating electrical machinery - General requirements Methods for determining losses and efficiency - Calorimetric method |
ISO 22968:2010 | Forced draught oil burners |
AS/NZS 3500.0:2003 | Plumbing and drainage Glossary of terms |
AS/NZS 3016:2002 | Electrical installations - Electric security fences |
I.S. EN ISO 9170-2:2008 | TERMINAL UNITS FOR MEDICAL GAS PIPELINE SYSTEMS - PART 2: TERMINAL UNITS FOR ANAESTHETIC GAS SCAVENGING SYSTEMS |
AS/NZS 60598.2.20:2002 | Luminaires Particular requirements - Lighting chains (IEC 60598-2-20:1996, MOD) |
AS 2118.1-2006 | Automatic fire sprinkler systems General systems |
AS/NZS 61241.14:2005 | Electrical apparatus for use in the presence of combustible dust Selection and installation (IEC 61241-14, Ed.1.0(2004) MOD) |
AS 1418.1-2002 | Cranes, hoists and winches General requirements |
EN ISO 9170-1:2008 | Terminal units for medical gas pipeline systems - Part 1: Terminal units for use with compressed medical gases and vacuum (ISO 9170-1:2008) |
AS/NZS 61558.2.4:2001 | Safety of power transformers, power supply units and similar Particular requirements for isolating transformers for general use (IEC 61558-2-4:1997, MOD) |
AS 1418.11-2004 | Cranes, hoists and winches - Vehicle-loading cranes |
AS 1883-1992 | Guide to maintenance and supervision of insulating oils in service |
AS/NZS 3820:1998 | Essential safety requirements for low voltage electrical equipment |
AS 1418.8-2002 | Cranes, hoists and winches - Special purpose appliances |
I.S. EN ISO 9170-1:2008 | TERMINAL UNITS FOR MEDICAL GAS PIPELINE SYSTEMS - PART 1: TERMINAL UNITS FOR USE WITH COMPRESSED MEDICAL GASES AND VACUUM |
AS/NZS 3832:1998 | Electrical installations - Cold-cathode illumination systems |
AS/NZS 3013:2005 | Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020) |
AS/NZS 61558.2.5:2003 | Safety of power transformers, power supply units and similar Particular requirements for shaver transformers (IEC 61558-2-5:1997, MOD) |
AS/NZS 61009.1:2004 | Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 2.1 (2003) MOD) |
AS 1359.107-1996 | Rotating electrical machines - General requirements - Classification of types of construction and mounting arrangements (IM Code) |
AS 1359.102.1-1997 | Rotating electrical machines - General requirements Methods for determining losses and efficiency - General |
AS 4154-1993 | General access floors (elevated floors) |
AS 5601-2004 | Gas installations |
AS 1418.19-2007 | Cranes, hoists and winches Telescopic handlers |
ISO 9170-1:2017 | Terminal units for medical gas pipeline systems — Part 1: Terminal units for use with compressed medical gases and vacuum |
AS 62040.1.2-2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in restricted access locations |
AS/NZS 60335.2.76:2003 | Household and similar electrical appliances - Safety Particular requirements for electric fence energizers (IEC 60335-2-76 Ed 2.2, MOD) (Reconfirmed 2016) |
BS ISO 22967:2010 | Forced draught gas burners |
AS/NZS 60598.2.25:2001 | Luminaires Particular requirements - Luminaires for use in clinical areas of hospitals and health care buildings (IEC 60598.2.25:1994, MOD) (Reconfirmed 2013) (Reconfirmed 2024) |
AS 3007.2-2004 | Electrical installations - Surface mines and associated processing plant - General protection requirements |
AS 60146.1.1-2002 | Semiconductor converters General requirements and line commutated converters - Specifications of basic requirements |
AS/NZS 3500.5:2000 | Plumbing and Drainage Domestic installations |
AS 60947.8-2005 | Low-voltage switchgear and controlgear - Control units for built-in thermal protection (PTC) for rotating electrical machines |
AS/NZS 3439.2:2002 | Low-voltage switchgear and controlgear assemblies Particular requirements for busbar trunking systems (busways) |
AS/NZS 1668.1:1998 | The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings |
AS/NZS 2430.3.5:2004 | Classification of hazardous areas Examples of area classification - Refineries and major processing plants |
AS/RISSB 7722 : 2016 | EMC Management |
AS/NZS 3191:2003 | Electric flexible cords |
AS 1670.1-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning Fire |
DIN EN ISO 9170-1:2016-09 (Draft) | TERMINAL UNITS FOR MEDICAL GAS PIPELINE SYSTEMS - PART 1: TERMINAL UNITS FOR USE WITH COMPRESSED MEDICAL GASES AND VACUUM |
IEEE 242-2001 | IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book) |
ISO 9170-2:2008 | Terminal units for medical gas pipeline systems — Part 2: Terminal units for anaesthetic gas scavenging systems |
EN ISO 9170-2:2008 | Terminal units for medical gas pipeline systems - Part 2: Terminal units for anaesthetic gas scavenging systems (ISO 9170-2:2008) |
AS 1418.3-1997 | Cranes, hoists and winches Bridge, gantry, portal (including container cranes) and jib cranes (Reconfirmed 2016) |
AS 2118.1-1999 | Automatic fire sprinkler systems General requirements |
AS/NZS 2430.3.8:2004 | Classification of hazardous areas Examples of area classification - Surface coatings and adhesives |
AS 62040.1.1-2003 | Uninterruptible power systems (UPS) General and safety requirements for UPS used in operator access areas |
AS/NZS 61558.2.23:2001 | Safety of power transformers, power supply units and similar devices Particular requirements for transformers for construction sites (IEC 61558-2-23:2000, MOD) |
AS/NZS 61558.1:2000 | |
AS 1359.109-1998 | Rotating electrical machines - General requirements - Noise limits |
AS 1418.16-1997 | Cranes (including hoists and winches) Mast climbing work platforms |
AS/NZS 3001:2001 | Electrical installations - Relocatable premises (including caravans and tents) and their site installations |
AS/NZS 2589.1:1997 | Gypsum linings in residential and light commercial construction - Application and finishing Gypsum plasterboard |
AS/NZS 61558.2.6:2001 | Safety of power transformers, power supply units and similar Particular requirements for safety isolating transformers for general use (IEC 61558-2-6:1997, MOD) |
DIN EN ISO 9170-2:2009-09 | TERMINAL UNITS FOR MEDICAL GAS PIPELINE SYSTEMS - PART 2: TERMINAL UNITS FOR ANAESTHETIC GAS SCAVENGING SYSTEMS |
BS EN ISO 9170-1:2008 | Terminal units for medical gas pipeline systems Terminal units for use with compressed medical gases and vacuum |
AS 1418.4-2004 | Cranes, hoists and winches Tower cranes |
AS 1670.6-1997 | Fire detection, warning, control and intercom systems - System design, installation and commissioning Smoke alarms |
AS/NZS 1768:2007 | Lightning protection |
AS 60947.2-2005 | Low-voltage switchgear and controlgear - Circuit-breakers |
AS/NZS 3808:2000 | Insulating and sheathing materials for electric cables (Reconfirmed 2017) |
AS/NZS 1125:2001 | Conductors in insulated electric cables and flexible cords (Reconfirmed 2017) |
AS 2118.10-1995 | Automatic fire sprinkler systems Approval documentation (Reconfirmed 2013) |
AS/NZS 3112:2004 | Approval and test specification - Plugs and socket-outlets |
AS/NZS 61558.2.9:2003 | Safety of power transformers, power supply units and similar products Particular requirements for transformers for class III handlamps for tungsten filament lamps (IEC 61558-2-9:2002, MOD) |
AS 60529-2004 | Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018) |
AS/NZS 3439.3:2002 | Low-voltage switchgear and controlgear assemblies Particular requirements for low voltage switchgear and controlgear assemblies intended to be installed in places where unskilled persons have access for their use - Distribution boards (IEC 60439-3:1990 MOD) |
AS/NZS 5000.1:2005 | Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017) |
CSA Z9170.1 : 2011 | TERMINAL UNITS FOR MEDICAL GAS PIPELINE SYSTEMS - PART 1: TERMINAL UNITS FOR USE WITH COMPRESSED MEDICAL GASES, VACUUM, AND ANAESTHETIC GAS SCAVENGING SYSTEMS |
CSA Z9170.1 : 2011 : R2015 | TERMINAL UNITS FOR MEDICAL GAS PIPELINE SYSTEMS - PART 1: TERMINAL UNITS FOR USE WITH COMPRESSED MEDICAL GASES, VACUUM, AND ANAESTHETIC GAS SCAVENGING SYSTEMS |
AS/NZS 61008.1:2011 | Residual current operated circuit breakers without integral overcurrent protection for household and similar uses (RCCBs) General rules (IEC 61008-1, Ed. 3.0 (2010) MOD) |
AS/NZS 60079.17:2009 | Explosive atmospheres Electrical installations inspection and maintenance (IEC 60079-17, Ed.4.0 (2007) MOD) |
AS/NZS 3012:2010 | Electrical installations - Construction and demolition sites |
AS 2550.1-2011 | Cranes, hoists and winches - Safe use General requirements |
AS/NZS 3800:2012 | Electrical equipment for explosive atmospheres - Repair and overhaul |
AS 1851-2012 | Routine service of fire protection systems and equipment |
AS 4553-2008 | Gas space heating appliances |
AS 5262-2011 | LP Gas mobile industrial direct fired air heaters |
AS/NZS 4755.3.5:2016 | Demand response capabilities and supporting technologies for electrical products Interaction of demand response enabling devices and electrical products - Operational instructions and connections for grid-connected electrical energy storage (EES) systems |
AS 2118.1:2017 | Automatic fire sprinkler systems General systems |
AS 1940:2017 | The storage and handling of flammable and combustible liquids |
AS/NZS 5761:2011 | In-service safety inspection and testing - Second-hand equipment prior to sale |
AS/NZS 2982:2010 | Laboratory design and construction |
AS 5062:2016 | Fire protection for mobile and transportable equipment |
AS/NZS 2243.6:2010 | Safety in laboratories Plant and equipment aspects |
AS 2476-2008 | General fumigation procedures |
AS/NZS 1546.3:2008 | On-site domestic wastewater treatment units Aerated wastewater treatment systems |
AS/NZS 4871.2:2010 | Electrical equipment for mines and quarries Distribution, control and auxiliary equipment |
AS/NZS 61058.1:2008 | Switches for appliances General requirements (IEC 61058-1, Ed. 3.1 (2000), MOD) |
AS/NZS 60335.2.79:2017 | Household and similar electrical appliances - Safety Particular requirements for high pressure cleaners and steam cleaners |
AS/NZS 3003:2018 | Electrical installations - Patient areas |
AS/NZS 3010:2017 | Electrical installations - Generating sets |
AS/NZS 61534.1:2008 | Powertrack systems General requirements (IEC 61534-1, Ed. 1 (2003) MOD) |
AS/NZS 4777.1:2016 | Grid connection of energy systems via inverters Installation requirements |
AS 2703-2008 | Vehicle loop detector sensors |
AS/NZS 3100:2017 | Approval and test specification - General requirements for electrical equipment |
AS/NZS 4836:2011 | Safe working on or near low-voltage electrical installations and equipment |
AS 1546.3:2017 | On-site domestic wastewater treatment units Secondary treatment systems |
AS/NZS 2243.8:2014 | Safety in laboratories Fume cupboards |
AS/NZS 3002:2008 | Electrical installations - Shows and carnivals |
AS/NZS 5070.1:2008 | Siting and operation of radiocommunications facilities General guidelines for fixed, mobile and broadcasting facilities including fixed location satellite earth stations independent of the operating frequency (Reconfirmed 2019) |
AS/NZS 4871.1:2010 | Electrical equipment for mines and quarries General requirements |
AS 4200.2:2017 | Pliable building membranes and underlays Installation |
AS 4722-2009 | Passenger ropeways and passenger conveyors |
AS/NZS 4871.6:2013 | Electrical equipment for mines and quarries Diesel powered machinery and ancillary equipment |
AS/NZS 60950.1:2011 | Information technology equipment - Safety General requirements (IEC 60950-1, Ed. 2.0 (2005), MOD) |
AS/NZS 3500.5:2012 | Plumbing and drainage Housing installations |
AS 2865-2009 | Confined spaces |
AS/NZS 4755.3.3:2014 | Demand response capabilities and supporting technologies for electrical products Interaction of demand response enabling devices and electrical products - Operational instructions and connections for electric storage and electric-boosted storage water heaters |
AS/NZS 4761.2:2008 | Competencies for working with electrical equipment for hazardous areas (EEHA) Guide to assessing competency |
AS 4024.3002-2009 | Safety of machinery Materials forming and shearing - Hydraulic power presses |
AS/NZS 2081:2011 | Electrical protection devices for mines and quarries (Reconfirmed 2022) |
AS 4741-2010 | Testing of connections to low voltage electricity networks (Reconfirmed 2021) |
AS 2252.6-2011 | Controlled environments Clean workstations - Design, installation and use |
AS/NZS 3004.2:2008 | Electrical installations - Marinas and recreational boats Recreational boats installations |
AS/NZS 3019:2007 | Electrical installations - Periodic verification |
AS/NZS 4853:2012 | Electrical hazards on metallic pipelines |
AS 2419.1:2017 | Fire hydrant installations System design, installation and commissioning |
AS/NZS 5762:2011 | In-service safety inspection and testing - Repaired electrical equipment |
AS/NZS 3017:2007 | Electrical installations - Verification guidelines |
AS/NZS 3008.1.1:2017 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS 2252.2-2009 | Controlled environments Biological safety cabinets Class II - Design |
AS 3533.4.2-2013 | Amusement rides and devices Specific requirements - Contained play facilities |
AS/NZS 3003:2011 | Electrical installations - Patient areas |
AS 1603.17-2011 | Automatic fire detection and alarm systems Warning equipment for people with hearing impairment |
AS 2144:2014 | Traffic signal lanterns |
AS 2941-2008 | Fixed fire protection installations - Pumpset systems |
AS 2118.4-2012 | Automatic fire sprinkler systems Sprinkler protection for accommodation buildings not exceeding four storeys in height |
AS/NZS 2290.1:2014 | Electrical equipment for coal mines - Introduction, inspection and maintenance For hazardous areas |
AS/NZS 4755.3.2:2012 | Demand response capabilities and supporting technologies for electrical products Interaction of demand response enabling devices and electrical products - Operational instructions and connections for devices controlling swimming pool pump-units |
AS 2714-2008 | The storage and handling of organic peroxides (Reconfirmed 2021) |
AS/NZS 5110:2011 | Recessed luminaire barriers (Reconfirmed 2020) |
AS/NZS 3008.1.2:2010 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions |
AS 60038-2012 | Standard voltages |
AS/NZS 4755.1:2017 | Demand response capabilities and supporting technologies for electrical products Demand Response Framework and requirements for Demand Response Enabling Devices (DREDs) |
AS 2067-2008 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 1546.4:2016 | On-site domestic wastewater treatment units Domestic greywater treatment systems |
AS/NZS 5033:2012 | Installation and safety requirements for photovoltaic (PV) arrays |
AS/NZS 4761.1:2008 | Competencies for working with electrical equipment for hazardous areas (EEHA) Competency Standards |
AS/NZS 1158.1.2:2010 | Lighting for roads and public spaces Vehicular traffic (Category V) lighting - Guide to design, installation, operation and maintenance |
AS 2941-2013 | Fixed fire protection installations - Pumpset systems |
AS/NZS 4509.1:2009 | Stand-alone power systems Safety and installation (Reconfirmed 2017) |
AS/NZS 3004.1:2008 | Electrical installations - Marinas and recreational boats Marinas |
AS 5711-2013 | Smart grid vocabulary |
AS/NZS 4703:2007 | Electrical wiring in furniture (Reconfirmed 2018) |
AS/NZS 4240.1:2009 | Remote control systems for mining equipment Design, construction, testing, installation and commissioning (Reconfirmed 2021) |
HB 242-2007 | High voltage mining equipment for use underground (Reconfirmed 2019) |
AS 3533.2-2009 | Amusement rides and devices Operation and maintenance |
AS 4852.2-2009 | Variable message signs Portable signs |
AS/NZS 3080:2013 | Information technology - Generic cabling for customer premises (ISO/IEC 11801:2011, MOD) |
AS 5092-2009 | CNG refuelling stations |
AS 4852.1-2009 | Variable message signs Fixed signs |
AS/NZS 3500.3:2018 | Plumbing and drainage Stormwater drainage |
AS/NZS 5601.1:2013 | Gas installations General installations |
AS/NZS 3084:2017 | Telecommunications installations - Telecommunications pathways and spaces for commercial buildings |
AS 3533.1-2009 | Amusement rides and devices Design and construction |
SA/SNZ HB 252:2014 | Communications cabling manual - Module 3: Residential communications cabling handbook |
AS/NZS 1546.2:2008 | On-site domestic wastewater treatment units Waterless composting toilets |
AS/NZS 5026:2012 | The storage and handling of Class 4 dangerous goods (Reconfirmed 2024) |
AS/NZS 3001:2008 | Electrical installations - Transportable structures and vehicles including their site supplies |
AS 5100.5:2017 | Bridge design Concrete |
AS 4032.4:2014 | Water supply - Valves for the control of heated water supply temperatures Thermostatically controlled taps for the control of heated water supply temperatures |
AS 2578-2009 | Traffic signal controllers |
AS 4995-2009 | Greywater treatment systems for vessels operated on inland waters |
AS/NZS 61009.1:2011 | Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 3.0 (2010) MOD) |
AS/NZS 1596:2008 | The storage and handling of LP Gas |
AS 2067:2016 | Substations and high voltage installations exceeding 1 kV a.c. |
AS/NZS 3100:2009 | |
AS 4551-2008 | Domestic gas cooking appliances |
AS/NZS 5601.2:2013 | Gas installations LP Gas installations in caravans and boats for non-propulsive purposes |
AS 2252.5:2017 | Controlled environments Cytotoxic drug safety cabinets (CDSC) - Design, construction, installation, testing and use |
AS 2896-2011 | Medical gas systems - Installation and testing of non-flammable medical gas pipeline systems |
AS 1228:2016 | Pressure equipment - Boilers |
HB 13-2007 | Electrical equipment for hazardous areas |
AS/NZS 2243.9:2009 | Safety in laboratories Recirculating fume cabinets |
AS/NZS 1367:2016 | Coaxial cable and optical fibre systems for the RF distribution of digital television, radio and in-house analog television signals in single and multiple dwelling installations |
AS/NZS 3008.1.1:2009 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS/NZS 5601.1:2010 | Gas installations General installations |
AS 4825-2011 | Tunnel fire safety |
AS 2832.5-2008 | Cathodic protection of metals Steel in concrete structures |
AS/NZS 3008.1.2:2017 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions |
AS 2339:2017 | Traffic signal posts, mast arms and attachments |
AS 2550.5:2016 | Cranes, hoists and winches - Safe use Mobile cranes |
AS/NZS 4871.1:2012 | Electrical equipment for mines and quarries General requirements |
AS/NZS 3112:2017 | Approval and test specification - Plugs and socket-outlets |
AS 1375-2013 | Industrial fuel-fired appliances |
AS/NZS 1299:2009 | Electrical equipment for mines and quarries - Explosion-protected three-phase restrained plugs and receptacles for working voltages up to and including 3.3 kV (Reconfirmed 2020) |
AS 4755.3.1-2008 | Demand response capabilities and supporting technologies for electrical products Interaction of demand response enabling devices and electrical products - Operational instructions and connections for airconditioners |
AS/NZS 60079.14:2009 | Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD) |
AS 4897-2008 | The design, installation and operation of underground petroleum storage systems |
HB 252-2007 | Communications Cabling Manual - Module 3: Residential communications cabling handbook |
AS 2885.1-2012 | Pipelines - Gas and liquid petroleum Design and construction |
AS/NZS 3500.3:2015 | Plumbing and drainage Stormwater drainage |
AS/NZS 3007:2013 | Electrical equipment in mines and quarries - Surface installations and associated processing plant |
AS/NZS 4509.2:2010 | Stand-alone power systems System design (Reconfirmed 2017) |
AS 4233.2:2013 | High pressure water jetting systems Construction and performance |
AS 2118.5-2008 | Automatic fire sprinkler systems Home fire sprinkler systems (Reconfirmed 2020) |
AS/NZS 1596:2014 | The storage and handling of LP Gas |
AS/NZS 3760:2010 | In-service safety inspection and testing of electrical equipment |
AS/NZS 4755.3.1:2012 | Demand response capabilities and supporting technologies for electrical products Interaction of demand response enabling devices and electrical products - Operational instructions and connections for air conditioners |
AS/NZS 3112:2011 | Approval and test specification - Plugs and socket-outlets |
AS 5414-2012 | Bushfire water spray systems |
AS 3814-2009 | Industrial and commercial gas-fired appliances |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.