AS/NZS 1905.1:1997
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Components for the protection of openings in fire-resistant walls Fire-resistant doorsets
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
24-06-2021
English
05-03-1997
Specifies requirements for the design, construction and installation of fire-resistant doorsets including transom panels but excluding lift-landing doors and access panels, used to protect openings in walls and partitions required to resist the passage of fire. Shows the variation between Australia and New Zealand in regard to the certification, marking and identification of doorsets as determined by the building codes and practice in both countries. A series of tests by which the physical capacity of the doorsets may be measured is also included.
Committee |
FP-019
|
DocumentType |
Standard
|
ISBN |
0 7337 0933 8
|
Pages |
44
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard specifies requirements for the construction and installation of fire-resistant doorsets used to protect openings in walls and partitions which are required to resist the passage of fire.This Standard also applies to transom panels over doors, where the panels are contained within the doorframe and form part of the doorset.This Standard does not apply to lift-landing doors.NOTES:1 Where it is intended to install the fire-resistant doorset in high traffic areas, it is recommended that it be tested in accordance with Appendix A prior to fire testing and that it complies with the requirements set out therein.2 Durability designations for locksets and methods for their cycle testing, for minimal, moderate and high frequency usage, are given in AS 4145.2.3 Manufacturers of fire-resistant doorsets are strongly encouraged to implement quality control systems in accordance with AS/NZS ISO 9002.Guidance on the introduction and maintenance of suitable quality systems is given in AS/NZS ISO 9000 and AS/NZS ISO 9004.4 Guidance on information that should be supplied with an enquiry or order is given in Appendix B.5 Requirements governing lift-landing doors are given in AS 1735.11 or NZS 4332P, as applicable.6 A panel above a doorset, which is not contained within the door frame, is considered as being part of the wall and is therefore subject to the structural adequacy, integrity and insulation requirements set out in the Building Code.7 A transom or mullion within a door frame may be permanently fixed to the side members of the frame or may be removable by means of mechanical fixing.8 A smoke control system (or other external environmental conditions) can impose forces greater than 5 N on the strike. In such circumstances a substantially greater resistance force may be required of the strike to ensure the door remains in the latched position during a fire emergency.
First published in Australia as AS CA57.1-1972.
Revised and redesignated AS 1905.1-1976.
Second edition 1982.
Third edition 1984.
Fourth edition 1990.
First published in New Zealand as part of NZS 1188:1954.
Revised and redesignated in part as NZS 4232.1:1988.
AS 1905.1-1990 and NZS 4232.1:1988, jointly revised, amalgamated and designated AS/NZS 1905.1:1997.
AS/NZS ISO 9004:2000 | Quality management systems - Guidelines for performance improvements |
AS 1530.1-1994 | Methods for fire tests on building materials, components and structures Combustibility test for materials (Reconfirmed 2016) |
AS 4085-1992 | Automatic sliding door assemblies |
AS/NZS ISO 9002:1994 | Quality systems - Model for quality assurance in production, installation and servicing |
AS 1530.3-1989 | Methods for fire tests on building materials, components and structures Simultaneous determination of ignitability, flame propagation, heat release and smoke release |
AS 1851.7-1984 | Maintenance of fire protection equipment - Fire-resistant doorsets |
AS 1603.2-1997 | Automatic fire detection and alarm systems Point type smoke detectors (Reconfirmed 2016) |
AS 1670-1986 | Automatic fire detection and alarm systems - System design, installation, and commissioning |
AS 1428.1-1993 | Design for access and mobility General requirements for access - Buildings |
AS 1735.11-1986 | SAA Lift Code Fire-rated landing doors |
AS 2271-1979 | Plywood and blockboard for exterior use |
AS/NZS ISO 9000:2000 | Quality management systems - Fundamentals and vocabulary |
AS 1890-1999 | Thermally released links (Reconfirmed 2016) |
AS B194-1970 | Tapping and metallic drive screws |
AS 3600-1994 | Concrete structures |
AS 2484.1-1990 | Fire - Glossary of terms Fire tests (Reconfirmed 2016) |
AS 1603.1-1997 | Automatic fire detection and alarm systems Heat detectors (Reconfirmed 2016) |
AS 2270-1979 | Plywood and blockboard for interior use |
AS 1530.4-1990 | Methods for fire tests on building materials, components and structures Fire-resistance tests of elements of building construction |
AS 3700-1988 | Masonry in buildings (known as the SAA Masonry Code) |
AS 4145.2-1993 | Locksets Mechanical locksets for doors in buildings |
AS 4145.1-1993 | Locksets Glossary of terms |
AS 2896-1998 | Medical gas systems - Installation and testing of non-flammable medical gas pipeline systems |
AS 1940-2004 | The storage and handling of flammable and combustible liquids |
AS/NZS 1668.1:1998 | The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings |
AS 1851-2005 | Maintenance of Fire Protection Systems and Equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.