AS/NZS 1158.6:2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Lighting for roads and public spaces Luminaires
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
08-03-2023
English
23-09-2004
Sets out requirements for the design, construction, performance and testing of luminaires intended for use in Category V and Category P lighting schemes as per AS/NZS 1158.1.1 and AS/NZS 1158.3.1 respectively.
Committee |
LG-002
|
DocumentType |
Standard
|
ISBN |
0 7337 6269 7
|
Pages |
36
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This Standard applies to all luminaires, with or without integral control gear, which are intended for use in Category V lighting schemes in accordance with AS/NZS 1158.1.1 and in Category P schemes in accordance with AS/NZS 1158.3.1.The requirements set out are, in general, based on engineering practices, construction materials and components that have, by long time experience in in-field application, been shown to realise the target service life of the luminaire. However instances can arise where departure from the aforesaid requirements may be justified, particularly in the case of those relating to materials. Where this is so it is referred to in the relevant text of the Standard, e.g. Clauses 2.4.1 and 2.5.2.1. However it must be noted that such departures can reduce the target life and this reduction can be significant. The range of lamp types and wattages utilized in the luminaires has not been specified because of the great range involved and because the lamp itself is not a determinant of the target service life of the luminaire. There is long-term experience of the reliability of many of the lamps and, importantly in the context of this Standard, of the associated control gear but limited experience in the application of some lamp/control gear combinations in Category V and P lighting schemes, e.g. fluorescent lamps and electronic ballasts. NOTE: Guidance on some alternative materials for lamps and control gear is given in Appendix A.
First published in Australia as AS 3771-1990.
Second edition 1998.
First published in New Zealand as NZS 6705.2.3:1986.
AS 3771-1998 and NZS 6705.2.3:1986 jointly revised, amalgamated and redesignated as AS/NZS 1158.6:2004.
AS 60038-2000 | Standard voltages |
AS/NZS 60923:1998 | Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements (Reconfirmed 2013) |
AS 2768-1985 | Electrical insulating materials - Evaluation and classification based on thermal endurance |
AS 1874-2000 | Aluminium and aluminium alloys - Ingots and castings (Reconfirmed 2018) |
AS/NZS 61049:2002 | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements (Reconfirmed 2016) |
AS 60068.2.6-2003 | Environmental testing Tests - Test Fc: Vibration (sinusoidal) (Reconfirmed 2018) |
AS/NZS 61347.1:2002 | Lamp controlgear General and safety requirements (IEC 61347-1:2000, MOD) |
AS/NZS 2208:1996 | Safety glazing materials in buildings |
AS/NZS 60598.1:2003 | Luminaires General requirements and tests (IEC 60598-1:2003, MOD) |
AS/NZS 61048:2002 | Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements (IEC 61048:1991, MOD) |
AS/NZS 61347.2.1:2002 | Lamp controlgear Particular requirements for starting devices (other than glow starters) |
AS/NZS CISPR 15:2002 | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (CISPR 15:2000, MOD) |
AS/NZS 61231:2001 | International lamp coding system (ILCOS) (Reconfirmed 2013) |
AS/NZS 1158.0:1997 | Road lighting Introduction |
AS 1931.1-1996 | High-voltage test techniques - General definitions and test requirements |
AS 1798-1992 | Lighting poles and bracket arms - Preferred dimensions |
AS/NZS 1158.1.1:1997 | Road Lighting Vehicular traffic (Category V) lighting - Performance and installation design requirements |
AS/NZS 61347.2.9:2004 | Lamp controlgear Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) (IEC 61347-2-9:2000 MOD) |
AS/NZS 1158.3.1:1999 | Road lighting Pedestrian area (Category P) lighting - Performance and installation design requirements |
AS/NZS 3191:2003 | Electric flexible cords |
AS 3140-1994 | Approval and test specification - Edison-type screw lampholders |
AS 3961-2005 | The storage and handling of liquefied natural gas |
AS/NZS 1158.4:2009 | Lighting for roads and public spaces Lighting of pedestrian crossings |
AS/NZS 1158.3.1:2005 | Lighting for roads and public spaces Pedestrian area (Category P) lighting - Performance and design requirements |
AS/NZS 1158.1.1:2005 | Lighting for roads and public spaces Vehicular traffic (Category V) lighting - Performance and design requirements |
AS/NZS 1158.5:2007 | Lighting for roads and public spaces Tunnels and underpasses |
AS/NZS 1158.0:2005 | Lighting for roads and public spaces Introduction |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.