AS 61330-2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
High-voltage/low-voltage prefabricated substations
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-06-2017
English
01-01-2005
1 General 1.1 Scope 1.2 Normative references 1.3 Definitions2 Service conditions 2.1 Normal service conditions 2.2 Special service conditions3 Requirements for components4 Ratings 4.1 Rated voltages 4.2 Rated insulation levels 4.3 Rated frequency and number of phases 4.4 Rated normal currents and temperature rise 4.5 Rated short-time withstand currents 4.6 Rated peak withstand currents 4.7 Rated duration of short circuit 4.8 Rated supply voltage of operating devices and auxiliary circuits 4.9 Rated supply frequency of operating devices and auxiliary circuits 4.10 Rated maximum power of the prefabricated substation 4.11 Rated class of enclosure5 Design and construction 5.1 Earthing 5.2 Auxiliary equipment 5.3 Nameplate 5.4 Degree of protection and internal fault 5.5 Enclosure 5.6 Sound emission6 Type tests 6.1 Dielectric tests 6.2 Temperature-rise tests 6.3 Short-time and peak withstand current tests on earthing circuits 6.4 Functional tests 6.5 Verification of the degree of protection 6.6 Mechanical tests7 Routine tests 7.1 Voltage withstand tests on auxiliary circuits 7.2 Functional tests 7.3 Verification of correct wiring 7.4 Tests after assembly on site8 Guide to the selection of prefabricated substations for service9 Information to be given with enquiries, tenders and orders 9.1 Information with enquiries and orders 9.2 Information with tenders10 Rules for transport, erection, operation and maintenance 10.1 Conditions during transport, storage and erection 10.2 Operation 10.3 MaintenanceAnnex A (normative) - Method for testing the prefabricated substation under conditions of arcing due to an internal faultAnnex B (normative) - Test to verify the sound level of a prefabricated substationAnnex C (normative) - Mechanical impact testAnnex D (informative) - Rating of transformers in an enclosure
Specifies service conditions, rated characteristics, general structural requirements and test methods of prefabricated substations, which are cable connected, to be operated from inside or outside for alternating current of primary rated voltages above 1 kV and up to and including 52 kV, and for a transformer of maximum power 1600 KVA, for service frequencies up to and including 60 Hz for outdoor installations in locations with public accessibility.
Committee |
EL-007
|
DocumentType |
Standard
|
ISBN |
0 7337 6744 3
|
Pages |
38
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
Standards | Relationship |
IEC 61330:1995 | Identical |
First published as AS 61330-2005.
AS 2735-1984 | Dry-type power transformers |
AS 4362.1-1996 | High-voltage test techniques for low-voltage equipment Definitions, test and procedure requirements |
AS 2374.1-1997 | Power transformers General |
AS 3953-1996 | Loading guide for dry-type power transformers |
AS 1931.1-1996 | High-voltage test techniques - General definitions and test requirements |
AS 2374.6-1994 | Power transformers Determination of transformer and reactor sound levels |
AS 1852.151-1988 | International electrotechnical vocabulary - Electric and magnetic devices |
AS 1824.2-1985 | Insulation coordination (phase-to-earth and phase-to-phase, above 1 kV) - Application guide |
AS 2374.5-1982 | Power Transformers Ability To Withstand Short-Circuit |
AS 2264-1995 | A.C. insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 38 kV |
AS 60529-2004 | Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018) |
AS 2374.7-1997 | Power transformers Loading guide for oil-immersed power transformers |
AS 2650-2005 | Common specifications for high-voltage switchgear and controlgear standards (IEC 60694 Ed.2.2(2002) MOD) |
AS/NZS 3439.1:2002 | Low-voltage switchgear and controlgear assemblies Type-tested and partially type tested assemblies (IEC 60439-1:1999 MOD) |
AS 2374.1.2-2003 | Power transformers Minimum Energy Performance Standard (MEPS) requirements for distribution transformers (Reconfirmed 2016) |
AS 60947.1-2004 | Low-voltage switchgear and controlgear General rules |
AS 1852.441-1985 | International electrotechnical vocabulary - Switchgear, controlgear and fuses |
AS 60076.11-2006 | Power transformers Dry-type transformers (Reconfirmed 2016) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.