• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 2989-1992

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical equipment for coal mines - Specific requirements for high voltage circuit-breakers and disconnectors

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

29-03-2023

Language(s)

English

Published date

01-01-1992

£28.14
Excluding VAT

1 - AS 2989-1992 ELECTRICAL EQUIPMENT FOR COAL MINES - SPECIFIC REQUIREMENTS FOR HIGH VOLTAGE CIRCUIT-BREAKERS AND DISCONNECTORS
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 REFERENCED DOCUMENTS
7 - 1.3 DEFINITIONS
7 - 1.3.1 Disconnector
8 - SECTION 2 GENERAL REQUIREMENTS FOR DESIGN AND CONSTRUCTION
8 - 2.1 GENERAL
8 - 2.2 APPROVAL
8 - 2.3 CIRCUIT-BREAKER- GENERAL
8 - 2.3.1 Rating
8 - 2.3.2 Loss of insulating medium
8 - 2.3.3 Loss of supply
8 - 2.3.4 Operating mechanism
8 - 2.3.5 Operation counters
8 - 2.4 CIRCUIT-BREAKER- FIXED
8 - 2.4.1 General
8 - 2.4.2 Operating positions
8 - 2.4.3 Interlocking
8 - 2.5 CIRCUIT-BREAKER- WITHDRAWABLE
8 - 2.5.1 General
8 - 2.5.2 Operating positions
9 - 2.5.3 Isolation
9 - 2.5.4 Interlocking
9 - 2.6 DISCONNECTOR
9 - 2.6.1 Compliance
9 - 2.6.2 Rating
9 - 2.6.3 Operating positions
9 - 2.6.4 Visibility
9 - 2.6.5 Interlocking
9 - 2.7 RATED SHORT-TIME WITHSTAND CURRENT
9 - 2.8 ENCLOSURE
9 - 2.8.1 General
9 - 2.8.2 Mounting
9 - 2.8.3 Enclosure design
9 - 2.9 INSULATION, CABLES AND TERMINATIONS
9 - 2.10 AUXILIARY POWER SUPPLY ARRANGEMENTS
9 - 2.10.1 General
10 - 2.10.2 Regulatory authority insulation tests
10 - 2.11 EARTHING
10 - 2.11.1 General
10 - 2.11.2 Terminals
10 - 2.11.3 Doors and covers
10 - 2.12 SAFETY EARTHING OF OUTGOING HIGH VOLTAGE CIRCUIT
10 - 2.13 INTERLOCKING
10 - 2.14 OVERCURRENT AND SHORT-CIRCUIT PROTECTION
10 - 2.15 EARTH-FAULT PROTECTION
10 - 2.16 CIRCUIT-BREAKER TRIPPING DEVICE
11 - 2.17 MEASURING INSTRUMENTS
11 - 2.18 INDICATING DEVICES
11 - 2.19 REMOTE CONTROL
11 - 2.20 INTERNAL SEGREGATION
11 - 2.21 CABLE COUPLING DEVICES
11 - 2.22 TESTING FACILITIES
11 - 2.23 MARKING
11 - 2.24 WARNING LABELS
12 - SECTION 3 SPECIFIC REQUIREMENTS FOR ENCLOSURES FOR USE IN HAZARDOUS AREAS
12 - 3.1 GENERAL
12 - 3.2 FASTENERS
12 - 3.3 SEALING
12 - 3.4 INSULATED STUDS
12 - 3.5 OPERATING SPINDLE BUSHES
12 - 3.6 VIEWING WINDOW
12 - 3.7 APPROVAL
12 - 3.7.1 General
12 - 3.7.2 Tests for flame resistance of cables
12 - 3.7.3 Flammability of insulating materials
12 - 3.7.4 Test of windows and lenses
12 - 3.7.5 Pressure tests
12 - 3.7.6 Tests for intrinsically-safe circuits
12 - 3.7.7 Tests to determine explosion-protection characteristics
12 - 3.8 MAINTENANCE
13 - SECTION 4 SPECIFIC REQUIREMENTS FOR ENCLOSURES FOR USE IN NON-HAZARDOUS AREAS
13 - 4.1 GENERAL
13 - 4.2 ACCESS
13 - 4.3 SERVICE CONDITIONS
13 - 4.4 PRESSURE RELIEF
13 - 4.5 VISIBILITY OF EQUIPMENT
13 - 4.6 MAINTENANCE
14 - SECTION 5 TESTS
14 - 5.1 GENERAL
14 - 5.2 INSULATION RESISTANCE TEST
14 - 5.3 HIGH VOLTAGE TEST
14 - 5.3.1 General
14 - 5.3.2 Test voltage
14 - 5.3.3 Test equipment
14 - 5.3.4 Procedure
14 - 5.3.5 Criteria of acceptance
15 - 5.4 FUNCTION TEST
15 - 5.5 RATED SHORT-TIME WITHSTAND CURRENT
16 - APPENDIX A - TYPICAL CONNECTION DIAGRAMS

Specifies the requirements for an assembly which incorporates a high voltage circuit-breaker and an isolating device. It is limited to systems below ground at voltages up to and including 12 000 V a.c. The necessary provisions for isolation, safety earthing and regulatory inspection and testing procedures are also included.

Committee
EL-023
DocumentType
Standard
ISBN
0 7262 7465 8
Pages
10
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This Standard specifies requirements for high voltage circuit-breakers and disconnectors, connected to three-phase, high voltage, power reticulation systems in underground coal mines, and controlling single outlet or multiple outlet circuits at voltages up to and including 12 200 V a.c. This Standard also includes the necessary provisions for isolation, safety earthing and, where applicable, facilities for regulatory authority inspection and testing requirements.NOTE: High voltage circuit-breakers and disconnectors are generally used on three-phase systems with nominal voltages of 6600 V and 11 000 V and may require approval by the relevant regulatory authority. Enquiries concerning approval may be made to the following: Department of Minerals and Energy, N.S.W.Department of Resource Industries, Qld Department of Mines, Tas.Department of Mines, W.A.Department of Mines and Energy, S.A.Department of Industry, Technology and Resources, Vic.

First published as AS 2989-1987.
Second edition 1992.

AS 1614-1985 The design and use of reflectorized signs for mines and tunnels
AS 1300-1989 Electrical equipment for coal mines - Bolted flame-proof cable coupling devices
AS 1025.1-1984 High-voltage a.c. switchgear and controlgear - Switches and switch-disconnectors - For rated voltages above 1 kV and less than 52 kV
AS 2595.1-1992 Electrical equipment for coal mines - Electrical requirements for underground mining machines and accessories - Equipment for use in hazardous areas
AS 2380.7-1987 Electrical equipment for explosive atmospheres - Explosion-protection techniques - Intrinsic safety i
AS 1939-1990 Degrees of protection provided by enclosures for electrical equipment (IP Code)
AS 2006-1986 High voltage a.c. switchgear and controlgear - Circuit breakers for rated voltages above 1000 V
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS 2086-1995 A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 72.5 kV
AS 3573-1988 Electrical equipment for coal mines - Glossary of terms
AS 1802-1985 Reeling and trailing electric cables for underground coal mining purposes
AS 1931.2-1996 High-voltage test techniques - Measuring systems
AS 1828-1984 Electrical equipment for explosive atmospheres - Cable glands
AS 1972-1976 Cables for use below ground in coal mines (other than trailing cables)
AS 2467-1981 Maintenance of electrical switchgear
AS 2380.2-1991 Electrical equipment for explosive atmospheres - Explosion-protection techniques Flameproof enclosure d

HB 13-2000 Electrical equipment for hazardous areas

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.