AS 2067:2016
Current
The latest, up-to-date edition.
Substations and high voltage installations exceeding 1 kV a.c.
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
14-09-2016
Provides minimum requirements for the design and erection of high voltage installations in systems with nominal voltages above 1kV a.c. and nominal frequency up to and including 60Hz.
Committee |
EL-043
|
DocumentType |
Standard
|
ISBN |
978 1 76035 559 3
|
Pages |
219
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard provides minimum requirements for the design and erection of high voltage installations in systems with nominal voltages above 1 kV a.c. and nominal frequency up to and including 60 Hz, so as to provide safety and proper functioning for the use intended.For the purposes of this Standard, a high voltage installation is considered to be:(a) An electricity network substation, under the control of an electricity network operator or entity authorized by a licence or other legal instrument to convey electricity.(b) The high voltage parts of an electrical installation of a power station including all auxiliary systems and interconnecting lines and cables between power stations if on the same site.(c) Electrical installations built at offshore platforms, e.g. offshore wind power farms.(d) The high voltage parts of an electrical installation that are not covered in (a) or (b) above. This may include but not be limited to consumer and customer electrical installations serving premises such as factories, commercial facilities, industrial plants, institutional facilities and mine sites.A high voltage installation includes, but is not limited to, the following equipment:(i) High voltage electrical installations on masts, poles and towers.(ii) Switchgear and/or transformers and/or electrical equipment located outside a closed electrical operating area.(iii) Rotating electrical machines.(iv) Switchgear, controlgear and assemblies.(v) Transformers and reactors.(vi) Converters.(vii) Cables.(viii) Lines.(ix) Wiring systems.(x) Batteries, battery chargers and associated d.c. supply systems.(xi) Capacitors.(xii) Earthing systems.(xiii) Buildings and fences that are part of a closed electrical operating area.(xiv) Associated protection, control, auxiliary and ancillary systems.(xv) Structures, foundations, earthworks and drainage.NOTE: In general, a product Standard for an item of equipment takes precedence over this Standard.
Originated as AS 2067-1977.
Previous edition 2008.
Third edition AS 2067:2016.
AS/NZS ISO 31000:2009 | Risk management - Principles and guidelines |
AS 4100-1998 | Steel structures (Reconfirmed 2016) |
AS/NZS 1170.0:2002 | Structural design actions General principles |
AS/NZS 60479.1:2002 | Effects of current on human beings and livestock General aspects |
AS 5804.3-2010 | High-voltage live working Stick work |
AS 62271.1-2012 | High-voltage switchgear and controlgear Common specifications |
HB 102-1997 (CJC 6) | Coordination of power and telecommunications - Low Frequency Induction (LFI) - Application Guide to the LFI Code |
AS 1824.1-1995 | Insulation co-ordination Definitions, principles and rules |
HB 331-2012 | Overhead line design |
AS 1940-2004 | The storage and handling of flammable and combustible liquids |
AS/NZS 60079.10.1:2009 | Explosive atmospheres Classification of areas - Explosive gas atmospheres (IEC 60079-10-1, Ed.1.0(2008) MOD) |
AS/NZS 1102.111:1997 | Graphical symbols forelectrotechnical documentation Architectural and topographical installation plans and diagrams |
AS/NZS 1768:2007 | Lightning protection |
AS 5804.4-2010 | High-voltage live working Barehand work |
HB 100-2000 (CJC 4) | COORDINATION OF POWER AND TELECOMMUNICATIONS - Manual for the establishment of safe work practices and the minimization of operational interference between power systems and paired cable telecommunications systems |
AS 1824.2-1978 | Insulation coordination Application guide |
AS/NZS 5532:2013 | Manufacturing requirements for single-point anchor device used for harness-based work at height |
AS 2865-2009 | Confined spaces |
AS 3011-1987 | Electrical installations - Secondary batteries installed in buildings |
AS 1682.1:2015 | Fire, smoke and air dampers Specification |
AS/NZS 3835.2:2006 | Earth potential rise - Protection of telecommunications network users, personnel and plant Application guide |
AS 1319-1994 | Safety signs for the occupational environment (Reconfirmed 2018) |
AS 60068.2.9-2003 | Environmental testing Tests - Guidance for solar radiation testing |
AS/NZS 60479.1:2010 | Effects of current on human beings and livestock General aspects |
AS 3700-2011 | Masonry structures |
AS/RISSB 7722 : 2016 | EMC Management |
AS 1210-2010 | Pressure vessels (Reconfirmed 2021) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 1905.1:2015 | Components for the protection of openings in fire-resistant walls Fire-resistant doorsets |
AS 1682.2:2015 | Fire, smoke and air dampers Installation |
AS/NZS 1891.4:2009 | Industrial fall-arrest systems and devices Selection, use and maintenance |
AS 1359.101-1997 | Rotating electrical machines - General requirements Rating and performance |
AS 5804.2-2010 | High-voltage live working Glove and barrier work |
AS 62271.202-2008 | High-voltage switchgear and controlgear High-voltage/low-voltage prefabricated substation |
AS/NZS 3835.1:2006 | Earth potential rise - Protection of telecommunications network users, personnel and plant Code of practice |
AS/NZS 1170.2:2011 | Structural design actions Wind actions (Reconfirmed 2016) |
HB 103-1997 (CJC 7) | Coordination of power and telecommunications - Crossings code - The arrangement of overhead power and telecommunications lines, pole stay wires, and suspension wires |
AS/NZS 2344:1997 | Limits of electromagnetic interference from overhead a.c. powerlines and high voltage equipment installations in the frequency range 0.15 to 1000 MHz |
AS/NZS 1891.1:2007 | Industrial fall-arrest systems and devices Harnesses and ancillary equipment |
AS 2676.1-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Vented cells |
AS 2676.2-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Sealed cells |
AS 1170.4-2007 | Structural design actions Earthquake actions in Australia (Reconfirmed 2018) |
HB 242-2007 | High voltage mining equipment for use underground (Reconfirmed 2019) |
AS 1824.2-1985 | Insulation coordination (phase-to-earth and phase-to-phase, above 1 kV) - Application guide |
AS 62271.201-2008 | High-voltage switchgear and controlgear AC insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
AS/NZS 1668.1:2015 | The use of ventilation and air conditioning in buildings Fire and smoke control in buildings |
AS/NZS 1891.3:1997 | Industrial fall-arrest systems and devices - Fall-arrest devices |
AS 60038-2012 | Standard voltages |
AS/NZS 3013:2005 | Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020) |
AS/NZS 60079.10.2:2016 | Explosive atmospheres Classification of areas - Explosive dust atmospheres |
AS 2676.1-1990 | Guide to the installation, maintenance, testing and replacement of secondary batteries in or on buildings - Vented cells |
AS/NZS 7000:2016 | Overhead line design |
AS/NZS 3100:2009 | |
AS 2293.3-2005 | Emergency escape lighting and exit signs for buildings Emergency escape luminaires and exit signs |
AS 2444-2001 | Portable fire extinguishers and fire blankets - Selection and location (Reconfirmed 2021) |
AS/NZS 3008.1.1:2009 | Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions |
AS 62271.203-2012 | High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
AS/NZS 1891.2:2001 | Industrial fall-arrest systems and devices Horizontal lifeline and rail systems |
AS/NZS 2802:2000 | Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020) |
AS/NZS 1170.1:2002 | Structural design actions Permanent, imposed and other actions |
AS 2791-1996 | High-voltage switchgear and controlgear - Use and handling of sulphur hexafluoride (SF6) in high-voltage switchgear and controlgear |
AS 1055.1-1997 | Acoustics - Description and measurement of environmental noise General procedures |
AS ISO 10007-2003 | Quality management systems - Guidelines for configuration management |
AS/NZS 60076.2:2013 | Power transformers Temperature rise for liquid-immersed transformers (IEC 60076-2, Ed. 3.0 (2011) MOD) |
AS 62271.200-2005 | High-voltage switchgear and controlgear A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV (IEC 62271-200, Ed. 1 (2003) MOD) |
AS/NZS 60076.10:2009 | Power transformers Determination of sound levels (IEC 60076-10, Ed.1 (2001) MOD) |
AS 1931.1-1996 | High-voltage test techniques - General definitions and test requirements |
AS 5804.1-2010 | High-voltage live working General |
HB 101-1997 (CJC 5) | Coordination of power and telecommunications - Low Frequency Induction (LFI) - Code of practice for the mitigation of hazardous voltages induced into telecommunications lines |
AS 60529-2004 | Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018) |
AS/NZS 4853:2012 | Electrical hazards on metallic pipelines |
AS 3600-2009 | Concrete structures |
AS/NZS 4645.1:2018 | Gas distribution networks Network management |
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.