High-voltage test techniques - General definitions and test requirements
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-06-2017
English
01-01-1996
Applies to tests with direct, alternating and impulse voltage and with impulse currents on equipment having its highest voltage above 1 kV. This Standard is identical with and has been reproduced from IEC 60-1:1989 and its Corrigendum:1992.
Committee |
EL-007
|
DocumentType |
Standard
|
ISBN |
0 7337 0231 7
|
Pages |
68
|
PublisherName |
Standards Australia
|
Status |
Withdrawn
|
Supersedes |
This standard is applicable to:- dielectric tests with direct voltage;- dielectric tests with alternating voltage; - dielectric tests with impulse voltage;- tests with impulse current; - tests with combinations of the above.This standard is applicable only to tests on equipment having its highest voltage for equipment Um above 1 kV.This standard is not intended to be used for electromagnetic compatibility tests on electric or electronic equipment.
Standards | Relationship |
IEC 60060-1:1989 | Identical |
IEC 60060-1:1989/COR1:1992 | Identical |
First published as AS C94-1942 (being endorsement of BS 923-1940 without Amendment).
Revised and redesignated AS C328-1960.
Second edition 1965.
Revised and redesignated AS 1931.1-1976.
Second edition 1996.
AS 2886-1986 | Voltage measurement - Sphere-gap method (one sphere earthed) |
AS 1931.2-1996 | High-voltage test techniques - Measuring systems |
AS 1018-1985 | Partial discharge measurements |
AS/NZS 3133:2003 | Approval and test specification - Air break switches |
AS 62052.11-2005 | Electricity metering equipment (AC) - General requirements, tests and test conditions Metering equipment (IEC 62052-11, Ed.1.0 (2003) MOD) |
AS/NZS 61008.1:2011 | Residual current operated circuit breakers without integral overcurrent protection for household and similar uses (RCCBs) General rules (IEC 61008-1, Ed. 3.0 (2010) MOD) |
AS/NZS 3100:1997 | Approval and test specification - General requirements for electrical equipment |
AS 62052.21-2006 | Electricity metering equipment (ac) - General requirements, tests and test conditions Tariff and load control equipment (IEC 62052-21, Ed. 1.0 (2004) MOD) |
AS 3300-1996 | Approval and test specification - General requirements for household and similar electrical appliances |
AS 1418.10-1996 | Cranes (including hoists and winches) - Elevating work platforms |
AS 1429.1-1993 | Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV |
AS 62271.100-2005 | High-voltage switchgear and controlgear High-voltage alternating current circuit-breakers (IEC 62271-100, Ed. 1.1 (2003) MOD) |
AS 1767.2.1-1999 | Insulating liquids, Part 2: Test methods Determination of the breakdown voltage at power frequency (Reconfirmed 2016) |
AS 62310.1-2005 | Static transfer systems (STS) General and safety requirements (Reconfirmed 2016) |
AS/NZS 1158.6:2010 | Lighting for roads and public spaces Luminaires |
AS 4435.4-2005 | Insulators - Composite for overhead power lines - Voltages greater than 1000 V a.c. Definitions, test methods, acceptance criteria for post insulator units (Reconfirmed 2016) |
AS/NZS 3599.2:1999 | Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened |
AS 4362.2-1996 | High-voltage test techniques for low-voltage equipment Test equipment |
AS 1284.6-1992 | Electricity metering Ripple control receivers for tariff and load control |
AS 1137.3-1981 | Insulators - Porcelain and glass indoor and outdoor station post insulators (for voltages greater than 1000 V a.c.) |
AS 60044.2-2007 | Instrument transformers Inductive voltage transformers (IEC 60044-2:Ed.1.2 (2003) MOD) |
AS 4117(INT)-1993 | Surge suppression devices for telecommunication applications |
AS 61010.031-2004 | Safety requirements for electrical equipment for measurement, control and laboratory use Safety requirements for hand held probe assemblies for electrical measurement and test (IEC 61010-031:2002 MOD) |
AS/NZS 3133:2008 | Approval and test specification - Air-break switches |
AS/NZS 61058.1:2008 | Switches for appliances General requirements (IEC 61058-1, Ed. 3.1 (2000), MOD) |
AS 2264-1995 | A.C. insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 38 kV |
AS/NZS 4117:1999 | Surge protective devices for telecommunication applications |
AS/NZS 61534.1:2008 | Powertrack systems General requirements (IEC 61534-1, Ed. 1 (2003) MOD) |
AS/NZS 1300:2009 | Electrical equipment for mines and quarries - Bolted explosion-protected three-phase cable coupling devices (Reconfirmed 2020) |
AS/NZS 1768:2007 | Lightning protection |
AS 60060.3-2008 | High-voltage test techniques Definitions and requirements for on-site testing |
AS 3134(INT)-1991 | Approval and test specification - a.c. supplied electronic ballasts for tubular fluorescent lamps |
AS 1768-1991 | Lightning protection |
AS 4202-1994 | Insulating covers for electrical purposes |
AS 1307.2-1996 | Surge arresters Metal-oxide surge arresters without gaps for a.c. systems (Reconfirmed 2015) |
AS 1265-1990 | Bushings for alternating voltages above 1000 V |
AS/NZS 60137:2008 | Insulated bushings for alternating voltages above 1000 V (IEC 60137, Ed. 5.0 (2003) MOD) |
AS/NZS 1429.1:2006 | Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV |
AS IEC 60437-2005 | Radio interference test on high-voltage insulators (Reconfirmed 2016) |
AS/NZS 1660.3:1998 | Test methods for electric cables, cords and conductors Electrical tests (Reconfirmed 2017) |
AS/NZS 60076.3:2008 | Power transformers Insulation levels, dielectric tests and external clearances in air (IEC 60076-3, Ed. 2 (2000) MOD) |
AS/NZS 3190:2002 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS/NZS 4871.1:2010 | Electrical equipment for mines and quarries General requirements |
AS 2732-1984 | Guide to the lightning impulse and switching impulse testing of power transformers and reactors |
AS 1352.1-1991 | Fixed resistors for use in electronic equipment Terms and methods of test - Generic specification (QC400000) |
AS 1824.1-1995 | Insulation co-ordination Definitions, principles and rules |
AS 62217-2007 | Polymeric insulators for indoor and outdoor use with a nominal voltage > 1000 V - General definitions, test methods and acceptance criteria |
AS/NZS 2081:2011 | Electrical protection devices for mines and quarries (Reconfirmed 2022) |
AS 62271.200-2005 | High-voltage switchgear and controlgear A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV (IEC 62271-200, Ed. 1 (2003) MOD) |
AS 1154.1-2009 | Insulator and conductor fittings for overhead power lines Performance, material, general requirements and dimensions (Reconfirmed 2019) |
AS/NZS 2802:2000 | Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020) |
AS 3134-1992 | Approval and test specification - a.c. supplied electronic ballasts for tubular fluorescent lamps |
AS/NZS 60840:2006 | Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) - Test methods and requirements |
AS/NZS 4802.3:1994 | Information processing systems - Local area networks Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications |
AS/NZS 4117:1996 | Surge suppression devices for telecommunication applications |
AS/NZS 61000.4.5:1999 | Electromagnetic compatibility (EMC) Testing and measurement techniques - Surge immunity test |
AS 1824.2-1985 | Insulation coordination (phase-to-earth and phase-to-phase, above 1 kV) - Application guide |
AS 3609-2005 | Insulators - Porcelain stay type - Voltages greater than 1000 V a.c. |
AS 1284.5-1992 | Electricity metering General purpose electronic watthour meters |
AS 60270-2001 | High-voltage test techniques - Partial discharge measurements (Reconfirmed 2015) |
AS/NZS 2978:1995 | Insulating mats for electrical purposes |
AS 2629-2008 | Separable insulated connectors for power distribution systems above 1 kV (Reconfirmed 2019) |
AS 60870.2.1-1998 | Telecontrol equipment and systems Operating conditions - Power supply and electromagnetic compatibility |
AS 1418.10(INT)-2004 | Cranes, hoists and winches Elevating work platforms |
AS 4428.0-1997 | Fire detection, warning, control and intercom systems - Control and indicating equipment General requirements and test methods (Reconfirmed 2016) |
AS/NZS 2373.2:1995 | Electric cables for control and protection circuits - Twisted pair control cables |
AS 2067-1984 | Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV |
AS 60044.1-2007 | Instrument transformers Current transformers (IEC 60044-1 Ed.1.2 (2003) MOD) (Reconfirmed 2016) |
AS/NZS 61058.1:2002 | Switches for appliances General requirements (IEC 61058.1:2000 MOD) |
AS/NZS 1802:2003 | Electric cables - Reeling and trailing - For underground coal mining purposes |
AS 2263-1995 | Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above |
AS/NZS 3190:2009 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS 62271.100-2008 | High-voltage switchgear and controlgear High-voltage alternating-current circuit-breakers (IEC 62271-100, Ed. 1.2 (2006) MOD) |
AS/NZS 1418.10:2011 | Cranes, hoists and winches Mobile elevating work platforms |
AS 62103-2006 | Electronic equipment for use in power installations |
AS 1418.12-1991 | Cranes (including hoists and winches) Crane collector systems (Reconfirmed 2016) |
AS 1802-1992 | Electric cables - Reeling and trailing - For underground coal mining purposes |
AS 2326.1-1991 | On-load tap-changers - Requirements |
AS 62271.201-2008 | High-voltage switchgear and controlgear AC insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
AS 3439.1-1993 | Low-voltage switchgear and controlgear assemblies Type-tested and partially type-tested assemblies |
AS/NZS 2947.1:1999 | Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. Test methods - Insulator units |
AS/NZS 2650:2000 | Common specifications for high-voltage switchgear and controlgear standards |
AS 2067-2008 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 1284.1-1991 | Electricity metering General purpose induction watthour meters |
AS 62231-2007 | Composite station post insulators for substations with a.c. voltages greater than 1000 V up to 245 kV - Definitions, test methods and acceptance criteria |
AS 1026-1992 | Electric cables - Impregnated paper insulated - Working voltages up to and including 33 kV |
AS 1033.2-1988 | High voltage fuses (For rated voltages exceeding 1000 V) Current-limiting (Powder-filled) type (Reconfirmed 2018) |
AS 1018-1985 | Partial discharge measurements |
AS 2989-1992 | Electrical equipment for coal mines - Specific requirements for high voltage circuit-breakers and disconnectors |
AS/NZS 60898.1:2004 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations Circuit-breakers for a.c. operation (IEC 60898-1, Ed. 1.2 (2003) MOD) |
AS 3168-1991 | Approval and test specifications - Fluorescent lamp ballasts |
AS 60076.4-2006 | Power transformers Guide to the lightning impulse and switching impulse testing - Power transformers and reactors (Reconfirmed 2016) (Reconfirmed 2024) |
AS/NZS 1802:2018 | Electric cables - Reeling and trailing - For underground coal mining |
AS/NZS 3350.2.76:1998 | Safety of household and similar electrical appliances Particular requirements - Electric fence energizers |
AS 4435.1-1996 | Insulators - Composite for overhead lines - Voltages greater than 1000 V a.c. Definitions, test methods and acceptance criteria for string insulator units |
AS/NZS 1026:2004 | Electric cables - Impregnated paper insulated - For working voltages up to and including 19/33 (36) kV |
AS 2374.3.1-1992 | Power transformers Insulation levels and dielectric test - External clearances in air |
AS 1243-1982 | Voltage transformers for measurement and protection |
AS/NZS 3947.1:1998 | Low-voltage switchgear and controlgear General rules |
AS 1284.1-2004 | Electricity metering General purpose induction watthour meters (Reconfirmed 2019) |
AS 1033.1-1990 | High voltage fuses (for rated voltages exceeding 1000 V) Expulsion type (Reconfirmed 2018) |
AS 1154.1-2004 | Insulator and conductor fittings for overhead power lines - Performance, material, general requirements and dimensions |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS/NZS 2947.4:1999 | Insulators - Porcelain and glass for overhead power lines - Voltages greater than 1000 V a.c. Test methods - Insulator strings and insulator sets |
AS/NZS 61009.1:2011 | Residual current operated circuit breakers with integral overcurrent protection for household and similar uses (RCBOs) General rules (IEC 61009-1, Ed. 3.0 (2010) MOD) |
AS 3100-1994 | Approval and test specification - General requirements for electrical equipment |
AS 60052-2005 | Voltage measurement by means of standard air gaps (Reconfirmed 2016) |
AS 2374.3.0-1982 | Power transformers Insulation levels and dielectric tests - General requirements |
AS/NZS 3190:2016 | Approval and test specification - Residual current devices (current operated earth-leakage devices) |
AS 2067:2016 | Substations and high voltage installations exceeding 1 kV a.c. |
AS/NZS 3100:2009 | |
AS 2629-1983 | Separable insulated connectors for power distribution systems above 1 kV |
AS 1801-1981 | Industrial safety helmets |
AS 3190-1994 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS 61330-2005 | High-voltage/low-voltage prefabricated substations |
AS 3947.1-1993 | Low-voltage switchgear and controlgear General rules |
AS/NZS 3133:2013 | Approval and test specification - Air-break switches |
AS 4398.2-1996 | Insulators - Ceramic or glass - Station post for indoor and outdoor use - Voltages greater than 1000 V a.c. Tests |
AS 1931.2-1996 | High-voltage test techniques - Measuring systems |
AS 1029.2-1982 | Low voltage contactors - Semiconductor (solid state) (up to and including 1000 V a.c. and 1500 V d.c.) |
AS 2220.1-1989 | Emergency warning and intercommunication systems in buildings Equipment design and manufacture |
AS 4398.2-2005 | Insulators - Ceramic or glass - Station post for indoor or outdoor use - Voltages greater than 1000 V a.c. Tests (IEC 60168, Ed. 4.2 (2001) MOD) |
AS/NZS 1158.6:2004 | Lighting for roads and public spaces Luminaires |
AS 3771-1998 | Road lighting luminaires with integral control gear |
AS 1284.9-1993 | Electricity metering - Electronic watthour meters (Classes 0.2 S and 0.5 S) |
AS 2897-1986 | Power capacitors - Shunt - Rated voltages above 660 v a.c. |
AS 2802-1992 | Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) |
AS/NZS 3439.1:2002 | Low-voltage switchgear and controlgear assemblies Type-tested and partially type tested assemblies (IEC 60439-1:1999 MOD) |
AS 4168.2-1994 | Programmable controllers - Equipment requirements and tests |
AS 60034.1-2009 | Rotating electrical machines Rating and performance |
AS 2650-2005 | Common specifications for high-voltage switchgear and controlgear standards (IEC 60694 Ed.2.2(2002) MOD) |
AS 2362.8-1990 | Automatic fire detection and alarm systems - Methods of test for actuating devices - Impulse voltage withstand test |
AS/NZS 4871.1:2012 | Electrical equipment for mines and quarries General requirements |
AS 4435.4-1997 | Insulators - Composite for overhead power lines - Voltages greater than 1000 V a.c. Definitions, test methods and acceptance criteria for post insulator units |
AS/NZS 1429.1:2000 | Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV |
AS/NZS 60079.14:2009 | Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD) |
AS/NZS 1768(INT):2003 | Lightning protection |
AS 1028-1992 | Power reactors and earthing transformers |
AS/NZS 3947.1:2001 | Low-voltage switchgear and controlgear General rules |
AS/NZS 3190:2011 | Approval and test specification - Residual current devices (current-operated earth-leakage devices) |
AS 60269.2.1-2005 | Low-voltage fuses Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Sections I to VI: Examples of types of standardized fuses |
AS/NZS 1429.2:1998 | Electric cables - Polymeric insulated - For working voltages above 19/33 (36) kV up to and including 76/132 (145) kV |
AS 60947.1-2004 | Low-voltage switchgear and controlgear General rules |
AS/NZS 3129.1:1993 | Approval and test specification - Electric fence energizers Safety requirements for mains-operated electric fence energizers |
AS/NZS 4871.1:2002 | Electrical equipment for coal mines, for use underground General requirements |
AS 1660.3-1993 | |
AS/NZS 3835.1:2006 | Earth potential rise - Protection of telecommunications network users, personnel and plant Code of practice |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.