Precast reinforced concrete box culverts Small culverts (not exceeding 1200 mm span and 1200 mm height)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
18-08-2010
Provides designers, manufacturers, installers and specifiers of culverts with minimum requirements for the design, testing, manufacture and installation of precast reinforced concrete rectangular box culverts not exceeding 1200mm span and 1200mm height.
Committee |
CE-026
|
DocumentType |
Standard
|
ISBN |
978 0 7337 9659 3
|
Pages |
44
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This Standard sets out minimum requirements for the design, testing, manufacture and installation of precast reinforced concrete box culverts for conveying water not under pressure, and for carrying roadway and railway loadings permitted by AS 5100.2.Culvert units, lids, link and base slabs manufactured in accordance with this Standard can be expected to achieve a design life in excess of 100 years.Design requirements are focused on proving load and ultimate strength load testing. Alternatively, design by calculation in accordance with AS 1597.2 is acceptable.
Originated as AS A136-1963.
AS A136-1963 revised and designated, in part, as AS1597.1-1974.
Second edition 2010.
Reissued incorporating Amendment No. 1 (August 2018)
AS 3582.1-1998 | Supplementary cementitious materials for use with portland and blended cement Fly ash |
AS 3972-1997 | Portland and blended cements |
AS 1597.2-1996 | Precast reinforced concrete box culverts Large culverts (from 1500 mm span and up to and including 4200 mm span and 4200 mm height) |
AS/NZS 3582.3:2002 | Supplementary cementitious materials for use with portland and blended cement Amorphous silica |
AS 5100.2-2004 | Bridge design Design loads |
AS 1012.9-1999 | Methods of testing concrete Determination of the compressive strength of concrete specimens |
AS/NZS 1554.3:2008 | Structural steel welding Welding of reinforcing steel |
AS 3600 SUPP 1-1994 | Concrete structures - Commentary (Supplement to AS 3600-1994) |
AS 1289.5.6.1-1998 | Methods of testing soils for engineering purposes Soil compaction and density tests - Compaction control test - Density index method for a cohesionless material (Reconfirmed 2016) |
AS 3600-2009 | Concrete structures |
AS 1289.5.3.2-2004 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the field density of a soil - Sand replacement method using a sand pouring can, with or without a volume displacer (Reconfirmed 2016) |
AS 2758.1-1998 | Aggregates and rock for engineering purposes - Concrete aggregates |
AS 1289.3.6.1-2009 | Methods of testing soils for engineering purposes Soil classification tests - Determination of the particle size distribution of a soil - Standard method of analysis by sieving (Reconfirmed 2022) |
AS 1379-2007 | Specification and supply of concrete (Reconfirmed 2017) |
AS 1289.5.1.1-2003 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the dry density/moisture content relation of a soil using standard compactive effort |
AS 1012.8.1-2000 | Methods of testing concrete Method for making and curing concrete - Compression and indirect tensile test specimens |
AS 1478.1-2000 | Chemical admixtures for concrete, mortar and grout Admixtures for concrete (Reconfirmed 2018) |
AS 1289.5.5.1-1998 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the minimum and maximum dry density of a cohesionless material - Standard method (Reconfirmed 2016) |
AS 5100.5-2004 | Bridge design Concrete |
AS 3582.2-2001 | Supplementary cementitious materials for use with portland and blended cement Slag - Ground granulated iron blast-furnace |
AS 1726-1993 | Geotechnical site investigations |
AS 5100.2 SUPP 1-2007 | Bridge design Design loads - Commentary (Supplement to AS 5100.2 - 2004) |
AS 1012.1-1993 | Methods of testing concrete Sampling of fresh concrete |
AS 1012.8.2-2000 | Methods of testing concrete Method for making and curing concrete - Flexure test specimens |
AS 5100.5 SUPP 1-2008 | Bridge design Concrete - Commentary (Supplement to AS 5100.5 - 2004) |
AS/NZS 4671:2001 | Steel reinforcing materials |
AS 1289.5.3.5-1997 | Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the field dry density of a soil - Water replacement method (Reconfirmed 2013) |
AS 2304:2019 | Water storage tanks for fire protection systems |
AS 1597.2-2013 | Precast reinforced concrete box culverts Large culverts (exceeding 1200 mm span or 1200 mm height and up to and including 4200 mm span and 4200 mm height) |