• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 1028-1992

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Power reactors and earthing transformers

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Superseded by

AS/NZS 60076.6:2013

Language(s)

English

Published date

01-01-1992

Preview
£79.35
Excluding VAT

1 - AS 1028-1992 POWER REACTORS AND EARTHING TRANSFORMERS
4 - PREFACE
5 - CONTENTS
7 - SECTION 1 - GENERAL
7 - 1. Scope
7 - 2. Definitions
9 - SECTION TWO - SHUNT REACTORS
9 - 3. General
10 - 4. Definitions
11 - 5. Rating
11 - 6. Insulation level
11 - 7. Rating plates
12 - 8. Tests
16 - 9. Tolerances
16 - SECTION THREE - CURRENT-LIMITING REACTORS AND NEUTRAL-EARTHING REACTORS
16 - 10. General
17 - 11. Definitions
18 - 12. Rating
18 - 13. Insulation level
19 - 14. Ability to withstand short-time current
19 - 15. Temperature rise
19 - 16. Rating plates
20 - 17. Tests
23 - 18. Tolerances
24 - SECTION FOUR - DAMPING REACTORS
24 - 19. General
24 - 20. Definitions
24 - 21. Rating
25 - 22. Insulation level
25 - 23. Temperature rise
25 - 24. Rating plates
25 - 25. Tests
26 - 26. Tolerances
26 - SECTION FIVE - TUNING (FILTER) REACTORS
26 - 27. General
27 - 28. Definitions
28 - 29. Rating
28 - 30. Rating plates
29 - 31. Tests
30 - 32. Tolerances
30 - SECTION SIX - EARTHING TRANSFORMERS (NEUTRAL COUPLERS)
30 - 33. Introduction
30 - 34. General
31 - 35. Definitions
31 - 36. Rating
32 - 37. Ability to withstand the rated neutral current
32 - 38. Temperature rise
32 - 39. Insulation level
33 - 40. Rating plates
33 - 41. Tests
34 - 42. Tolerances
35 - SECTION SEVEN - ARC-SUPPRESSION REACTORS
35 - 43. General
35 - 44. Definitions
35 - 45. Rating
36 - 46. Adjustment range
36 - 47. Winding temperature rise
36 - 48. Insulation level
36 - 49. Rating plates
37 - 50. Tests
38 - 51. Tolerances
39 - SECTION EIGHT - SMOOTHING REACTORS
39 - 52. General
39 - 53. Definitions
40 - 54. Rating
40 - 55. Insulation level
40 - 56. Temperature rise
40 - 57. Rating plates
41 - 58. Tests
44 - 59. Tolerances
48 - AUSTRALIAN APPENDIX A - VARIATIONS FROM IEC 289 REQUIRED FOR AUSTRALIAN CONDITIONS
48 - A1 SCOPE
48 - A2 LIST
49 - AUSTRALIAN APPENDIX B - PARTICULAR REQUIREMENTS FOR EARTH CURRENT-LIMITING NEUTRAL DISPLACEMENT (ZERO-SEQUENCE) REACTORS
49 - B1 GENERAL
49 - B2 DEFINITIONS
49 - B3 ABILITY TO WITHSTAND SHORT CIRCUIT
49 - B4 INSULATION LEVELS
49 - B5 RATING PLATE
50 - B6 TESTS
51 - B7 TOLERANCES

Specifies requirements for the following type of reactors: shunt, current limiting, damping, tuning (filter), arc-suppression, smoothing reactors and earthing transformers, with the exception of small reactors with rating less than 2 kvar single-phase and 10 kvar three-phase. This Standard is technically identical with and has been reproduced from IEC 289:1988, with the addition of particular requirements for earth current-limiting neutral displacement reactors.

Committee
EL-008
DocumentType
Standard
ISBN
0 7262 7172 1
Pages
45
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This standard applies to the following types of reactors:- shunt reactors,- current-limiting reactors including neutral-earthing reactors,- damping reactors,- tuning (filter) reactors,- earthing transformers (neutral couplers), - arc-suppression reactors, - smoothing reactors, with the exception of the following reactors:- small reactors with a rating generally less than 2 kvar single-phase and 10 kvar three-phase,- reactors for special purposes such as high-frequency line traps or reactors mounted on rolling stock.Where IEC standards do not exist for such small or special reactors, this standard may be applicable in whole or in part.Where reference is made to specific clauses and sub-clauses of the various parts of IEC Publication 76: Power transformers, it is to be understood that the editions are as follows:76-1(1976) Part 1: General.76-2 (1976) Part 2: Temperature rise.76-3 (1980) Part 3: Insulation levels and dielectric tests. Amendment No.1 (1981).76-4 (1976) Part 4: Tappings and connections.76-5* (1976) Part 5: Ability to withstand short-circuit.

Standards Relationship
IEC 60289:1988 Identical

First published as AS 1028-1970.
Second edition 1992.

AS 1955.2-1978 Semiconductor convertors Semiconductor self-commutated convertors
AS 1955.3-1983 Semiconductor Convertors Semiconductor Direct D.C. Convertors (D.C. Chopper Convertors)
AS 2374.2-1997 Power transformers Temperature rise
AS 2374.6-1994 Power transformers Determination of transformer and reactor sound levels
AS 2374.5-1982 Power Transformers Ability To Withstand Short-Circuit
AS 1013-1971 Shunt capacitors for connection to power frequency systems
AS 2374.3.1-1992 Power transformers Insulation levels and dielectric test - External clearances in air
AS 2732-1984 Guide to the lightning impulse and switching impulse testing of power transformers and reactors
AS 2752-2003 Preferred numbers and their use
AS 2752-1985 Preferred numbers and their use
AS 2735-1984 Dry-type power transformers
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS 2374.1-1997 Power transformers General
AS 2374.3.0-1982 Power transformers Insulation levels and dielectric tests - General requirements
AS 1955.1-1977 Semiconductor Convertors General

AS/NZS 2081.5:2002 Electrical equipment for coal and shale mines - Electrical protection devices - Earth-fault current limiters
AS 2732-1984 Guide to the lightning impulse and switching impulse testing of power transformers and reactors
AS 2374.6-1994 Power transformers Determination of transformer and reactor sound levels
AS/NZS 2081:2011 Electrical protection devices for mines and quarries (Reconfirmed 2022)
AS 2374.8-2000 Power transformers Application guide (Reconfirmed 2016) (Reconfirmed 2024)
AS 60076.4-2006 Power transformers Guide to the lightning impulse and switching impulse testing - Power transformers and reactors (Reconfirmed 2016) (Reconfirmed 2024)
AS/NZS 60076.10:2009 Power transformers Determination of sound levels (IEC 60076-10, Ed.1 (2001) MOD)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.