High-voltage a.c. switchgear and controlgear - Switches and switch-disconnectors - For rated voltages of 52 kV and above
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
30-06-2017
English
01-01-1989
Technically equivalent to and reproduced from IEC 265-2 with changes to suit Australian requirements. Specifies requirements for a.c. switches and switch-disconnectors having, making and breaking current ratings at rated voltages of 52 kV and above, for indoor and outdoor installations. It is intended to be read in conjunction with AS 2650.
Committee |
EL-007
|
DocumentType |
Standard
|
ISBN |
0 7262 5431 2
|
Pages |
45
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This standard is applicable to three-phase alternating-current switches, having making and breaking current ratings, for indoor and outdoor installations, for rated voltages 52 kV and above; and for rated frequencies up to and including 60 Hz.This standard is also applicable to the operating devices of these switches and to their auxiliary equipment.Notes 1. - Switches for gas insulated switchgear are covered by this standard. 2. - Switches having a disconnecting function and called switch-disconnectors are also covered by IEC Publication 129. 3. - Earthing switches are not covered by this standard. Earthing switches forming an integral part of a switch are covered by IEC Publication 129.
Standards | Relationship |
IEC 60265-2:1988 | Identical |
AS 2650-1986 | High voltage a.c. switchgear and controlgear - Common requirements |
AS 1852.00-1980 | International electrotechnical vocabulary - General index |
AS 2006-1986 | High voltage a.c. switchgear and controlgear - Circuit breakers for rated voltages above 1000 V |
AS 1824.1-1995 | Insulation co-ordination Definitions, principles and rules |
AS 1306-1985 | High voltage a.c. switchgear and controlgear - Disconnectors (isolators) and earthing switches |
AS 1018-1985 | Partial discharge measurements |
AS 1265-1990 | Bushings for alternating voltages above 1000 V |
AS 2067-1984 | Switchgear assemblies and ancillary equipment for alternating voltages above 1 kV |