1 GENERAL
1.1 Scope
1.2 A systematic approach to controlling fires in large
aboveground storage tanks
1.3 How to use this publication
2 REFERENCES
2.1 Tank design, construction, safe work and operating practices
3 FIRE PREVENTION AND DESIGN
3.1 General
3.2 large aboveground tanks
3.3 Spill containment and control
3.4 Precautions against boilover
4 FIRE DETECTION AND FIRE SUPPRESSION
4.1 Detection
4.2 Fire suppression
4.3 Manual firefighting using portable and mobile equipment
4.4 Fixed water spray systems and exposure protection systems
4.5 Fire suppression considerations
APPENDIX A INCIDENT SUBMITTAL FORM
APPENDIX B ANALYSIS OF PAST FIRES
APPENDIX C SUMMARY OF CASE HISTORIES
APPENDIX D CRUDE OIL TANK BOILOVER, SLOPOVER, AND FROTHOVER
APPENDIX E FOAM FRICTION LOSS DATA
APPENDIX F PREVENTIVE DESIGN AND OPERATING PRACTICE
Figures
1 Cone-roof tank
2 Open-top floating-roof tank
B-1 Extent of single-tank fires (numbers of fires)
E-1 Static head conversion
E-2 Foam friction losses (2 1/2, 3-, 4-, 6-, 8-, and 10-inch pipe)
E-3 Foam friction losses (12-, 14-, 16-, 18-, 20- and 24-inch pipe)
E-4 Foam velocity versus foam rate: schedule 40
(2 1/2, 3-, 4-, 6-, 8-, 10-, 12- and 14-inch pipe)
E-5 Foam velocity versus expanded foam rate: schedule
40 (14-, 16- and 18-inch pipe)
E-6 Foam velocity versus expanded foam rate: schedule
40 (20- and 24-inch pipe)
Tables
1 Typical water supply requirements for foam application
(250-foot-diameter tank)
B-1 Type of tank design in case histories
B-2 Causes of large aboveground tank fires
B-3 Extent of tank fire by tank design
B-4 Extinguishment of external floating-roof tanks
B-5 Extinguishment of internal floating-roof tanks
E-1 Application method for fixed chambers of monitors
E-2 Minimum application time and minimum number of hose
streams required for a given tank size
Gives an understanding of the fire prevention and suppression issues relating to the storage of flammable and combustible liquids in large aboveground atmospheric storage tanks.
DocumentType |
Standard
|
Pages |
49
|
ProductNote |
This product is unavailable in Cuba, Iran, North Korea, Syria
|
PublisherName |
American Petroleum Institute
|
Status |
Withdrawn
|
API RP 2023 : 2001( R2006) | GUIDE FOR SAFE STORAGE AND HANDLING OF HEATED PETROLEUM-DERIVED ASPHALT PRODUCTS AND CRUDE-OIL RESIDUA |
API 2021 : 2001 : R2006 | MANAGEMENT OF ATMOSPHERIC STORAGE TANK FIRES |
API 2610:2005 | DESIGN, CONSTRUCTION, OPERATION, MAINTENANCE, AND INSPECTION OF TERMINAL AND TANK FACILITIES |
API 2023:2001 | GUIDE FOR SAFE STORAGE AND HANDLING OF HEATED PETROLEUM-DERIVED ASPHALT PRODUCTS AND CRUDE-OIL RESIDUA |
API RP 2021 : 2001 | MANAGEMENT OF ATMOSPHERIC STORAGE TANK FIRES |
API 2021 : 2001 : R2015 | MANAGEMENT OF ATMOSPHERIC STORAGE TANK FIRES |
API 2610 : 2005 : R2010 | DESIGN, CONSTRUCTION, OPERATION, MAINTENANCE, AND INSPECTION OF TERMINAL AND TANK FACILITIES |
API 500 : 2012 | RECOMMENDED PRACTICE FOR CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS AT PETROLEUM FACILITIES CLASSIFIED AS CLASS 1, DIVISION 1 AND DIVISION 2 |
NFPA 25 : 2017 | INSPECTION, TESTING, AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS |
NFPA 780 : 2017 | INSTALLATION OF LIGHTNING PROTECTION SYSTEMS |
API 653 : 2014 | TANK INSPECTION, REPAIR, ALTERATION, AND RECONSTRUCTION |
API 620 : 2013 | DESIGN AND CONSTRUCTION OF LARGE, WELDED, LOW-PRESSURE STORAGE TANKS |
API 2003 : 2015 | PROTECTION AGAINST IGNITIONS ARISING OUT OF STATIC, LIGHTNING, AND STRAY CURRENTS |
API 651 : 2014 | CATHODIC PROTECTION OF ABOVEGROUND PETROLEUM STORAGE TANKS |
API 2350 : 2012 | OVERFILL PROTECTION FOR STORAGE TANKS IN PETROLEUM FACILITIES |
NFPA 11 : 2016 | LOW-, MEDIUM-, AND HIGH-EXPANSION FOAM |
API RP 2026 : 2017 | SAFE ACCESS/EGRESS INVOLVING FLOATING ROOFS OF STORAGE TANKS IN PETROLEUM SERVICE |
API 2015 : 2014 | REQUIREMENTS FOR SAFE ENTRY AND CLEANING OF PETROLEUM STORAGE TANKS |
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
NFPA 77 : 2014 | STATIC ELECTRICITY |
API RP 2207 : 2017 | PREPARING TANK BOTTOMS FOR HOT WORK |
API 650 : 2013 | WELDED TANKS FOR OIL STORAGE |
API 652 : 2014 | LININGS OF ABOVEGROUND PETROLEUM STORAGE TANK BOTTOMS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.