Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Measurement of dose
5 Establishing the maximum acceptable dose
6 Establishing the sterilization dose
7 Installation qualification
8 Operational qualification
9 Performance qualification
10 Routine monitoring and control
Annex A (informative) - Mathematical modelling
Annex B (informative) - Tables of references for
dosimetry-related testing during IQ/OQ/PQ
Annex C (informative) - Tolerances associated
with doses used in sterilization dose
setting/substantiation in ISO 11137-2
Annex D (informative) - Application of dose
measurement uncertainty in setting process
target doses
Bibliography
Provides guidance on meeting the requirements in ISO 11137-1 and ISO 11137-2 and in ISO/TS 13004 relating to dosimetry and its use in development, validation and routine control of a radiation sterilization process.
DevelopmentNote |
Supersedes AAMI ISO 11137 and AAMI TIR27 (03/2006)
|
DocumentType |
Standard
|
ISBN |
978-1-57020-690-0
|
Pages |
49
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ISO 11137-3:2017 | Identical |
ISO/TS 13004:2013 | Sterilization of health care products — Radiation — Substantiation of selected sterilization dose: Method VDmaxSD |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO/ASTM 51401:2013 | Practice for use of a dichromate dosimetry system |
ISO/ASTM 51650:2013 | Practice for use of a cellulose triacetate dosimetry system |
ISO 11462-2:2010 | Guidelines for implementation of statistical process control (SPC) — Part 2: Catalogue of tools and techniques |
ISO/ASTM 51276:2012 | Practice for use of a polymethylmethacrylate dosimetry system |
ISO/ASTM 52303:2015 | Guide for absorbed-dose mapping in radiation processing facilities |
ISO/ASTM 51818:2013 | Practice for dosimetry in an electron beam facility for radiation processing at energies between 80 and 300 keV |
ISO/ASTM 51261:2013 | Practice for calibration of routine dosimetry systems for radiation processing |
ISO 14253-1:2017 | Geometrical product specifications (GPS) — Inspection by measurement of workpieces and measuring equipment — Part 1: Decision rules for verifying conformity or nonconformity with specifications |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO/ASTM 51275:2013 | Practice for use of a radiochromic film dosimetry system |
ISO/ASTM 51608:2015 | Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing at energies between 50 keV and 7.5 MeV |
ASTM E 2232 : 2016 : REDLINE | Standard Guide for Selection and Use of Mathematical Methods for Calculating Absorbed Dose in Radiation Processing Applications |
ISO/ASTM 52701:2013 | Guide for performance characterization of dosimeters and dosimetry systems for use in radiation processing |
ISO 11137-2:2013 | Sterilization of health care products — Radiation — Part 2: Establishing the sterilization dose |
ISO/ASTM 51607:2013 | Practice for use of the alanine-EPR dosimetry system |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
ISO/ASTM 51649:2015 | Practice for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV |
ISO/ASTM 51707:2015 | Guide for estimation of measurement uncertainty in dosimetry for radiation processing |
ISO/ASTM 52628:2013 | Standard practice for dosimetry in radiation processing |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO/ASTM 51631:2013 | Practice for use of calorimetric dosimetry systems for electron beam dose measurements and dosimetery system calibrations |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.