ACI 355.2 : 2007
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
QUALIFICATION OF POST-INSTALLED MECHANICAL ANCHORS IN CONCRETE AND COMMENTARY
Hardcopy , PDF
06-07-2019
English
01-01-2007
STANDARD:
Chapter 1 - Scope
Chapter 2 - Definitions and notation
Chapter 3 - Significance and use
Chapter 4 - General requirements
Chapter 5 - Requirements for test specimens,
installing anchors, and conducting
tests
Chapter 6 - Requirements for anchor identification
Chapter 7 - Reference tests
Chapter 8 - Reliability tests
Chapter 9 - Service-condition tests
Chapter 10 - Establishing anchor categories
Chapter 11 - Presenting anchor data
Chapter 12 - Requirements for independent testing and
evaluation agency
Chapter 13 - References
MANDATORY APPENDIXES:
Appendix A1 - Requirements for normalization of results
Appendix A2 - Requirements for establishing characteristic
capacities
Appendix A3 - Requirements for test members
COMMENTARY:
Chapter R1 - Scope
Chapter R2 - Definitions and notation
Chapter R3 - Significance and use
Chapter R4 - General requirements
Chapter R5 - Requirements for test specimens, installing
anchors, and conducting tests
Chapter R6 - Requirements for anchor identification
Chapter R7 - Reference tests
Chapter R8 - Reliability tests
Chapter R9 - Service-condition tests
Chapter R11 - Presenting anchor data
Chapter R13 - References
Appendix RA1 - Requirements for normalization of results
EXAMPLE EVALUATION OF A WEDGE-TYPE ANCHOR IN UNCRACKED
CONCRETE:
E1 - Anchor specifications
E2 - Test results
E3 - Evaluation
E4 - Establishing anchor category
E5 - Report of anchor data
Prescribes testing programs and evaluation requirements for post-installed mechanical anchors intended for use in concrete under the design provisions of ACI 318. Criteria are prescribed for determining whether anchors are acceptable for use in uncracked concrete only, or in cracked as well as uncracked concrete. Performance categories for anchors are established, as are the criteria for assigning anchors to each category.
Committee |
355
|
DocumentType |
Standard
|
Pages |
39
|
PublisherName |
American Concrete Institute
|
Status |
Superseded
|
SupersededBy |
CSA S832 : 2014 | SEISMIC RISK REDUCTION OF OPERATIONAL AND FUNCTIONAL COMPONENTS (OFCS) OF BUILDINGS |
ACI 551.2R : 2015 | DESIGN GUIDE FOR TILT-UP CONCRETE PANELS |
ACI 351.2R : 2010 | REPORT ON FOUNDATIONS FOR STATIC EQUIPMENT |
ASCE 7 05 : 2006 | MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES |
ASCE 7 10 : 2011 | MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES |
UFC 3-310-04 : Change 1 | UNIFIED FACILITIES CRITERIA - SEISMIC DESIGN FOR BUILDINGS |
ACI 369R : 2011 | GUIDE FOR SEISMIC REHABILITATION OF EXISTING CONCRETE FRAME BUILDINGS AND COMMENTARY |
ACI 318M : 2014 | BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318M-14) AND COMMENTARY (ACI 318RM-14) |
ACI 350M : 2006 | METRIC CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING CONCRETE STRUCTURES AND COMMENTARY |
ACI 350 : 2006 | CODE REQUIREMENTS FOR ENVIRONMENTAL ENGINEERING CONCRETE STRUCTURES AND COMMENTARY |
ACI PRC-506 : 2016 | GUIDE TO SHOTCRETE |
FM 1951,52,53 : 2016 | PIPE HANGER COMPONENTS FOR AUTOMATIC SPRINKLER SYSTEMS |
ACI MNL 3 : 0 | GUIDE TO THE CODE FOR ASSESSMENT, REPAIR, AND REHABILITATION OF EXISTING CONCRETE STRUCTURES |
ACI 355.4 : 2011 | QUALIFICATION OF POST-INSTALLED ADHESIVE ANCHORS IN CONCRETE AND COMMENTARY |
ACI 369.1M : 2017 | STANDARD REQUIREMENTS FOR SEISMIC EVALUATION AND RETROFIT OF EXISTING CONCRETE BUILDINGS (ACI 369.1M-17) AND COMMENTARY |
ACI 562 : 2016 | CODE REQUIREMENTS FOR ASSESSMENT, REPAIR, AND REHABILITATION OF EXISTING CONCRETE STRUCTURES AND COMMENTARY |
ASCE/SEI 41 13 : 2014 | SEISMIC EVALUATION AND RETROFIT OF EXISTING BUILDINGS |
API 1615 : 2011 | INSTALLATION OF UNDERGROUND PETROLEUM STORAGE SYSTEMS |
ACI 355.3R : 2011 | GUIDE FOR DESIGN OF ANCHORAGE TO CONCRETE: EXAMPLES USING ACI 318 APPENDIX D |
ACI 355.4M : 2011 | QUALIFICATION OF POST-INSTALLED ADHESIVE ANCHORS IN CONCRETE AND COMMENTARY (METRIC VERSION) |
N287.2-17 | Material requirements for concrete containment structures for nuclear power plants |
ACI 318 : 2014 | BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY |
API 1615 REDLINE : 2011 | INSTALLATION OF UNDERGROUND PETROLEUM STORAGE SYSTEMS |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ACI 318 : 2014 | BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY |
ACI 318R : 1995 | COMMENTARY ON BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE |
ASTM C 42/C 42M : 2016-10 | TEST METHOD FOR OBTAINING AND TESTING DRILLED CORES AND SAWED BEAMS OF CONCRETE |
ISO/IEC 17011:2004 | Conformity assessment General requirements for accreditation bodies accrediting conformity assessment bodies |
ASTM E 488 : 1996 | Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements |
ACI 224R : 2001 | CONTROL OF CRACKING OF CONCRETE STRUCTURES |
ANSI B212.15 : 1994(R2000) | CUTTING TOOLS - CARBIDE-TIPPED MASONRY DRILLS AND BLANKS FOR CARBIDE-TIPPED MASONRY DRILLS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.