AAMI TIR33 : 2005
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
STERILIZATION OF HEALTH CARE PRODUCTS - RADIATION STERILIZATION - SUBSTANTIATION OF A SELECTED STERILIZATION DOSE - METHOD VDMAX
Hardcopy , PDF
01-11-2017
English
01-01-2005
Glossary of equivalent standards
Committee representation
Introduction
1 Scope
1.1 Inclusions
1.2 Exclusions
2 Normative references
3 Terms and definitions
4 Definition and maintenance of product families for dose
setting, dose substantiation, and sterilization dose
auditing
4.1 General
4.2 Defining product families
4.3 Designating of product to represent a product family
for performance of a verification dose experiment or
sterilization dose audit
4.3.1 Product to represent a product family
4.3.2 Master product
4.3.3 Equivalent product
4.3.4 Simulated product
4.4 Maintaining product families
4.4.1 Periodic review
4.4.2 Modification to product and manufacturing process
4.4.3 Records
4.5 Effect of failure of establishment of sterilization
dose or of a sterilization dose audit on a product
family
5 Selection and testing of product for establishing and
verifying the sterilization dose
5.1 Nature of product
5.2 Sample item portion (SIP)
5.3 Manner of sampling
5.4 Microbiological testing
5.5 Irradiation
6 Method VD[max] - Substantiation of a selected sterilization
dose
6.1 Rationale
6.2 Procedure for Method VD[max] for multiple production
batches
6.2.1 General
6.2.2 Stage 1: Obtain samples of product
6.2.3 Stage 2: Determine average bioburden
6.2.4 Stage 3: Select sterilization dose
6.2.5 Stage 4: Obtain VD[max][SD]
6.2.6 Stage 5: Perform verification dose experiment
6.2.7 Stage 6: Interpretation of results
6.2.8 Confirmatory verification dose experiment
6.3 Procedure for Method VD[max] for a single production batch
6.3.1 Rationale
6.3.2 General
6.3.3 Stage 1: Obtain samples of product
6.3.4 Stage 2: Determine average bioburden
6.3.5 Stage 3: Selection of a sterilization dose
6.3.6 Stage 4: Obtain VD[max][SD]
6.3.7 Stage 5: Perform verification dose experiment
6.3.8 Stage 6: Interpretation of results
6.3.9 Confirmatory verification dose experiment
7 Auditing sterilization dose
7.1 Purpose and frequency
7.2 Procedure for auditing a sterilization dose
substantiated using Method VD[max]
7.2.1 General
7.2.2 Stage 1: Obtain samples of product
7.2.3 Stage 2: Determine average bioburden
7.2.4 Stage 3: Perform verification dose experiment
7.2.5 Stage 4: Interpretation of results
7.2.6 Confirmatory sterilization dose audit
8 Augmentation of a sterilization dose substantiated
using Method VD[max]
9 Worked examples
9.1 Substantiation of a selected Dose: SIP < 1.0 and
SIP = 1.0
9.2 Dose auditing and augmentation: Worked example
of a sterilization dose audit for a sterilization dose
substantiated using Method VD[max][25]
Annex A - VD[max][SD] look-up tables for verification doses,
SIP dose reduction factors, and dose augmentation
values
Bibliography
Specifies a method of substantiating a selected dose for a sterility assurance level (SAL) of 10[-6] for radiation sterilization of health care products.
Committee |
WG 02
|
DevelopmentNote |
Supersedes AAMI TIR27 (03/2006)
|
DocumentType |
Standard
|
Pages |
65
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
CAN/CSA-ISO/TS 16775:17 | Packaging for terminally sterilized medical devices — Guidance on the application of ISO 11607-1 and ISO 11607-2 (Adopted ISO technical specification 16775:2014, first edition, 2014-05-15) |
S.R. CEN ISO/TS 16775:2014 | PACKAGING FOR TERMINALLY STERILIZED MEDICAL DEVICES - GUIDANCE ON THE APPLICATION OF ISO 11607-1 AND ISO 11607-2 (ISO/TS 16775:2014) |
CEN ISO/TS 16775:2014 | Packaging for terminally sterilized medical devices - Guidance on the application of ISO 11607-1 and ISO 11607-2 (ISO/TS 16775:2014) |
PD CEN ISO/TS 16775:2014 | Packaging for terminally sterilized medical devices. Guidance on the application of ISO 11607-1 and ISO 11607-2 |
ANSI/AAMI/ISO TIR16775:2014 | PACKAGING FOR TERMINALLY STERILIZED MEDICAL DEVICES - GUIDANCE ON THE APPLICATION OF ISO 11607-1 AND ISO 11607-2 |
ISO/TS 16775:2014 | Packaging for terminally sterilized medical devices Guidance on the application of ISO 11607-1 and ISO 11607-2 |
UNI CEN ISO/TS 16775 : 2014 | PACKAGING FOR TERMINALLY STERILIZED MEDICAL DEVICES - GUIDANCE ON THE APPLICATION OF ISO 11607-1 AND ISO 11607-2 |
AAMI ISO 11137-2 : 2013 | STERILIZATION OF HEALTH CARE PRODUCTS - RADIATION - PART 2: ESTABLISHING THE STERILIZATION DOSE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.