AAMI ISO 8836 : 2015
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
SUCTION CATHETERS FOR USE IN THE RESPIRATORY TRACT
06-04-2024
01-01-2015
Glossary of equivalent standards
Committee representation
Background of ANSI/AAMI adoption
of ISO 8836:2014
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements for open
and closed suction catheters
5 Specific requirements for open
and closed suction catheters
6 Materials
7 Design
8 Performance requirements
9 Requirements for suction
catheters supplied sterile
10 Marking
Annex A (informative) - Rationale
Annex B (normative) - Test method
for security of attachment
Annex C (normative) - Measurement
of residual vacuum
Annex D (normative) - Method of
testing leakage
Annex E (informative) - Hazard
identification for risk
assessment
Bibliography
Describes requirements for suction catheters, including closed suction catheters, made of flexible materials and intended for use in suctioning of the respiratory tract.
Committee |
ISO/TC 121/SC 2
|
DocumentType |
Standard
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Withdrawn
|
Standards | Relationship |
ISO 8836:2014 | Identical |
ISO 11137-1:2006 | Sterilization of health care products Radiation Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 11607-2:2006 | Packaging for terminally sterilized medical devices Part 2: Validation requirements for forming, sealing and assembly processes |
ISO 15223-2:2010 | Medical devices — Symbols to be used with medical device labels, labelling, and information to be supplied — Part 2: Symbol development, selection and validation |
EN 15986:2011 | Symbol for use in the labelling of medical devices - Requirements for labelling of medical devices containing phthalates |
ISO 11135:2014 | Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
ISO 5356-1:2015 | Anaesthetic and respiratory equipment Conical connectors Part 1: Cones and sockets |
ISO 10079-1:2015 | Medical suction equipment Part 1: Electrically powered suction equipment |
ISO 5367:2014 | Anaesthetic and respiratory equipment — Breathing sets and connectors |
ISO 80601-2-12:2011 | Medical electrical equipment Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators |
EN 1041:2008+A1:2013 | Information supplied by the manufacturer of medical devices |
ISO 8185:2007 | Respiratory tract humidifiers for medical use Particular requirements for respiratory humidification systems |
ISO 10079-2:2014 | Medical suction equipment Part 2: Manually powered suction equipment |
ISO 5366-1:2000 | Anaesthetic and respiratory equipment Tracheostomy tubes Part 1: Tubes and connectors for use in adults |
ISO 10993-1:2009 | Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process |
ISO 5366-3:2001 | Anaesthetic and respiratory equipment Tracheostomy tubes Part 3: Paediatric tracheostomy tubes |
ISO 80369-7:2016 | Small-bore connectors for liquids and gases in healthcare applications Part 7: Connectors for intravascular or hypodermic applications |
ISO 10079-3:2014 | Medical suction equipment Part 3: Suction equipment powered from a vacuum or positive pressure gas source |
ISO 14155:2011 | Clinical investigation of medical devices for human subjects Good clinical practice |
ISO 5361:2016 | Anaesthetic and respiratory equipment — Tracheal tubes and connectors |
ISO/TR 11991:1995 | Guidance on airway management during laser surgery of upper airway |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
ISO 11607-1:2006 | Packaging for terminally sterilized medical devices Part 1: Requirements for materials, sterile barrier systems and packaging systems |
ISO 4135:2001 | Anaesthetic and respiratory equipment Vocabulary |
ISO 594-2:1998 | Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 2: Lock fittings |
ISO 15223-1:2016 | Medical devices Symbols to be used with medical device labels, labelling and information to be supplied Part 1: General requirements |
ISO 594-1:1986 | Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment Part 1: General requirements |
ASTM F 640 : 2012 : REDLINE | Standard Test Methods for Determining Radiopacity for Medical Use |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.