AAMI ISO 10993-1:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS
06-04-2024
01-01-2013
Glossary of equivalent standards
Committee representation
Background of ANSI/AAMI adoption of ISO 10993-1:2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General principles applying to biological evaluation
of medical devices
5 Categorization of medical devices
6 Biological evaluation process
7 Interpretation of biological evaluation data and overall
biological safety assessment
Annex A (informative) - Biological evaluation tests
Annex B (informative) - Guidance on the risk management process
Annex C (informative) - Suggested procedure for literature review
Bibliography
Specifies: - the general principles governing the biological evaluation of medical devices within a risk management process; - the general categorization of devices based on the nature and duration of their contact with the body; - the evaluation of existing relevant data from all sources; - the identification of gaps in the available data set on the basis of a risk analysis; - the identification of additional data sets necessary to analyze the biological safety of the medical device; - the assessment of the biological safety of the medical device.
Committee |
WG 01
|
DocumentType |
Standard
|
ProductNote |
Reconfirmed 2009
|
PublisherName |
Association for the Advancement of Medical Instrumentation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
ISO 10993-1:2009 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 10993-3:2014 | Biological evaluation of medical devices — Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity |
ISO 10993-4:2017 | Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood |
ISO 10993-16:2017 | Biological evaluation of medical devices — Part 16: Toxicokinetic study design for degradation products and leachables |
ISO/TS 10993-20:2006 | Biological evaluation of medical devices — Part 20: Principles and methods for immunotoxicology testing of medical devices |
ISO 10993-13:2010 | Biological evaluation of medical devices — Part 13: Identification and quantification of degradation products from polymeric medical devices |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO 10993-2:2006 | Biological evaluation of medical devices — Part 2: Animal welfare requirements |
ISO 7405:2008 | Dentistry Evaluation of biocompatibility of medical devices used in dentistry |
ISO 10993-14:2001 | Biological evaluation of medical devices — Part 14: Identification and quantification of degradation products from ceramics |
ISO 10993-18:2005 | Biological evaluation of medical devices Part 18: Chemical characterization of materials |
ISO/TS 10993-19:2006 | Biological evaluation of medical devices Part 19: Physico-chemical, morphological and topographical characterization of materials |
ISO 10993-10:2010 | Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization |
ISO 9004:2009 | Managing for the sustained success of an organization A quality management approach |
ISO 10993-11:2017 | Biological evaluation of medical devices — Part 11: Tests for systemic toxicity |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 10993-9:2009 | Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 10993-6:2016 | Biological evaluation of medical devices Part 6: Tests for local effects after implantation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.