AAMI ID26:2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

MEDICAL ELECTRICAL EQUIPMENT - PART 2: PARTICULAR REQUIREMENTS FOR THE SAFETY OF INFUSION PUMPS AND CONTROLLERS

Available format(s)

Hardcopy , PDF

Superseded date

06-04-2024

Superseded by

AAMI ID26 : 2004 : R2009

Language(s)

English

Published date

01-01-2013

Glossary of equivalent standards
Committee representation
Foreword
Introduction
AAMI deviations from IEC 60601-2-24:1998
SECTION ONE - GENERAL
1 Scope and object
2 Terminology and definitions
3 General requirements
5 Classification
6 Identification, marking, and documents
SECTION TWO - ENVIRONMENTAL CONDITIONS
10 Environmental conditions
SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
14 Requirements related to classification
17 Separation
19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS
SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
21 Mechanical strength
SECTION FIVE - PROTECTION AGAINST HAZARDS FROM UNWANTED OR
               EXCESSIVE RADIATION
36 Electromagnetic compatibility
SECTION SIX - PROTECTION AGAINST HAZARDS OF IGNITION OF
              FLAMMABLE ANESTHETIC MIXTURES
SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES
                AND OTHER SAFETY HAZARDS
44 Overflow, spillage, leakage, humidity, ingress of liquids,
   cleaning, sterilization, disinfection, and compatibility
47 Electrostatic charges
49 Interruption of the power supply
SECTION EIGHT - ACCURACY OF OPERATING DATA AND PROTECTION
                AGAINST HAZARDOUS OUTPUT
50 Accuracy of operating data
51 Protection against hazardous output
SECTION NINE - ABNORMAL OPERATION AND FAULT CONDITIONS:
               ENVIRONMENTAL TESTS
SECTION TEN - CONSTRUCTIONAL REQUIREMENTS
54 General
56 Components and general assembly
Appendix/Annex
L - References - Publications mentioned in this standard
AA - General guidance and rationale

Provides requirement for INFUSION PUMPS, INFUSION CONTROLLERS, SYRINGE PUMPS and PUMPS FOR AMBULATORY USE.

Committee
ID
DocumentType
Standard
Pages
68
ProductNote
Reconfirmed 2004
PublisherName
Association for the Advancement of Medical Instrumentation
Status
Superseded
SupersededBy

Standards Relationship
IEC 60601-2-24:2012 Identical

ISO 3744:2010 Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Engineering methods for an essentially free field over a reflecting plane
IEC 60521:1988 Class 0.5, 1 and 2 alternating-current watthour meters
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
ISO 7886-2:1996 Sterile hypodermic syringes for single use Part 2: Syringes for use with power-driven syringe pumps
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60801-1:1984 Electromagnetic compatibility for industrial-process measurement and control equipment. Part 1: General introduction
IEC 60601-1-3:2008+AMD1:2013 CSV Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
ISO 7864:2016 Sterile hypodermic needles for single use — Requirements and test methods
ISO 8536-4:2010 Infusion equipment for medical use Part 4: Infusion sets for single use, gravity feed
ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
IEC 60601-1-1:2000 Medical electrical equipment - Part 1-1: General requirements for safety - Collateral standard: Safety requirements for medical electrical systems
IEC 60601-1-4:1996+AMD1:1999 CSV Medical electrical equipment - Part 1-4: General requirements for safety - Collateral Standard: Programmable electrical medical systems
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV Sound level meters
IEC 60801-2:1991 Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements
IEC 60804:2000 Integrating-averaging sound level meters

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.