12/30265313 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN 124-6 - GULLY TOPS AND MANHOLE TOPS FOR VEHICULAR AND PEDESTRIAN AREAS - PART 6: GULLY TOPS AND MANHOLE TOPS MADE FROM POLYPROPYLENE (PP) OR POLYVINYL-CHLORIDE (PVC-U)
Hardcopy , PDF
31-07-2015
English
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Materials
6 Requirements
7 Testing
8 Assessment and verification of constancy
of performance - AVCP
9 Marking
Annex A (normative) - Test of deflection under load
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Products Regulation
Bibliography
BS EN 124-6.
Committee |
B/505/4/P1
|
DocumentType |
Draft
|
Pages |
41
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
PREN 124-6 : DRAFT 2012 | Identical |
ISO 4892-1:2016 | Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance |
ISO 580:2005 | Plastics piping and ducting systems — Injection-moulded thermoplastics fittings — Methods for visually assessing the effects of heating |
EN ISO 13229:2011 | Thermoplastics piping systems for non-pressure applications - Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings - Determination of the viscosity number and K-value (ISO 13229:2010) |
ISO 13229:2010 | Thermoplastics piping systems for non-pressure applications Unplasticized poly(vinyl chloride) (PVC-U) pipes and fittings Determination of the viscosity number and K-value |
EN ISO 4892-1:2016 | Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance (ISO 4892-1:2016) |
EN ISO 4892-3:2016 | Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps (ISO 4892-3:2016) |
ISO 1133-1:2011 | Plastics Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics Part 1: Standard method |
ISO 2507-1:1995 | Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test method |
ISO 3127:1994 | Thermoplastics pipes — Determination of resistance to external blows — Round-the-clock method |
EN 607:2004 | Eaves gutters and fittings made of PVC-U - Definitions, requirements and testing |
PREN 124-1 : DRAFT 2012 | GULLY TOPS AND MANHOLE TOPS FOR VEHICULAR AND PEDESTRIAN AREAS - PART 1: CLASSIFICATION, GENERAL DESIGN, PERFORMANCE AND TESTING REQUIREMENTS, TEST METHODS AND EVALUATION OF CONFORMITY |
EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
PREN 124-5 : DRAFT 2012 | GULLY TOPS AND MANHOLE TOPS FOR VEHICULAR AND PEDESTRIAN AREAS - PART 5: GULLY TOPS AND MANHOLE TOPS MADE OF COMPOSITE |
PREN 124-3 : DRAFT 2012 | GULLY TOPS AND MANHOLE TOPS FOR VEHICULAR AND PEDESTRIAN AREAS - PART 3: GULLY TOPS AND MANHOLE TOPS MADE FROM STEEL OR ALUMINIUM ALLOY |
EN ISO 1133-1:2011 | Plastics - Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics - Part 1: Standard method (ISO 1133-1:2011) |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
ISO 1183-1:2012 | Plastics Methods for determining the density of non-cellular plastics Part 1: Immersion method, liquid pyknometer method and titration method |
EN 12666-1:2005+A1:2011 | Plastics piping systems for non-pressure underground drainage and sewerage - Polyethylene (PE) - Part 1: Specifications for pipes, fittings and the system |
ISO 1183-2:2004 | Plastics Methods for determining the density of non-cellular plastics Part 2: Density gradient column method |
ISO 9001:2015 | Quality management systems — Requirements |
EN ISO 580:2005 | Plastics piping and ducting systems - Injection-moulded thermoplastics fittings - Methods for visually assessing the effects of heating (ISO 580:2005) |
ISO 11357-6:2008 | Plastics Differential scanning calorimetry (DSC) Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) |
ISO 178:2010 | Plastics Determination of flexural properties |
ISO 1043-1:2011 | Plastics — Symbols and abbreviated terms — Part 1: Basic polymers and their special characteristics |
PREN 124-4 : DRAFT 2012 | GULLY TOPS AND MANHOLE TOPS FOR VEHICULAR AND PEDESTRIAN AREAS - PART 4: GULLY TOPS AND MANHOLE TOPS MADE OF STEEL REINFORCED CONCRETE |
EN ISO 1183-1:2012 | Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method (ISO 1183-1:2012) |
EN ISO 1183-2:2004 | Plastics - Methods for determining the density of non-cellular plastics - Part 2: Density gradient column method (ISO 1183-2:2004) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.