12/30256417 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN 54-31 - FIRE DETECTION AND FIRE ALARM SYSTEM - PART 31: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF SMOKE, CARBON MONOXIDE AND OPTIONALLY HEAT SENSORS
Hardcopy , PDF
31-12-2014
English
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test and evaluation methods
6 Evaluation of conformity
Annex A (normative) - Smoke tunnel for smoke response
values
Annex B (normative) - Test aerosol for smoke response
value measurements
Annex C (normative) - Smoke measuring instruments
Annex D (normative) - Gas test chamber for CO response
threshold value and cross-sensitivity to chemical
agents
Annex E (normative) - Heat tunnel for heat response value
Annex F (normative) - Measuring instruments for CO
Annex G (informative) - Establishing exposure levels of
chemical agents
Annex H (normative) - Apparatus for dazzling test
Annex I (informative) - Apparatus for impact test
Annex J (normative) - Fire test room
Annex K (normative) - Open wood fire (TF1)
Annex L (normative) - Smouldering (pyrolysis) wood fire (TF2)
Annex M (normative) - Glowing smouldering cotton fire (TF3)
Annex N (normative) - Open plastics (polyurethane) fire (TF4)
Annex O (normative) - Liquid (heptane) fire (TF5)
Annex P (normative) - Low temperature black smoke (decalene)
liquid fire (TF8)
Annex Q (informative) - Information concerning the construction
of the smoke tunnel
Annex R (informative) - Information concerning the construction
of the gas test chamber
Annex S (informative) - Construction of the heat tunnel
Annex T (informative) - Information concerning test procedures
and requirements for response to slowly developing fires,
aging and contamination
Annex U (informative) - Information concerning the construction
of the measuring ionization chamber
Annex V (normative) - Additional requirements and test methods
for detectors with more than one smoke sensor
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Products Directive (89/106/EEC)
Bibliography
BS EN 54-31.
Committee |
FSH/12/2
|
DocumentType |
Draft
|
Pages |
113
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
PREN 54-31 : DRAFT 2012 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
ISO 209:2007 | Aluminium and aluminium alloys — Chemical composition |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 54-5:2017 | Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-2a:1976 | Supplement A - Basic environmental testing procedures - Part 2: Tests - Tests B: Dry heat |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
IEC 60068-2-56:1988 | Environmental testing - Part 2: Tests. Test Cb: Damp heat, steady state, primarily for equipment |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.