09/30204029 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN 61439-1 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1: GENERAL RULES
Hardcopy , PDF
30-11-2011
English
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
3.1 General terms
3.2 Constructional units of ASSEMBLIES
3.3 External design of ASSEMBLIES
3.4 Structural parts of ASSEMBLIES
3.5 Conditions of installation of ASSEMBLIES
3.6 Insulation characteristics
3.7 Protection against electric shock
3.8 Characteristics
3.9 Verification
3.10 Manufacturer/User
4 Symbols and abbreviations
5 Interface characteristics
5.1 General
5.2 Voltage ratings
5.3 Current ratings
5.4 Rated frequency (f[n])
5.5 Other characteristics
6 Information
6.1 ASSEMBLY designation marking
6.2 Documentation
6.3 Device and/or component identification
7 Service conditions
7.1 Normal service conditions
7.2 Special service conditions
7.3 Conditions during transport, storage and installation
8 Constructional requirements
8.1 Strength of materials and parts
8.2 Degree of protection provided by an ASSEMBLY
enclosure
8.3 Clearances and creepage distances
8.4 Protection against electric shock
8.5 Incorporation of switching devices and components
8.6 Internal electrical circuits and connections
8.7 Cooling
8.8 Terminals for external conductors
9 Performance requirements
9.1 Dielectric properties
9.2 Temperature rise limits
9.3 Short-circuit protection and short-circuit withstand
strength
9.4 Electromagnetic compatibility (EMC)
10 Design verification
10.1 General
10.2 Strength of materials and parts
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances
10.5 Protection against electric shock and integrity of
protective circuits
10.6 Incorporation of switching devices and components
10.7 Internal electrical circuits and connections
10.8 Terminals for external conductors
10.9 Dielectric properties
10.10 Verification of temperature rise
10.11 Short-circuit withstand strength
10.12 Electromagnetic compatibility (EMC)
10.13 Mechanical operation
11 Routine verification
11.1 General
11.2 Degree of protection of enclosures
11.3 Clearances and creepage distances
11.4 Protection against electric shock and integrity of
protective circuits
11.5 Incorporation of built-in components
11.6 Internal electrical circuits and connections
11.7 Terminals for external conductors
11.8 Mechanical operation
11.9 Dielectric properties
11.10 Wiring, operational performance and function
Annex A (normative) - Minimum and maximum cross-section of
copper conductors suitable for connection to terminals
for external conductors
Annex B (normative) - Method of calculating the cross-sectional
area of protective conductors with regard to thermal
stresses due to currents of short duration
Annex C (informative) - Items subject to agreement between the
assembly manufacturer and the user
Annex D (informative) - Design verification
Annex E (informative) - Rated diversity factor
E.1 General
E.2 Rated diversity factor of an ASSEMBLY
E.3 Rated diversity factor of a group of outgoing circuits
E.4 Rated diversity factor and intermittent duty
Annex F (normative) - Measurement of clearances and creepage
distances
F.1 Basic principles
F.2 Use of ribs
Annex G (normative) - Correlation between the nominal
voltage of the supply system and the rated impulse
withstand voltage of the equipment
Annex H (informative) - Operating current and power loss of
copper conductors
J.1 General
J.2 Terms and definitions
Annex K (normative) - Protection by electrical separation
K.1 General
K.2 Electrical separation
K.3 Class II equipment or equivalent insulation
Annex L (informative) - Clearances and creepage distances
for North American region
Annex M (informative) - North American temperature rise limits
Annex N (informative) - Operating current and power loss of
bare copper busbars
Annex O (informative) - Guidance on temperature rise verification
Annex P (normative) - A method for assessing the short-circuit
withstand strength of the main circuits of an ASSEMBLY
P.1 General
P.2 Definitions
P.3 Method of interpolation
P.4 Conditions for application
Bibliography
BS EN 61439-1
Committee |
PEL/17/3
|
DocumentType |
Draft
|
Pages |
131
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC TR 61912-1:2007 | Low-voltage switchgear and controlgear - Overcurrent protective devices - Part 1: Application of short-circuit ratings |
IEC 60038:2009 | IEC standard voltages |
IEC 60227-4:1992+AMD1:1997 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 4: Sheathed cables for fixed wiring |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60073:2002 | Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC TR 61912-2:2009 | Low-voltage switchgear and controlgear - Over-current protective devices - Part 2: Selectivity under over-current conditions |
IEC 60227-3:1993+AMD1:1997 CSV | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 3: Non-sheathed cables for fixed wiring |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
ISO 4628-3:2016 | Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 3: Assessment of degree of rusting |
IEC 61346-1:1996 | Industrial systems, installations and equipment and industrial products - Structuring principles and reference designations - Part 1: Basic rules |
IEC 60865-1:2011 | Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods |
IEC 60447:2004 | Basic and safety principles for man-machine interface, marking and identification - Actuating principles |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC 60245-4:2011 | Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables |
IEC 60099-1:1991+AMD1:1999 CSV | Surge arresters - Part 1: Non-linear resistor type gapped surge arresters for a.c. systems |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC TR 61000-3-7:2008 | Electromagnetic compatibility (EMC) - Part 3-7: Limits - Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 62208:2011 | Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
ISO 2409:2013 | Paints and varnishes Cross-cut test |
IEC TR 61000-3-6:2008 | Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
ISO 178:2010 | Plastics Determination of flexural properties |
IEC 60445:2017 | Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 61346-2:2000 | Industrial systems, installations and equipment and industrial products - Structuring principles and reference designations - Part 2: Classification of objects and codes for classes |
IEC 60092-302:1997 | Electrical installations in ships - Part 302: Low-voltage switchgear and controlgear assemblies |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
DIN 43671:1975-12 | COPPER BUS BARS; DESIGN FOR CONTINUOUS CURRENT |
IEC TR 60890:2014 | A method of temperature-rise verification of low-voltage switchgear and controlgear assemblies by calculation |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.