08/30188440 DC : 0
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
BS EN 1911 - STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF GASEOUS CHLORIDES EXPRESSED AS HCL - STANDARD REFERENCE METHOD
Hardcopy , PDF
31-08-2010
English
Foreword
1 Scope
2 Normative references
3 Definitions
4 Sampling
4.1 Sampling principle
4.2 Sampling strategy
4.3 Sampling equipment
4.4 Sampling procedure
5 Analysis
5.1 Introduction
5.2 Reagents and samples to be analysed
5.3 Silver titration: potentiometric method
5.4 Mercuric-thiocyanate spectrophotometry
5.5 Ion-exchange chromatography
6 Expression of results
7 Determination of the characteristics of the method:
sampling and analysis
7.1 General
7.2 Relevant performance characteristics of the method and
performance criteria
7.3 Establishment of the uncertainty budget
8 Measurement report
Annex A (informative) - Examples of absorbers
Annex B (informative) - Comparison between mercuric-thiocyanate
spectrophotometry and ion exchange chromatography
method (methods B and C)
Annex C (informative) - Example of assessment of compliance or
reference method for chlorides with requirements on
emission measurements
Annex D (informative) - Performance characteristics of the whole
measurement method
Bibliography
BS EN 1911
Committee |
EH/2/1
|
DocumentType |
Draft
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
PREN 1911 : DRAFT 2008 | Identical |
CEN/TS 14793:2005 | Stationary source emission - Intralaboratory validation procedure for an alternative method compared to a reference method |
ISO 5725-6:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values |
EN 15259:2007 | Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report |
ISO 10304-1:2007 | Water quality Determination of dissolved anions by liquid chromatography of ions Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate |
EN ISO 20988:2007 | Air quality - Guidelines for estimating measurement uncertainty (ISO 20988:2007) |
EN 13284-1:2017 | Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method |
EN ISO 14956:2002 | Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002) |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
ISO 3696:1987 | Water for analytical laboratory use — Specification and test methods |
EN ISO 3696:1995 | Water for analytical laboratory use - Specification and test methods (ISO 3696:1987) |
EN ISO 10304-1:2009 | Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate (ISO 10304-1:2007) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.