ISO 18362:2016
Current
The latest, up-to-date edition.
Manufacture of cell-based health care products — Control of microbial risks during processing
English
15-01-2016
ISO 18362:2016 specifies the minimum requirements for, and provides guidance on, a risk-based approach for the processing of cell-based health care products (CBHPs) requiring control of viable and non-viable microbial contamination. It is applicable both to CBHPs labelled 'sterile' and to CBHPs not labelled 'sterile'.
ISO 18362:2016 is not applicable to:
- procurement and transport of cell-based starting material used in processing of a CBHP,
- cell banking,
- control of genetic material,
- control of non-microbial product contamination,
- in vitro diagnostics (IVDs), or
- natural medicines.
EXAMPLE Vitamins and minerals, herbal remedies, homoeopathic medicines, traditional medicines such as traditional Chinese medicines, probiotics, other products such as amino acids and essential fatty acids.
ISO 18362:2016 does not define biosafety containment requirements.
ISO 18362:2016 does not replace national or regional regulations that apply to the manufacture and quality control of a CBHP.
| Committee |
ISO/TC 198
|
| DevelopmentNote |
Supersedes ISO/DIS 18362. (01/2016)
|
| DocumentType |
Standard
|
| Pages |
32
|
| PublisherName |
International Organization for Standardization
|
| Status |
Current
|
| Standards | Relationship |
| DS ISO 18362 : 2016 | Identical |
| NEN ISO 18362 : 2016 | Identical |
| BS ISO 18362:2016 | Identical |
| ABNT NBR ISO 18362:2023 | Identical |
| ASTM F 3223 : 2017 | Standard Guide for Characterization and Assessment of Tissue Engineered Medical Products (TEMPs) for Knee Meniscus Surgical Repair and/or Reconstruction |
| ISO 13408-7:2012 | Aseptic processing of health care products — Part 7: Alternative processes for medical devices and combination products |
| AAMI TIR37 : 2013 | STERILIZATION OF HEALTH CARE PRODUCTS - RADIATION - GUIDANCE ON STERILIZATION OF BIOLOGICS AND TISSUE-BASED PRODUCTS |
| ISO 14160:2011 | Sterilization of health care products — Liquid chemical sterilizing agents for single-use medical devices utilizing animal tissues and their derivatives — Requirements for characterization, development, validation and routine control of a sterilization process for medical devices |
| ISO 11135:2014 | Sterilization of health-care products — Ethylene oxide — Requirements for the development, validation and routine control of a sterilization process for medical devices |
| ISO 13408-2:2003 | Aseptic processing of health care products — Part 2: Filtration |
| ISO 11737-1:2006 | Sterilization of medical devices — Microbiological methods — Part 1: Determination of a population of microorganisms on products |
| ISO/TS 17665-2:2009 | Sterilization of health care products — Moist heat — Part 2: Guidance on the application of ISO 17665-1 |
| ISO 13485:2016 | Medical devices — Quality management systems — Requirements for regulatory purposes |
| ISO 14937:2009 | Sterilization of health care products — General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
| CFR 21(PTS800-1299) : 0 | FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 800-1299 |
| ISO/TR 14969:2004 | Medical devices — Quality management systems — Guidance on the application of ISO 13485: 2003 |
| ISO 25424:2009 | Sterilization of medical devices — Low temperature steam and formaldehyde — Requirements for development, validation and routine control of a sterilization process for medical devices |
| ISO 13022:2012 | Medical products containing viable human cells — Application of risk management and requirements for processing practices |
| ISO 9004:2009 | Managing for the sustained success of an organization — A quality management approach |
| ISO 13408-1:2008 | Aseptic processing of health care products — Part 1: General requirements |
| ISO 20857:2010 | Sterilization of health care products — Dry heat — Requirements for the development, validation and routine control of a sterilization process for medical devices |
| ISO/TS 11139:2006 | Sterilization of health care products — Vocabulary |
| ISO 29463-1:2017 | High efficiency filters and filter media for removing particles from air — Part 1: Classification, performance, testing and marking |
| ISO 14644-4:2001 | Cleanrooms and associated controlled environments — Part 4: Design, construction and start-up |
| ISO 14971:2007 | Medical devices — Application of risk management to medical devices |
| ISO 14161:2009 | Sterilization of health care products — Biological indicators — Guidance for the selection, use and interpretation of results |
| ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.