UTEC 93 533 : 2009
Current
The latest, up-to-date edition.
CABLES WITH POLYVINYL CHLORIDE INSULATION AND POLYVINYL CHLORIDE SHEATH FOR CABLING AND INDOOR INSTALLATION OF TRANSMISSION EQUIPMENTS - GENERIC SPECIFICATION
12-01-2013
SECTION 1 - GENERALITES
1 INTRODUCTION
2 NORMES DE RÉFÉRENCE
3 ASSURANCE DE LA QUALITÉ
SECTION 2 - CONSTRUCTION DU CABLE
4 CONDUCTEUR
5 ENVELOPPE ISOLANTE
6 ÉLÉMENTS DE CABLAGE
7 MODE DE CABLAGE
8 PAIRES DE RÉSERVE
9 CODE DES COULEURS
10 REVETEMENT ET ÉCRAN DE L'AME
11 GAINE
12 FILIN DE DÉCHIREMENT
13 CABLE EN ÉTAT DE LIVRAISON
14 LIVRAISON
SECTION 3 - PRESCRIPTIONS MÉCANIQUES
15 CONDUCTEUR
16 ENVELOPPE ISOLANTE
17 GAINES
SECTION 4 - PRESCRIPTIONS THERMIQUES ET D'ENVIRONNEMENT
18 ENVELOPPE ISOLANTE
19 GAINE
20 COMPORTEMENT AU FEU
SECTION 5 - PRESCRIPTIONS ÉLECTRIQUES
21 RÉSISTANCE ÉLECTRIQUE DU CONDUCTEUR
22 RIGIDITÉ DIÉLECTRIQUE
23 RÉSISTANCE D'ISOLEMENT
ANNEXE A - CODE DES COULEURS PRÉFÉRENTIEL
ANNEXE B - CODE DES COULEURS DES ENVELOPPES ISOLANTES DES
CABLES ASSEMBLÉS NE
DÉPASSANT PAS 60 ÉLÉMENTS
ANNEXE C - RIGIDITÉ SOUS CONTRAINTES MÉCANIQUES
Le présent document définit les conditions techniques auxquelles doivent répondre l'ensemble des câbles à isolation et gainage en polychlorure de vinyle destinés aux installations intérieures des équipements de transmission.
DevelopmentNote |
Indice de classement: C93-533U. (02/2009) Supersedes NFC 93 533. (04/2009)
|
DocumentType |
Standard
|
PublisherName |
Association Francaise de Normalisation
|
Status |
Current
|
Supersedes |
UTEC 93 534-1 : 2009 | CABLES WITH POLYVINYL CHLORIDE INSULATION AND POLYVINYL CHLORIDE SHEATH FOR CABLING AND INDOOR INSTALLATION OF TRANSMISSION EQUIPMENTS - DETAIL SPECIFICATION SERIES 282 FOR WIRES AND CABLES |
UTEC 93 534-2 : 2009 | CABLES WITH POLYVINYL CHLORIDE INSULATION AND POLYVINYL CHLORIDE SHEATH FOR CABLING AND INDOOR INSTALLATION OF TRANSMISSION EQUIPMENTS - DETAIL SPECIFICATION SERIES 281 FOR JUMPERS |
UTEC 93 534-3 : 2009 | CABLES WITH POLYVINYL CHLORIDE INSULATION AND POLYVINYL CHLORIDE SHEATH FOR CABLING AND INDOOR INSTALLATION OF TRANSMISSION EQUIPMENTS - DETAIL SPECIFICATION SERIES 282 FOR SCREENED ONE PAIR CABLES |
NF EN 50289-3-8 : 2017 | COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-8: MECHANICAL TEST METHODS - ABRASION RESISTANCE OF CABLE SHEATH MARKINGS |
IEC 60028:1925 | International standard of resistance for copper |
2006/95/EC : 2006 | DIRECTIVE 2006/1995/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 12 DECEMBER 2006 ON THE HARMONISATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS (CODIFIED VERSION) (TEXT WITH EEA RELEVANCE) |
NFC 32 050 : 1990 | INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - METAL SHEATHED CABLES - RULES |
IEC 60304:1982 | Standard colours for insulation for low-frequency cables and wires |
NF EN 50289-1-4 : 2001 | COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-4: ELECTRICAL TEST METHODS - INSULATION RESISTANCE |
NF EN 50290-2-21 : 2002 AMD 1 2008 | COMMUNICATION CABLES - PART 2-21: COMMON DESIGN RULES AND CONSTRUCTION - PVC INSULATION COMPOUNDS |
NF EN 50289-3-4 : 2001 | COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-4: MECHANICAL TEST METHODS - TENSILE STRENGTH, ELONGATION AND SHRINKAGE OF INSULATION AND SHEATH |
NF EN 50289-3-7 : 2001 | COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-7: MECHANICAL TEST METHODS - ABRASION RESISTANCE OF THE CABLE SHEATH |
NF EN 50289-3-2 : 2001 | COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-2: MECHANICAL TEST METHODS - TENSILE STRENGTH AND ELONGATION FOR CONDUCTOR |
NFX 08 002 : 1983 FD | LIMITED COLLECTION OF COLOURS - DESIGNATION AND CATALOGUE OF CCR COLOURS - SECONDARY STANDARDS |
NFC 31 111 : 1992 | WIRES FOR ELECTRICAL MACHINERY AND APPARATUS - ROUND BARE ANNEALED COPPER WIRE - CHARACTERISTICS |
NF EN 50290-4-1 : 2015 | COMMUNICATION CABLES - PART 4-1: GENERAL CONSIDERATIONS FOR THE USE OF CABLES - ENVIRONMENTAL CONDITIONS AND SAFETY ASPECTS |
IEC TR 60344:2007 | Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide |
NF EN 50289-3-9 : 2001 | COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 3-9: MECHANICAL TEST METHODS - BENDING TESTS |
NF EN 60332-2-2 : 2005 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL INSULATED WIRE OR CABLE - PROCEDURE FOR DIFFUSION FLAME |
NF EN 60811 1-1 : 96 AMD 1 2001 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 1: MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES |
NF EN 60332-2-1 : 2005 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-1: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL INSULATED WIRE OR CABLE - APPARATUS |
NF EN 50289-1-2 : 2001 | COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-2: ELECTRICAL TEST METHOD - DC RESISTANCE |
NF EN 50290-2-22 : 2002 AMD 1 2008 | COMMUNICATION CABLES - PART 2-22: COMMON DESIGN RULES AND CONSTRUCTION - PVC SHEATHING COMPOUNDS |
UTEC 32 063-3 : 2009 | TOXICITY OF COMBUSTION GASES OF HALOGEN FREE MATERIALS FOR SHEATH USED IN COMMUNICATION CABLES WITH PARTICULAR FIRE RELATED PROPERTIES |
NF EN 50289-1-3 : 2001 | COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 1-3: ELECTRICAL TEST METHOD - DIELECTRIC STRENGTH |
NFC 32 062-1 : 1995 | ELECTRONIC COMPONENTS - LOW CORROSIVE MATERIALS FOR INSULATION AND SHEATH USED IN COMMUNICATION CABLES WITH PARTICULAR FIRE RELATED PROPERTIES |
NF EN 50290-2-1 : 2005 | COMMUNICATION CABLES - PART 2-1: COMMON DESIGN RULES AND CONSTRUCTION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-