UNI EN ISO 12567-1 : 2010
Current
The latest, up-to-date edition.
THERMAL PERFORMANCE OF WINDOWS AND DOORS - DETERMINATION OF THERMAL TRANSMITTANCE BY THE HOT-BOX METHOD - PART 1: COMPLETE WINDOWS AND DOORS
25-11-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Principle
5 Requirements for test specimens and apparatus
6 Test procedure
7 Test report
Annex A (normative) - Environmental temperatures
Annex B (normative) - Linear thermal transmittance of the
edge zone
Annex C (informative) - Design of calibration transfer standard
Annex D (informative) - Example of calibration test and
measurement of window specimen
Annex E (informative) - Analytical calibration procedure using
heat balance equations
Annex F (informative) - Uncertainty analysis for hot boxes
Bibliography
Describes a method to measure the thermal transmittance of a door or window system. Also applies to all effects of frames, sashes, shutters, blinds, screens, panels, door leaves and fittings.
DocumentType |
Standard
|
PublisherName |
Ente Nazionale Italiano di Unificazione (UNI)
|
Status |
Current
|
Supersedes |
Standards | Relationship |
BS EN ISO 12567-1:2010 | Identical |
NF EN ISO 12567-1 : 2013 | Identical |
I.S. EN ISO 12567-1:2010 | Identical |
NEN EN ISO 12567-1 : 2010 C1 2010 | Identical |
ONORM EN ISO 12567-1 : 2010 AC 2010 | Identical |
NBN EN ISO 12567-1 : 2010 COR 2010 | Identical |
ISO 12567-1:2010 | Identical |
NS EN ISO 12567-1 : 2010 AC 2010 | Identical |
SN EN ISO 12567-1 : 2010 | Identical |
DIN EN ISO 12567-1:2010-12 | Identical |
EN ISO 12567-1:2010 | Identical |
UNE-EN ISO 12567-1:2002 | Identical |
ISO 10211:2017 | Thermal bridges in building construction — Heat flows and surface temperatures — Detailed calculations |
ASTM C 518 : 2017 : REDLINE | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus |
EN 12898:2001 | Glass in building - Determination of the emissivity |
ISO 8302:1991 | Thermal insulation — Determination of steady-state thermal resistance and related properties — Guarded hot plate apparatus |
ISO 8301:1991 | Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter apparatus |
ISO 140-1:1997 | Acoustics Measurement of sound insulation in buildings and of building elements Part 1: Requirements for laboratory test facilities with suppressed flanking transmission |
ISO 9288:1989 | Thermal insulation — Heat transfer by radiation — Physical quantities and definitions |
ASTM C 1363 : 2011 : REDLINE | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus |
ISO 10077-1:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General |
ASTM E 1423 : 2014 : REDLINE | Standard Practice for Determining Steady State Thermal Transmittance of Fenestration Systems |
ISO 8990:1994 | Thermal insulation — Determination of steady-state thermal transmission properties — Calibrated and guarded hot box |
IEC 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
ISO 7345:1987 | Thermal insulation Physical quantities and definitions |
ASTM C 1199 : 2014 : REDLINE | Standard Test Method for Measuring the Steady-State Thermal Transmittance of Fenestration Systems Using Hot Box Methods |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.