UNE-HD 60364-7-721:2011
Superseded
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Low-voltage electrical installations - Part 7-721: Requirements for special installations or locations - Electrical installations in caravans and motor caravans
Available format(s)
Hardcopy , PDF
Superseded date
18-04-2020
Superseded by
Language(s)
Spanish, Castilian, English
Published date
19-04-2011
Publisher
Committee |
CTN 202/SC 64
|
DevelopmentNote |
Supersedes UNE 20460-7-754. (04/2012)
|
DocumentType |
Standard
|
Pages |
26
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
HD 60364-7-721:2009/corrigendum:2010 | Identical |
HD 60364-7-721:2009 | Identical |
IEC 60364-7-721:2017 | Identical |
IEC 60038:2009 | IEC standard voltages |
IEC 60364-7-717:2009 | Low-voltage electrical installations - Part 7-717: Requirements for special installations or locations - Mobile or transportable units |
IEC 60332-1-3:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for determination of flamingdroplets/particles |
IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
ISO 11446:2004 | Road vehicles Connectors for the electrical connection of towing and towed vehicles 13-pole connectors for vehicles with 12 V nominal supply voltage |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 60335-2-29:2004/A2:2010 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 2-29: PARTICULAR REQUIREMENTS FOR BATTERY CHARGERS |
EN 60332-1-2:2004/A11:2016 | TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR 1 KW PRE-MIXED FLAME (IEC 60332-1-2:2004/A1:2015) |
HD 472 S1:1989/AC:2013 | NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS |
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules |
HD 60364-5-51:2009/A12:2017 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES |
HD 60364-7-701:2007/A12:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-701: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - LOCATIONS CONTAINING A BATH OR SHOWER |
EN 61009-1:2012/A12:2016 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCBOS) - PART 1: GENERAL RULES |
IEC 60364-7-701:2006 | Low-voltage electrical installations - Part 7-701: Requirements for special installations or locations - Locations containing a bath or shower |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISO 6309:1987 | Fire protection — Safety signs |
IEC 60335-2-29:2016 | Household and similar electrical appliances - Safety - Part 2-29: Particular requirements for battery chargers |
ISO 1724:2003 | Road vehicles Connectors for the electrical connection of towing and towed vehicles 7-pole connector type 12 N (normal) for vehicles with 12 V nominal supply voltage |
EN ISO 11446:2004 | Road vehicles - Connectors for the electrical connection of towing and towed vehicles - 13-pole connectors for vehicles with 12 V nominal supply voltage (ISO 11446:2004) |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
EN 61008-1:2012/A12:2017 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKERS WITHOUT INTEGRAL OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR USES (RCCBS) - PART 1: GENERAL RULES (IEC 61008-1:2010, MODIFIED) |
IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60947-2:2017 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
HD 60364-7-717:2010/AC:2014 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-717: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MOBILE OR TRANSPORTABLE UNITS |
EN 60309-2:1999/A2:2012 | PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 2: DIMENSIONAL INTERCHANGEABILITY REQUIREMENTS FOR PIN AND CONTACT-TUBE ACCESSORIES (IEC 60309-2:1999/A2:2012) |
IEC 60309-2:1999+AMD1:2005+AMD2:2012 CSV | Plugs, socket-outlets and couplers for industrial purposes - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories |
ISO 3732:2003 | Road vehicles Connectors for the electrical connection of towing and towed vehicles 7-pole connector type 12 S (supplementary) for vehicles with 12 V nominal supply voltage |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.