UNE EN 61965 : 2002 ERRATUM 2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
MECHANICAL SAFETY OF CATHODE RAY TUBES
Hardcopy , PDF
01-10-2006
English
28-11-2002
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirements
4.1 Corrosion protection
4.2 Mechanical damage
4.3 Handling
4.4 Film-coated CRTs
5 Environmental conditioning
5.1 Standard atmospheric conditions for testing
5.2 Preconditioning
5.3 Thermal conditioning
6 Sampling
6.1 Sampling plans
6.2 Sample numbers
6.3 Compliance
7 Test preparation and set-up
7.1 Scratch patterns
7.2 Barriers
7.3 Mounting
7.4 Mounting position
8 Testing of large CRTs
8.1 Mechanical strength (ball impact test)
8.2 Implosion test (missile)
8.3 Implosion test (thermal shock)
8.4 High-energy impact test
9 Testing of small CRTs
9.1 Mechanical strength (ball impact test)
9.2 Implosion test (high ball)
9.3 Implosion test (thermal shock)
9.4 High-energy impact test
10 Testing of prestressed banded CRTs with protective film
10.1 General
10.2 Film scoring pattern for CRTs with protective film
10.3 Peel test
10.4 Immersion test
11 Marking
12 Application notes for pre-stressed banded CRTs with
protective film
13 Normative requirements for the use of tables 1 and 2
(prestressed banded CRTs)
13.1 Sampling plan I: New construction
13.2 Sampling plan II: New construction with known resin or tape
13.3 Sampling plan III: Tension band and alternative tension band
13.4 Sampling plan IV: Alternative construction
14 Normative requirements for the use of tables 3 and 4
(prestressed banded with protective film)
14.1 Sampling plan I: New construction
14.2 Sampling plan II: New construction with known resin,
tape, film or adhesive
14.3 Sampling plan III: Alternative tension band
14.4 Sampling plan IV: Alternative construction
15 Alternative thermal conditioning for use with Tables 3 and 4
(prestressed banded with protective film)
15.1 Additional peel force requirements where alternative
thermal conditioning is to be performed
15.2 Tensile strength test where alternative thermal
conditioning is to be performed
16 Normative requirements for the use of Tables 6 and 7
(bonded frame CRTs)
16.1 Sampling plan I: New construction
16.2 Sampling plan II: Alternative construction
17 Normative requirements for the use of Tables 8 and 9
(laminated CRTs)
17.1 Sampling plan I: New construction
17.2 Sampling plan II: Alternative construction
Annex A (informative) Background to the development of this
standard
A.1 Mechanical strength test
A.2 Implosion test
A.3 Small CRTs (76 mm to 160 mm diagonal)
A.4 Evaluation time
Annex B (informative) Velocity and potential force of glass
particles expelled from a CRT subjected to a
ball impact - Ballistic and statistical
calculations
B.1 Introduction
B.2 Analysis without friction
B.3 Analysis with friction
B.4 Potential threat
B.5 Conclusions
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications û
Applies to cathode ray tubes and cathode ray tube assemblies which are intended for use as components in apparatus and which have integral protection with respect to the effects of implosion.
Committee |
CTN 209
|
DocumentType |
Standard
|
Pages |
0
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Withdrawn
|
Standards | Relationship |
BS EN 61965:2003 | Identical |
NBN EN 61965 : 2005 | Identical |
SN EN 61965 : 2003 | Identical |
DIN EN 61965 : 2004 | Identical |
EN 61965:2003 | Identical |
NF EN 61965 : 2004 | Identical |
IEC 61965:2003 | Identical |
I.S. EN 61965:2003 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.