Foreword
Introduction
1 Scope
2 Glossary
3 Units of measurement
4 Components
Construction - mechanical
5 General
Construction - electrical
6 General
7 Servicing and adjustment
8 Electrical enclosures
9 Field wiring connections
10 Internal wiring
11 Separation of circuits
12 Mounting of components
13 Motors and motor overcurrent or overload protection
14 Overcurrent protection of high-voltage control-
circuit conductors
15 Overcurrent protection of transformers
16 Switches and controllers
17 Capacitors
18 Electrical insulating material
19 Spacings - high-voltage circuits
20 Spacings - low-voltage circuits
21 Accessibility of uninsulated live parts
22 Bonding for grounding
Construction - burner assemblies
23 General
24 Controls
25 Combustion air controls
26 Primary safety controls
27 Ignition systems
28 Fittings and piping
29 Valves and regulators
30 Combination gas-oil burner assemblies
Construction - boilers, furnaces and heaters
31 General
32 Accessibility
33 Baffles
34 Burner equipment
35 Operating controls
36 Limit controls
37 Installation of external controls and fittings on
boilers
38 Flue dampers, draft regulators, and draft hoods
39 Bleeds and vents
40 Bases
41 Heating surfaces and combustion chambers
42 Radiation shields
43 Materials in air handling compartments
44 Casings
45 Fuel lines and components
46 Flue collars
47 Air filters
Performance
48 General
49 Test installations
50 Test methods
51 Burner assembly tests
52 Operation tests
53 Temperature tests
54 Low water cutoff of boilers - test no. 17A
55 Short-circuit - test no. 18
56 Overload test, high-voltage transformers - test no.
18A
57 Burnout test, high-voltage transformers - test no.
18B
58 Dielectric voltage-withstand test - test no. 19
59 Draft hood equipped devices
60 Flame test
61 Strain relief test
Outdoor-use equipment
62 General
63 Enclosures
64 Field wiring connections
65 Wiring
66 Outdoor-use equipment tests
67 Gaskets
68 Chromic acid dropping test - no. 26
Manufacturing and production tests
69 General
Marking and instructions
70 Marking
71 Instructions
Appendix
A Standards for components
This revision of UL 795 dated September 29, 2020 includes editorial corrections to an equation in paragraph 56.1.5 and a table reference in paragraph 43.2.
DevelopmentNote |
NEW CHILD REV 1 2020 IS NOW ADDED
New child REV 3 2022 is added |
DocumentType |
Standard
|
Pages |
0
|
ProductNote |
NEW CHILD REV 1 2020 IS NOW ADDED
New child REV 3 2022 is added |
PublisherName |
Underwriters Laboratories
|
Status |
Superseded
|
SupersededBy |
These requirements apply to factory-built gas appliances having inputs of more than 400,000 Btu per hour, per individual combustion chamber which require flame failure and other precautions and which are intended primarily for commercial and industrial installation.
ANSI FC 1 : 2012 | STATIONARY FUEL CELL POWER SYSTEMS |
CSA HPIT 2-2017 | Dispensing systems and components for fueling hydrogen powered industrial trucks |
ICC 2009 INT. RESI.CODE & COMM.-I1 : 2009 | 2009 INTERNATIONAL RESIDENTIAL CODE & COMMENTARY - VOLUME 2: CHAPTERS 12 TO 44 |
MIL-B-18897 Revision F:1990 | BOILERS, STEAM AND HOT WATER, WATERTUBE (STRAIGHT BARE AND FINNED TUBE), CAST IRON AND FIREBOX, PACKAGED TYPE (40,000 TO 35,000 BTU/HR THERMAL OUTPUT CAPACITY) |
MIL-B-23170 Revision A:1978 | BOILERS, STEAM, HIGH PRESSURE WATER TUBE, PACKAGED TYPE (5,000 TO 50,000 POUNDS PER HOUR, FIRED BY COAL, OIL, GAS OR COMBINATION OIL/GAS) |
MIL-B-18796 Revision F:1984 | BURNERS, SINGLE: OIL, GAS, AND GAS-OIL COMBINATION FOR PACKAGED BOILERS (320,001 TO 125,000,000 BTU/HR THERMAL OUTPUT CAPACITY) |
MIL-B-28684 Base Document:1990 | BOILERS, STEAM AND HOT WATER, VERTICAL FIRETUBE AND VERTICAL TUBELESS, PACKAGED TYPE (40,000 TO 10,000,000 BTU/HR THERMAL OUTPUT CAPACITY) |
F-B-2910 Base Document:1998 | BURNERS, SINGLE: OIL, GAS, AND GAS-OIL COMBINATION FOR PACKAGED BOILERS (320,001 TO 125, 000,000 BTU/HR THERMAL OUTPUT CAPACITY) |
MIL-B-17228 Revision F:1990 | BOILERS, STEAM AND HOT WATER, WATERTUBE (COIL AND SERPENTINE), PACKAGED TYPE (40,000 TO 10,000,000 BTU/HR THERMAL OUTPUT CAPACITY) |
ICC IFGC CODE AND COMMENTARY : 2015 | IFGC® Code and Commentary |
ANSI/CSA NGV 5.1-2016 (R2020) | Residential fueling appliances |
CSA NGV 5.1 : 2016 | RESIDENTIAL FUELING APPLIANCES |
ASME CSD1 : 2012 | CONTROLS AND SAFETY DEVICES FOR AUTOMATICALLY FIRED BOILERS |
WW-F-2743 Revision A:1998 | FURNACES, WARM AIR & HEATERS, UNIT, FORCED AIR CIRCULATION, OIL & GAS FIRED |
ICC 2012 INTERNATIONAL RESI. CODE : 2012 | INTERNATIONAL RESIDENTIAL CODE FOR ONE- AND TWO-FAMILY DWELLINGS |
UL 2106:2ED 2006-04-18 | Standard for Field Erected Boiler Assemblies |
ICC IRC CODE AND COMMENTARY VOLUME 2 : 2015 | IRC® Code and Commentary, Volume 2 |
NFPA 31 : 2016 | INSTALLATION OF OIL-BURNING EQUIPMENT |
ANSI/CSA FC 1:2014 | FUEL CELL TECHNOLOGIES - PART 3-100: STATIONARY FUEL CELL POWER SYSTEMS - SAFETY |
NFPA 87 : 2018 | FLUID HEATERS |
ICC 2012 INTERNATIONAL FUEL GAS CODE : 2012 | INTERNATIONAL FUEL GAS CODE |
CSA C22.2 No. 168 : 2016 | COMMERCIAL DISHWASHERS |
ASHRAE HDBK REFRIGERATION : 2014 | ASHRAE HANDBOOK - REFRIGERATION |
ANSI Z83.21 : 2016 | COMMERCIAL DISHWASHERS |
CSA FC 3 : 2004 | PORTABLE FUEL CELL POWER SYSTEMS |
ANSI/CSA AMERICA FC 3-2004 (R2017) | PORTABLE FUEL CELL POWER SYSTEMS |
UL 514A:11ED 2013-02-01 | Metallic Outlet Boxes |
UL 5085-3:1ED 2006-04-17 | Low Voltage Transformers - Part 3: Class 2 and Class 3 Transformers |
UL 506:14ED 2017-06-02 | Specialty Transformers |
UL 83:16ED 2017-07-28 | Standard for Thermoplastic-Insulated Wires and Cables |
UL 4248-9:1ED 2007-02-28 | Fuseholders - Part 9: Class K |
UL 60730-2-9:4ED 2017-02-14 | Automatic Electrical Controls - Part 2-9: Particular Requirements for Temperature Sensing Controls |
UL 296:11ED 2017-02-24 | Oil Burners |
UL 514C:4ED 2014-04-08 | Nonmetallic Outlet Boxes, Flush-Device Boxes, and Covers |
UL 60730-1:5ED 2016-08-03 | Automatic Electrical Controls - Part 1: General Requirements |
UL 2250:3ED 2017-03-30 | Instrumentation Tray Cable |
UL 248-5:2ED 2000-08-01 | Low-Voltage Fuses - Part 5: Class G Fuses |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.