Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
    3.1 Definitions
    3.2 Abbreviations
4 General considerations
5 Operational requirement
    5.1 Purpose of the operational requirement
    5.2 Contents of the operational requirement
6 System operational criteria
    6.1 Determining operational procedures
    6.2 Alarm response
    6.3 System trigger response times
7 System design criteria
    7.1 Surveillance zone determination criteria
    7.2 Criteria for determining the number of cameras
          and their location
    7.3 Camera and lens selection criteria
    7.4 Camera selection
    7.5 Lens selection
    7.6 Recommended object sizes
    7.7 Ancillary equipment
    7.8 Evaluation of scene and illumination
    7.9 Selection of the video transmission system
    7.10 Control centre configuration
    7.11 System specification
    7.12 System test specification
8 Installation
    8.1 Planning the installation
    8.2 Cable installation
    8.3 Hardware mounting
    8.4 Documentation
9 Commissioning and hand-over
10 Maintenance
    10.1 Modifications
Annex A (informative)
    A.1 The Rotakin test target method
    A.2 Specification of the Rotakin test target
    A.3 Bibliography
Annex B (informative)
    Glossary of terms

Gives recommendations for selection, planning and installation of closed television systems including camera(s) with monitor(s) and/or video recorder(s), switching, control and ancillary equipment to be used in security applications. It provides a framework for assistance of customers, installers and users in establishing requirements, assists specifiers and users in determining correct equipment for a given application and gives means of evaluating objectively the performance of an installed system.

DocumentType
Standard
PublisherName
Swiss Standards
Status
Superseded
SupersededBy

Standards Relationship
NBN EN 50132-7 : 2012 Identical
NEN EN 50132-7 : 2012 Identical
BS EN 50132-7:2012 Identical
EN 50132-7:2012 Identical
DIN EN 50132-7 : 2013 Identical
I.S. EN 50132-7:2012 Identical
UNE-EN 50132-7:2013 Identical
NF EN 50132-7 : 2012 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more