SAE AS 4373 : 2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
TEST METHODS FOR INSULATED ELECTRIC WIRE
Hardcopy , PDF
12-03-2020
English
01-01-2012
Describes test methods for insulated, single conductor, electric wire intended for aerospace applications.
Committee |
AE-8D
|
DocumentType |
Revision
|
Pages |
103
|
PublisherName |
SAE International
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
SAE AS 4372 : 2014 | PERFORMANCE REQUIREMENTS FOR WIRE, ELECTRIC, INSULATED COPPER OR COPPER ALLOY |
DSCC 04046 : D | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, LIGHT WEIGHT, NICKEL COATED, COPPER CONDUCTOR, 260 DEGREES C, 600 VOLT |
DSCC 04048 : C | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, 26, 20, 18, 16 AWG, 600 VOLT |
DSCC 04039 : D | WIRE, ELECTRICAL, COMPOSITE, POLYAMIDE BRAID, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, TIN COATED, COPPER CONDUCTOR, 150 DEGREES C, 600 VOLT |
DSCC 04040 : C | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, SILVER COATED, COPPER CONDUCTOR, 200 DEGREES C, 600 VOLT |
SAE AIR 5558 : 2015 | ULTRAVIOLET (UV) LASER MARKING PERFORMANCE OF AEROSPACE WIRE CONSTRUCTIONS |
SAE ARP 4404 : 2013 : R2019 | AIRCRAFT ELECTRICAL INSTALLATIONS |
FAA AC 25.1701-1 : 2007 | CERTIFICATION OF ELECTRICAL WIRING INTERCONNECTION SYSTEMS ON TRANSPORT CATEGORY AIRPLANES |
SAE AS 5419 : 2003 | CABLE, THERMOCOUPLE EXTENSION, SHIELDED AND UNSHIELDED |
SAE ARP 6216 : 2017 | EWIS WIRING INSULATION BREAKDOWN TESTING |
SAE AS 5942 : 2014 | MARKING OF ELECTRICAL INSULATING MATERIALS |
DSCC 04036 : D | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, LIGHT WEIGHT, NICKEL COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH COPPER ALLOY, 260 DEGREES C, 600 VOLT |
SAE ARP 5369 : 2016 | GUIDELINES FOR WIRE IDENTIFICATION MARKING USING THE HOT STAMP PROCESS |
SAE ARP 5614 : 2014 | GUIDELINES FOR HARNESS CRITICAL CLAMP LOCATOR MARKER INSTALLATION ON ELECTRICAL CABLE ASSEMBLIES |
DSCC 04038 : D | WIRE, ELECTRICAL, COMPOSITE, POLYAMIDE BRAID, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, NICKEL COATED, COPPER CONDUCTOR, 260 DEGREES C, 600 VOLT |
DSCC 04037 : C | WIRE, ELECTRICAL, COMPOSITE, POLYAMIDE BRAID, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, SILVER COATED, COPPER CONDUCTOR, 200 DEGREES C, 600 VOLT |
DSCC 04042 : D | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, TIN COATED, COPPER CONDUCTOR, 150 DEGREES C, 600 VOLT |
DSCC 04041 : D | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, NICKEL COATED, COPPER CONDUCTOR, 260 DEGREES C, 600 VOLT |
SAE ARP 4404 : 2013 | AIRCRAFT ELECTRICAL INSTALLATIONS |
SAE AIR 4004 : 2015 | GUIDE FOR INSTALLATION OF ELECTRICAL WIRE AND CABLE ON AIRCRAFT LANDING GEAR |
DSCC 04045 : D | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, LIGHT WEIGHT, SILVER COATED, COPPER CONDUCTOR, 200 DEGREES C, 600 VOLT |
SAE ARP 6229 : 2012 | FLUORIDE OFFGASSING IN FLUOROPOLYMER INSULATIONS |
NASA STD 6001(INT) : 2009 | FLAMMABILITY, OFFGASSING, AND COMPATIBILITY REQUIREMENTS AND TEST PROCEDURES |
NASA STD 6001 : 2011 | FLAMMABILITY, OFFGASSING, AND COMPATIBILITY REQUIREMENTS AND TEST PROCEDURES |
DSCC 04034 : C | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, LIGHT WEIGHT, COPPER CONDUCTOR, TIN COATED, 150 DEGREES C, 600 VOLT |
SAE AS 5649 : 2012 | WIRE AND CABLE MARKING PROCESS, UV LASER |
SAE AS 60491 : 2015 | SLEEVE, PROTECTION, FOR CABLE AND HARNESS PROTECTION |
DSCC 04047 : D | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, 30, 28, 26 AWG, 600 VOLT |
DSCC 04043 : D | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, SILVER COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH COPPER ALLOY, 200 DEGREES C, 600 VOLT |
SAE ARP 5607 : 2013 | LEGIBILITY OF PRINT ON AEROSPACE WIRES AND CABLES |
DSCC 04035 : A13032009 | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, LIGHT WEIGHT, SILVER COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH COPPER ALLOY, 200 DEGREES C, 600 VOLT |
SAE AS 50881 : 2015 | WIRING AEROSPACE VEHICLE |
SAE AS 6019 : 2012 | ARC FAULT CIRCUIT BREAKER (AFCB), AIRCRAFT, TRIP-FREE 28 VDC |
DSCC 04044 : D | WIRE, ELECTRICAL, COMPOSITE, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH WEIGHT, NORMAL WEIGHT, NICKEL COATED, HIGH STRENGTH OR ULTRA HIGH STRENGTH COPPER ALLOY, 260 DEGREES C, 600 VOLT |
MIL-STD-2223 Base Document:1992 | TEST METHODS FOR INSULATED ELECTRIC WIRE |
SAE AS 6070 : 2015 | AEROSPACE CABLE, HIGH SPEED DATA, COPPER |
DSCC 04037 D : 2019 | WIRE, ELECTRICAL, COMPOSITE, POLYAMIDE BRAID, POLYTETRAFLUOROETHYLENE/POLYIMIDE INSULATED, SMOOTH SURFACE, NORMAL WEIGHT, SILVER COATED, COPPER CONDUCTOR, 200 DEGREES C, 600 VOLT |
SAE AS 22759 : 2014 | WIRE, ELECTRICAL, FLUOROPOLYMER-INSULATED, COPPER OR COPPER ALLOY |
SAE AS 6324 : 2017 | VERIFICATION OF NEW CONDUCTOR ALLOYS FOR AS29606 CONDUCTORS QUALIFICATION |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.