S.R. HD 60364-5-557:2013
Current
The latest, up-to-date edition.
LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-557: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - AUXILIARY CIRCUITS
Hardcopy , PDF
English
01-01-2016
National Foreword
FOREWORD
557 Auxiliary circuits
557.1 Scope
557.2 Terms and definitions
557.3 Requirements for auxiliary circuits
557.4 Characteristics of cables and
conductors - Minimum cross-sectional areas
557.5 Requirements for auxiliary circuits used for measurement
557.6 Functional consideration
557.7 Functional safety
557.8 EMC
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Pertains to auxiliary circuits, except those covered by specific product or system standards.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (02/2018)
|
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
HD 60364-5-557:2013/A11:2016 | Identical |
IEC 60038:2009 | IEC standard voltages |
IEC 60364-4-43:2008 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 60364-7-712:2017 | Low voltage electrical installations - Part 7-712: Requirements for special installations or locations - Solar photovoltaic (PV) power supply systems |
HD 60364-4-43:2010 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 60364-7-717:2009 | Low-voltage electrical installations - Part 7-717: Requirements for special installations or locations - Mobile or transportable units |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
HD 60364-4-42 : 2011 AMD 1 2015 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014) |
EN 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
HD 60364-1:2008/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 1: FUNDAMENTAL PRINCIPLES, ASSESSMENT OF GENERAL CHARACTERISTICS, DEFINITIONS |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
HD 60364-7-712:2016 | Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems |
IEC 61557-9:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems |
IEC 61439-1:2011 | Low-voltage switchgear and controlgear assemblies - Part 1: General rules |
EN 61557-8:2015/AC:2016-06 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 60364-4-42:2010+AMD1:2014 CSV | Low-voltage electrical installations - Part 4-42: Protection forsafety - Protection against thermal effects |
HD 60364-7-717:2010/AC:2014 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-717: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MOBILE OR TRANSPORTABLE UNITS |
EN 61557-9:2015/AC:2017-02 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017) |
EN 60038:2011 | CENELEC STANDARD VOLTAGES (IEC 60038:2009, MODIFIED) |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.