S.R. CWA 15897:2008
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
SUBMERGED MEMBRANE BIOREACTOR (MBR) TECHNOLOGY
Hardcopy , PDF
13-05-2021
English
01-01-2008
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General system - requirements
4.1 Basic considerations
4.2 Pre-treatment and internal sieving
4.3 Characteristics of biological systems used in MBR plants
4.3.1 General
4.3.2 Mixed liquor suspended solids (MLSS)
4.3.3 Hydraulic retention time (HRT (or detention time))
4.3.4 Sludge age (or sludge retention time (SRT))
4.3.5 Chemical phosphorus removal
4.3.6 Aeration
4.4 Membrane filtration system
4.5 Mixed liquor recirculation
4.6 Permeate extraction system
4.7 Desired effluent quality
5 Material characteristics
5.1 General
5.2 Porous membranes
6 Configuration
6.1 Flat Sheet
6.2 Hollow fibre
7 Design and operating parameters
7.1 General
7.2 Influent characteristics
7.3 Fouling
7.4 Transmembrane pressure
7.5 Permeability
7.6 Integrity
8 Acceptance, commissioning and monitoring tests
9 Information and Documentation
10 Interchangeability
10.1 Principle
10.2 General
10.3 Process flow diagram (PFD)
10.4 Scope of supply
10.5 Interchangeability aspects
10.5.1 General
10.5.2 Membrane type
10.5.3 Layout
10.5.4 Tank
10.5.5 Draining and flushing
10.5.6 Integrity check
10.5.7 Accessibility and maintainability
10.5.8 Chemical cleaning
10.5.9 Process control system (PLC)
Annex A (normative) Information and documentation
Annex B (informative) Example for clean water permeability test
B.1 Abstract
B.2 Materials and methods
B.2.1 Measuring apparatus
B.2.2 Measuring procedure
Annex C (informative) Example for vacuum leak test
C.1 Abstract
C.2 Materials and methods
C.2.1 Measuring apparatus
C.2.2 Measuring procedure
Annex D (informative) Example for pore diameter measurement
D.1 Abstract
D.2 Materials and methods
D.2.1 Latex solution
D.2.2 Measuring apparatus
D.2.3 Measuring procedure
Annex E (informative) Paper filtration measurement
E.1 Objective
E.2 Measuring method
Annex F (informative) Impact of pore size distribution on
membrane fouling
Bibliography
Describes terms commonly used in the field of membrane bioreactor technology.
DocumentType |
Standard
|
Pages |
51
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
SupersededBy |
EN 12255-10:2000 | Wastewater treatment plants - Part 10: Safety principles |
EN 872:2005 | Water quality - Determination of suspended solids - Method by filtration through glass fibre filters |
EN 12255-6:2002 | Wastewater treatment plants - Part 6: Activated sludge process |
EN 12255-13:2002 | Wastewater treatment plants - Part 13: Chemical treatment - Treatment of wastewater by precipitation/flocculation |
EN 12255-11:2001 | Wastewater treatment plants - Part 11: General data required |
DIN 58355-2:2005-01 | MEMBRANE FILTERS - PART 2: TESTING FOR BUBBLE POINT |
EN 12255-1:2002 | Wastewater treatment plants - Part 1: General construction principles |
EN 1085:2007 | Wastewater treatment - Vocabulary |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.