Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

S.R. CLC/TS 50131-2-8:2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-8: INTRUSION DETECTORS - SHOCK DETECTORS

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2012

Superseded date

23-01-2017

Superseded by

I.S. EN 50131-2-8:2016

$129.17
Including GST where applicable

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (normative) - Standard test material
Annex B (normative) - Dimensions and requirements of the
        standardised Test Magnets
Annex C (normative) - General Testing Matrix
Annex D (normative) - Standard immunity glass pane
Annex E (normative) - Spring operated Hammer
Annex F (informative) - Example list of small tools
Annex G (normative) - Minimum performance requirements
        gross and shock integration attack tests
Annex H (normative) - Immunity test: Small objects hit
        sensitivity
Annex I (normative) - Immunity test: Hard objects hit
        sensitivity
Annex J (normative) - Immunity test: Static pressure
        sensitivity
Annex K (normative) - Immunity test: Dynamic pressure
        sensitivity
Bibliography

Applies to shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows).

DocumentType
Standard
Pages
52
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

Standards Relationship
CLC/TS 50131-2-8:2012 Identical

EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60068-2-52:2017 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
EN 50130-5:2011 Alarm systems - Part 5: Environmental test methods

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

$129.17
Including GST where applicable