PREN 50443 : DRAFT 2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
EFFECTS OF ELECTROMAGNETIC INTERFERENCE ON PIPELINES CAUSED BY HIGH VOLTAGE A.C. ELECTRIC TRACTION SYSTEMS AND/OR HIGH VOLTAGE A.C. POWER SUPPLY SYSTEMS
01-12-2011
12-01-2013
1 Scope
2 Normative references
3 Terms and definitions
4 Procedure
5 Interference distance
6 Interference situations
7 Coupling types
8 Interference
9 Interference results
10 Limits for permissible interference
11 Evaluation of the interference results
12 Mitigation measures
Annex A (informative) - Indications to select
interference situations
Annex B (informative) - Guidance for interference
investigations
Annex C (informative) - Measuring methods
Annex D (informative) - Mitigation measures
Annex E (informative) - Management of interference
Bibliography
Describes: - the procedure for evaluating the e.m. interference; - the interference distance to be considered; - the types of coupling to be considered for operating and fault conditions of the high voltage a.c. electric traction systems and high voltage a.c. power supply systems; - the configurations to be considered for both metallic pipeline and high voltage a.c. electric traction systems or high voltage a.c. power systems; - the limits of the voltages due to the electromagnetic interference; and - information on interference situations, calculation methods, measuring methods, mitigation measures, management of interference.
Committee |
SC 9XC
|
DocumentType |
Draft
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 50443 : 2012 | Identical |
NEN EN 50443 : 2011 | Identical |
VDE 0845-8 : 2012 | Identical |
11/30246420 DC : 0 | Identical |
DIN EN 50443 : 2012 | Identical |
04/30125295 DC : 0 | Identical |
CEN/TS 15280:2006 | Evaluation of a.c. corrosion likelihood of buried pipelines - Application to cathodically protected pipelines |
DD CEN/TS 15280:2006 | Evaluation of a.c. corrosion likelihood of buried pipelines. Application to cathodically protected pipelines |
I.S. CEN TS 15280:2006 | EVALUATION OF A.C. CORROSION LIKELIHOOD OF BURIED PIPELINES - APPLICATION TO CATHODICALLY PROTECTED PIPELINES |
EN 50122-1:2011/A4:2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
EN 14505:2005 | Cathodic protection of complex structures |
HD 384.6.61 : 200S2 | ELECTRICAL INSTALLATIONS OF BUILDINGS - VERIFICATION - INITIAL VERIFICATION |
EN 50110-1:2013 | Operation of electrical installations - Part 1: General requirements |
IEC 60364-6-61:2001 | Electrical installations of buildings - Part 6-61: Verification - Initial verification |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.