Customer Support: 131 242

  • Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

PREN 14491 : DRAFT 2011

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

DUST EXPLOSION VENTING PROTECTIVE SYSTEMS

Superseded date

01-08-2012

Superseded by

EN 14491:2012

Published date

12-01-2013

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Venting of enclosures
5 Sizing of vent areas
6 Supplementary design considerations
7 Marking
8 Information for use
Annex A (informative) - Influence of the filter elements
        on the explosion venting
Annex B (informative) - Explosion venting of cyclones
Annex C (informative) - Estimating the L/D ratio when
        calculating vent areas for elongated enclosures
Annex D (informative) - Protection of buildings
Annex E (informative) - Significant changes between
        this European Standard and EN 14491:2006
Annex ZA (informative) - Relationship between this
         European Standard and the Essential
         Requirements of EU Directive 94/9/EC
Bibliography

Describes the basic requirements of design for the selection of a dust explosion venting protective system.

Committee
TC 305
DocumentType
Draft
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
11/30247683 DC : 0 Identical
09/30190323 DC : 0 Identical
02/540556 DC : DRAFT JULY 2002 Identical

05/30134150 DC : DRAFT MAY 2005 EN 15233 - METHODOLOGY FOR FUNCTIONAL SAFETY ASSESSMENT OF PROTECTIVE SYSTEMS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES
BS EN 14373:2005 Explosion suppression systems
EN 14373:2005 Explosion suppression systems
04/30117071 DC : DRAFT JUL 2004 EN 14994 - GAS EXPLOSION VENTING PROTECTIVE SYSTEMS
VDI 2263 Blatt 7:2010-07 Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in spraying and drying integrated equipment
VDI 2263 Blatt 8.1:2011-03 Dust fires and dust explosions - Hazards - assessment - protective measures - Fire and explosion protection on elevators - Examples
11/30247811 DC : 0 BS EN 415-10 - SAFETY OF PACKAGING MACHINES - PART 10: GENERAL REQUIREMENTS
04/30125922 DC : 0 EN 15089 - EXPLOSION ISOLATION SYSTEMS
DIN EN 14373:2006-01 Explosion suppression systems
I.S. EN 14373:2005 EXPLOSION SUPPRESSION SYSTEMS

EN 1127-1:2011 Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology
EN 15089:2009 Explosion isolation systems
EN 14034-2:2006+A1:2011 Determination of explosion characteristics of dust clouds - Part 2: Determination of the maximum rate of explosion pressure rise (dp/dt)max of dust clouds
EN 14797:2006 Explosion venting devices
EN 13237:2012 Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres
PREN 16009 : DRAFT 2009 FLAMELESS EXPLOSION VENTING DEVICES
EN 14034-1:2004+A1:2011 Determination of explosion characteristics of dust clouds - Part 1: Determination of the maximum explosion pressure pmax of dust clouds

Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.