GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - PRODUCT STANDARD
12-01-2013
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Assessment and verification of constancy of
performance - AVCP
6 Marking and/or labeling
Annex A (informative) - Factory production control
Annex B (informative) - Tests for ensuring conformity
Annex C (informative) - Laminated safety glass - mechanical
resistance tests
Annex D (normative) - Safety in use - Mechanical resistance -
Resistance against wind, snow, permanent load and/or
imposed loads of the glass unit
Annex E (informative) - Provisions for voluntary involvement
of third party(ies)
Annex ZA (informative) - Relationship of this European
Standard with Regulation (EU) No 305/2011
Bibliography
Provides the assessment and verification of constancy of performances and the factory production control of laminated glass and laminated safety glass for use in buildings.
Committee |
TC 129
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
17/30365059 DC | Identical |
NEN EN 14449 : 2005 C1 2006 | Identical |
02/103123 DC : DRAFT APR 2002 | Identical |
BS 6510:2005 | Steel-framed windows and glazed doors |
05/30134012 DC : 0 | EN 15254-4 - EXTENDED APPLICATION OF RESULTS FROM FIRE RESISTANCE TESTS - NON-LOADBEARING WALLS - PART 4: GLAZED CONSTRUCTION |
04/30123426 DC : DRAFT OCT 2004 | BS 6262-4 - GLAZING FOR BUILDINGS - PART 4: SAFETY RELATED TO HUMAN IMPACT - CODE OF PRACTICE |
04/30100932 DC : DRAFT AUG 2004 | BS 6510 - STEEL-FRAMED WINDOWS AND GLAZED DOORS |
EN 14321-2:2005 | Glass in building - Thermally toughened alkaline earth silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 572-3:2012 | Glass in building - Basic soda lime silicate glass products - Part 3: Polished wired glass |
EN 12337-1:2000 | Glass in building - Chemically strengthened soda lime silicate glass - Part 1: Definition and description |
EN 13024-1:2011 | Glass in building - Thermally toughened borosilicate safety glass - Part 1: Definition and description |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
EN 1748-2-1:2004 | Glass in building - Special basic products - Glass ceramics - Part 2-1 Definitions and general physical and mechanical properties |
EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
EN 14321-1:2005 | Glass in building - Thermally toughened alkaline earth silicate safety glass - Part 1: Definition and description |
EN 14179-1:2016 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN 15681-1:2016 | Glass in building - Basic alumino silicate glass products - Part 1: Definitions and general physical and mechanical properties |
EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
EN 12898:2001 | Glass in building - Determination of the emissivity |
305/2011 : 2011 AMD 2 2014 | REGULATION (EU) NO 305/2011 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 2011 LAYING DOWN HARMONISED CONDITIONS FOR THE MARKETING OF CONSTRUCTION PRODUCTS AND REPEALING COUNCIL DIRECTIVE 89/106/EEC (TEXT WITH EEA RELEVANCE) |
EN ISO 12543-2:2011 | Glass in building - Laminated glass and laminated safety glass - Part 2: Laminated safety glass (ISO 12543-2:2011) |
ISO 12543-3:2011 | Glass in building Laminated glass and laminated safety glass Part 3: Laminated glass |
EN 1863-1:2011 | Glass in building - Heat strengthened soda lime silicate glass - Part 1: Definition and description |
EN 13501-5:2016 | Fire classification of construction products and building elements - Part 5: Classification using data from external fire exposure to roofs tests |
EN 14178-1:2004 | Glass in building - Basic alkaline earth silicate glass products - Part 1: Float glass |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
EN ISO 12543-3:2011 | Glass in building - Laminated glass and laminated safety glass - Part 3: Laminated glass (ISO 12543-3:2011) |
EN 16477-1:2016 | Glass in building - Painted glass for internal use - Part 1: Requirements |
EN 1036-1:2007 | Glass in building - Mirrors from silver-coated float glass for internal use - Part 1: Definitions, requirements and test methods |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 14179-2:2005 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
ISO 12543-2:2011 | Glass in building Laminated glass and laminated safety glass Part 2: Laminated safety glass |
PREN 16612 : DRAFT 2017 | GLASS IN BUILDING - DETERMINATION OF THE LATERAL LOAD RESISTANCE OF GLASS PANES BY CALCULATION |
EN 572-6:2012 | Glass in building - Basic soda lime silicate glass products - Part 6: Wired patterned glass |
PREN 16613 : DRAFT 2013 | GLASS IN BUILDING - LAMINATED GLASS AND LAMINATED SAFETY GLASS - DETERMINATION OF INTERLAYER MECHANICAL PROPERTIES |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
EN 12150-1:2015 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN 1863-2:2004 | Glass in building - Heat strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 1063:1999 | Glass in building - Security glazing - Testing and classification of resistance against bullet attack |
EN 1748-1-1:2004 | Glass in building - Special basic products -Borosilicate glasses - Part 1-1: Definition and general physical and mechanical properties |
EN 12150-2:2004 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN 572-4:2012 | Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass |
ISO 12543-1:2011 | Glass in building Laminated glass and laminated safety glass Part 1: Definitions and description of component parts |
ISO 9001:2015 | Quality management systems — Requirements |
EN 572-1:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties |
ISO 12543-4:2011 | Glass in building Laminated glass and laminated safety glass Part 4: Test methods for durability |
EN ISO 12543-4:2011 | Glass in building - Laminated glass and laminated safety glass - Part 4: Test methods for durability (ISO 12543-4:2011) |
ISO 12543-6:2011 | Glass in building Laminated glass and laminated safety glass Part 6: Appearance |
EN 572-5:2012 | Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass |
EN 572-8:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 8: Supplied and final cut sizes |
EN 13024-2:2004 | Glass in building - Thermally toughened borosilicate safety glass - Part 2: Evaluation of conformity/Product standard |
EN ISO 12543-5:2011 | Glass in building - Laminated glass and laminated safety glass - Part 5: Dimensions and edge finishing (ISO 12543-5:2011) |
ISO 9385:1990 | Glass and glass-ceramics Knoop hardness test |
EN 15998:2010 | Glass in building - Safety in case of fire, fire resistance - Glass testing methodology for the purpose of classification |
EN 15682-1:2013 | Glass in building - Heat soaked thermally toughened alkaline earth silicate safety glass - Part 1: Definition and description |
ISO 12543-5:2011 | Glass in building Laminated glass and laminated safety glass Part 5: Dimensions and edge finishing |
EN ISO 12543-1:2011 | Glass in building - Laminated glass and laminated safety glass - Part 1: Definitions and description of component parts (ISO 12543-1:2011) |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |