PREN 13205 : DRAFT 2010
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
WORKPLACE EXPOSURE - ASSESSMENT OF SAMPLER PERFORMANCE FOR MEASUREMENT OF AIRBORNE PARTICLE CONCENTRATIONS
01-10-2012
PREN 13205-1 : DRAFT 2012
PREN 13205-2 : DRAFT 2012
PREN 13205-4 : DRAFT 2012
PREN 13205-5 : DRAFT 2012
PREN 13205-6 : DRAFT 2012
12-01-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Requirements
6 Test methods
7 Types of evaluation
8 Instructions for use
9 Marking, quality control
Annex A (normative) - Laboratory performance test,
based on determination of sampling efficiency
and modelling of concentrations determined by
sampling
Annex B (normative) - Laboratory performance test,
based on comparison of concentrations determined
with the candidate sampler and a validated sampler
Annex C (normative) - Workplace performance test,
based on comparison of concentrations determined
with the candidate sampler and a validated sampler
Annex D (informative) - Recommended procedure
for a workplace comparison of a candidate sampler
and a validated sampler in order to obtain a
correction factor
Annex E (normative) - Transport test based on
weighing samples before and after shipping
by mail
Annex F (normative) - Handling test for loaded
samplers or collection substrates using
a shaker
Annex G (normative) - Calculation of expanded
uncertainty for a measurement procedure
Annex H (informative) - Analysis of sampling
efficiency data from a performance test according
to Annex A
Bibliography
Describes methods for testing aerosol samplers under prescribed laboratory conditions, and performance requirements that are specific to aerosol samplers. These performance requirements, which include conformity with the EN 481 sampling conventions, apply only to the process of sampling the airborne particles from the air, not to the process of analyzing particles collected by the process of sampling. Although analysis of samples collected in the course of testing is usually necessary in order to evaluate the sampler performance, the specified test methods ensure that analytical errors are kept very low during testing and do not contribute significantly to the end result. The determination of analytical errors and factors related to them (for example the bias, precision and limit of detection of the analytical method) is outside the scope of this standard. Where the aerosol sampler requires the use of an external (rather than integral) pump, the pump is not subject to the requirements of this standard.
Committee |
TC 137
|
DevelopmentNote |
Superseded by PREN 13205-1, PREN 13205-2, PREN 13205-4, PREN 13205-5 and PREN 13205-6 but remains current. (10/2012)
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
11/30228336 DC : 0 | Identical |
13/30231417 DC : 0 | BS ISO 16258-2 - WORKPLACE AIR - RESPIRABLE CRYSTALLINE SILICA BY X-RAY DIFFRACTION - PART 2: METHOD BY INDIRECT ANALYSIS |
DD ENV 13936:2001 | Workplace atmospheres. Measurement of chemical agents present as mixtures of airborne particles and vapour. Requirements and test methods |
ASTM D 6552 : 2006 : R2016 | Standard Practice for Controlling and Characterizing Errors in Weighing Collected Aerosols |
ASTM D 6552 : 2006 : R2011 | Standard Practice for Controlling and Characterizing Errors in Weighing Collected Aerosols |
ENV 13936 : DRAFT 2001 | WORKPLACE ATMOSPHERES - MEASUREMENT OF CHEMICAL AGENTS PRESENT AS MIXTURES OF AIRBORNE PARTICLES AND VAPOUR - REQUIREMENTS AND TEST METHODS |
ASTM D 6552 : 2006 | Standard Practice for Controlling and Characterizing Errors in Weighing Collected Aerosols |
EN 14530:2004 | Workplace atmospheres - Determination of diesel particulate matter - General requirements |
EN 12919:1999 | Workplace atmospheres - Pumps for the sampling of chemical agents with a volume flow rate of over 5 l/min - Requirements and test methods |
ISO 24095:2009 | Workplace air Guidance for the measurement of respirable crystalline silica |
EN 481:1993 | Workplace atmospheres - Size fraction definitions for measurement of airborne particles |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
EN 13890:2009 | Workplace exposure - Procedures for measuring metals and metalloids in airborne particles - Requirements and test methods |
ISO 21438-3:2010 | Workplace atmospheres — Determination of inorganic acids by ion chromatography — Part 3: Hydrofluoric acid and particulate fluorides |
ISO 3534-2:2006 | Statistics — Vocabulary and symbols — Part 2: Applied statistics |
ISO 21438-1:2007 | Workplace atmospheres Determination of inorganic acids by ion chromatography Part 1: Non-volatile acids (sulfuric acid and phosphoric acid) |
EN 1232:1997 | Workplace atmospheres - Pumps for personal sampling of chemical agents - Requirements and test methods |
ISO 15767:2009 | Workplace atmospheres Controlling and characterizing uncertainty in weighing collected aerosols |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.