European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 General
5 Standard performances
6 Constraints
7 Functional aspects
8 System simulation and equipment sizing
Bibliography

Gives recommendations for DC reversible substations.

Committee
GEL/9/3
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Current

This Technical Report provides recommendations for DC reversible substations. These recommendations apply to systems and components that facilitate the flow of energy to and from the upstream AC grid including their related interfaces.

These recommendations provide the necessary functions for the recovery of braking energy. It is intended to be used in fixed electrical installations with nominal voltage not exceeding 3000V DC which supply electrical power to vehicles used in public guided transport systems, i.e. railway vehicles, tramway vehicles, underground vehicles and trolley-buses

It is intended to provide an overview of state-of-the-art applications, define the minimum recommendations that are presently available, and provide functional recommendations to be applied to these substations.

This document focuses mainly on the substation converters and the traction transformers. Other devices such as switchgear - if they are the same as in classic substations - are not addressed here. Moreover this specification addresses performance, constraints, validation and acceptance criteria for the implementation of reversible substations.

This document provides the minimum recommendations to be fulfilled. However, due to the different possible solutions and different types of existing technologies, this document does not provide technical specifications of the basic components that facilitate the functionalities described.

Standards Relationship
CLC/TR 50646:2015 Identical

CLC/TS 50591:2013 Specification and verification of energy consumption for railway rolling stock
EN 50160 : 2010 AMD 1 2015 VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS
EN 50124-2:2017 Railway applications - Insulation coordination - Part 2: Overvoltages and related protection
IEC 60146-1-3:1991 Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors
IEC 61000-2-4:2002 Electromagnetic compatibility (EMC) - Part 2-4: Environment - Compatibility levels in industrial plants for low-frequency conducted disturbances
EN 60146-1-1:2010 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
IEC 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
EN 50122-1:2011/A4:2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK
EN 61000-2-12:2003 Electromagnetic compatibility (EMC) - Part 2-12: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public medium-voltage power supply systems
EN 50123-2:2003 Railway applications - Fixed installations - D.C. switchgear - Part 2: D.C. circuit breakers
EN 50123-1:2003 Railway applications - Fixed installations - D.C. switchgear - Part 1: General
EN 50121-1:2017 Railway applications - Electromagnetic compatibility - Part 1: General
EN 61000-2-4:2002/AC:2014 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 2-4: ENVIRONMENT - COMPATIBILITY LEVELS IN INDUSTRIAL PLANTS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES
EN 50122-2:2010 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 2: PROVISIONS AGAINST THE EFFECTS OF STRAY CURRENTS CAUSED BY D.C. TRACTION SYSTEMS
EN 60146-1-3:1993 Semiconductor convertors - General requirements and line commutated convertors - Part 1-3: Transformers and reactors
EN 50124-1:2017 Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment
EN 50329:2003/A1:2010 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS
EN 50125-2:2002/corrigendum:2010 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS
EN 61800-5-1:2007/A1:2017 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 5-1: SAFETY REQUIREMENTS - ELECTRICAL, THERMAL AND ENERGY (IEC 61800-5-1:2007/A1:2016)
IEC 60146-1-1:2009 Semiconductor converters - General requirements and line commutated converters - Part 1-1: Specification of basic requirements
EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
IEC TR 60146-1-2:2011 Semiconductor converters - General requirements and line commutated converters - Part 1-2: Application guide
IEC 61643-11:2011 Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
EN 50163 : 2004 COR 2013 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
EN 50121-2:2017 Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world
EN 50121-5:2017 Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus
EN 50388 : 2012 COR 2013 RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY
CLC/TS 50562:2011 Railway applications - Fixed installations - Process, measures and demonstration of safety for electric traction systems
IEC TR 61000-3-6:2008 Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems
EN 50328 : 2003 COR 2006 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRONIC POWER CONVERTERS FOR SUBSTATIONS