PD CLC/TR 50126-3:2008
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Railway applications. The specification and demonstration of reliability, availability, maintainability and safety (RAMS) Guide to the application of EN 50126-1 for rolling stock RAM
Hardcopy , PDF
10-05-2024
English
30-09-2008
Introduction
1 Scope
2 Definitions
3 Approach adopted for the Guide
3.1 General
3.2 Entities Involved In the Life Cycle Phases of Rolling Stock
4 Application of this Guide
4.1 Object of the application
4.2 Application of EN 50126-1
4.2.1 Assessment of the application of EN 50126-1
4.2.2 Mandatory requirements for the application of EN 50126-1
5 Specifying RAM requirements
5.1 Introduction
5.2 Preliminary RAM analysis
5.2.1 General
5.2.2 Preliminary RAM Analysis activities
5.2.2.1 General
5.2.2.2 System Identification
5.2.2.3 Breakdown structure and boundary limits
5.2.2.4 Failure Conditions
5.3 RAM requirements
5.3.1 Introduction
5.3.2 Reliability Targets
5.3.3 Maintainability Targets
5.3.3.1 Generic Qualitative Requirements for
Maintainability
5.3.3.2 Preventive/Corrective Maintenance Requirements
5.3.3.3 Logistic Support Requirements
5.3.3.4 Maintenance Cost Requirements
5.3.4 Availability Targets
5.4 Process for choosing RAM figures
5.5 RAM Programme
5.5.1 Introduction
5.5.2 Configuration Management System
5.5.3 RAM Programme Outline
5.5.4 Example of RAM Analyses Document Template and Data
5.5.4.1 Introduction
5.5.4.2 Common Data for the analyses
5.5.4.3 Reliability Prediction Analysis Template and
Data Sheets
5.5.4.4 Maintenance Attributes (Maintenance Levels,
Skill Level and LRU definition)
5.5.4.5 Preventive Maintenance Analysis Template and
Data Sheets
5.5.4.6 Corrective Maintenance Analysis Template and
Data Sheets
5.5.4.7 Failure Mode Effects and Criticality Analysis
Template and Data Sheets
6 RAM Assurance during Life Cycle
6.1 RAM Programme and Phases of the Life Cycle
6.1.1 Introduction
6.1.2 Tender Phase
6.1.3 Design Phase
6.1.4 Demonstration Phase
6.1.4.1 Introduction
6.1.4.2 RAM Acceptance Criteria
6.1.4.3 In service checking Period
6.1.4.4 Data Report from field and its organisation
7 RAM Parameters to be incorporated into LCC Model
7.1 Introduction
7.2 Overview of LCC Modelling
7.3 RAM parameters for LCC
Annex A - Examples of breakdown structure
Bibliography
Gives guidance on applying the RAM requirements in EN 50126-1 to rolling stock and for dealing with RAM activities during the system life cycle phases from invitation to tender to demonstration in operation only.
Committee |
GEL/9/2
|
DevelopmentNote |
Supersedes 04/30116340 DC (06/2006)
|
DocumentType |
Standard
|
Pages |
66
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
This document provides guidance on applying the RAM requirements in EN 50126-1 to rolling stock and for dealing with RAM activities during the system life cycle phases from invitation to tender to demonstration in operation only. All references to EN 50126-1 concern the version of 1998.
The guide is aimed at the customers/operators and main suppliers of rolling stock. The main purpose of the guide is to:
enable a customer/operator of rolling stock:
to specify the RAM requirements addressing the type of operation in terms of the end customer needs, considering service availability and economic considerations;
to evaluate different tenders, in terms of RAM requirements, on a common basis with the aid of specific RAM documents;
to gain assurance, during design/development phase, that the rolling stock being offered is likely to satisfy the RAM contractual requirements by examining step by step detailed and specific RAM documents as an output of the RAM activities performed during the development phase;
to validate that the rolling stock, as delivered, satisfies the specified RAM requirements
to enable the main supplier of rolling stock
to understand the customers/operators RAM requirements
to provide substantive information/visibility in a tender to show that the product offered is likely to satisfy the RAM requirements by performing preliminary RAM analysis;
to provide substantive information during design/development phase to show that the product offered is likely to satisfy the RAM requirements by performing detailed RAM analysis;
to demonstrate that the product delivered satisfies the RAM requirements; Regarding LCC, this application guide is restricted to providing only the key RAM parameters necessary to be incorporated into an LCC Model. This application guide excludes:
RAM values connected to the different RAM requirements (however, it contains a simple guide line of actions for supporting the decision making process and choosing appropriate values, see 5.4)
specific RAM documents to be produced and activities to be performed. However, it provides, only as an example, typical data and document templates for recording the output of a RAM analysis).
Standards | Relationship |
CLC/TR 50126-3:2008 | Identical |
PD ISO/TR 37152:2016 | Smart community infrastructures. Common framework for development and operation |
IEC 60300-3-3:2017 | Dependability management - Part 3-3: Application guide - Life cycle costing |
EN 15380-2:2006 | Railway applications - Designation system for railway vehicles - Part 2: Product groups |
EN 50126-1:2017 | Railway Applications - The Specification and Demonstration of Reliability, Availability, Maintainability and Safety (RAMS) - Part 1: Generic RAMS Process |
EN 60721-1:1995/A2:1995 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 1: ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES |
CLC/TR 50126-2:2007 | Railway applications - The specification and demonstration of Reliability, Availability, Maintainability and Safety (RAMS) - Part 2: Guide to the application of EN 50126-1 for safety |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.