PD CEN/TS 16817-1:2015
Current
The latest, up-to-date edition.
Ambient air. Monitoring the effects of genetically modified organisms (GMO). Pollen monitoring Technical pollen sampling using pollen mass filter (PMF) and Sigma-2-sampler
Hardcopy , PDF
English
31-10-2015
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Basic principle of the procedure
5 Sampling
6 Sampling procedure
7 Microscopic pollen analysis
8 Molecular-biological analyses of GMO
9 Determination of the target parameters for
GMO monitoring and representation of the
results
10 Performance characteristics of the methods
11 Quality assurance and quality control
Annex A (normative) - Maize-specific requirements
Bibliography
Explains a procedure for the use of the passive samplers Sigma-2 and PMF to sample airborne pollen.
Committee |
EH/2/3
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This Technical Specification describes a procedure for the use of the passive samplers Sigma-2 and PMF to sample airborne pollen. Both are designed to sample coarse aerosol particles. Collected samples are used to analyse pollen input with regard to pollen type and amount, and input of transgenic pollen. The Sigma-2 passive sampler here provides a standardized sampling method for direct microscopic pollen analysis and quantifying the input of airborne pollen at the site. The PMF yields sufficient amounts of pollen to additionally carry out molecular-biological diagnostics for detection of GMO.
Essential background information on performing GMO monitoring is given in VDI/Guideline 4330 Part 1 [4], which is based on an integrated assessment of temporal and spatial variation of GMO cultivation (sources of GMO), the exposure in the environment and biological/ecological effects. Ideally, the pollen sampling using technical samplers for GMO monitoring should be undertaken in combination with the biological collection of pollen by bees (CEN/TS 16817-2).
The application of technical passive samplers and the use of honey bee colonies as active biological collectors complement each other in a manifold way when monitoring the exposure to GMO pollen. Technical samplers provide results regarding the pollen input at the sampling site in a representative way, whereas with biological sampling by honey bee colonies, pollen from flowering plants in the area is collected according to the bees\' collection activity. Thus, this method represents GMO exposure to roaming insects. By combining the two sampling methods these two main principles of exposure are represented. Furthermore, a broad range of pollen species is covered.
The sample design depends on the intended sampling objective. Some examples are given in 6.2.
Standards | Relationship |
CEN/TS 16817-1:2015 | Identical |
ISO 5725-1:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions |
CEN/TS 16817-2:2015 | Ambient air - Monitoring the effects of genetically modified organisms (GMO) - Pollen monitoring - Part 2: Biological pollen sampling using bee colonies |
VDI 4330 Blatt 3:2007-01 | Monitoring the effects of genetically modified organisms (GMO) - Pollen monitoring - Technical pollen sampling using pollen mass filter (PMF) and Sigma-2 sampler |
VDI 4330 Blatt 1:2006-10 | Monitoring the ecological effects of genetically modified organisms - Genetically modified plants - Basic principles and strategies |
DIN 32645:2008-11 | CHEMICAL ANALYSIS - DECISION LIMIT, DETECTION LIMIT AND DETERMINATION LIMIT UNDER REPEATABILITY CONDITIONS - TERMS, METHODS, EVALUATION |
VDI 4330 Blatt 4:2006-10 | Monitoring the effects of genetically modified organisms (GMO) - Pollen monitoring - Biological pollen sampling using bee colonies |
DIN 10760:2002-05 | ANALYSIS OF HONEY - DETERMINATION OF THE RELATIVE FREQUENCY OF POLLEN |
VDI 2119:2013-06 | Ambient air measurements - Sampling of atmospheric particles > 2,5 ?m on an acceptor surface using the Sigma-2 passive sampler - Characterisation by optical microscopy and calculation of number settling rate and mass concentration |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.