PD 6531:1997

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Queries and interpretations on BS 5839:Parts 1 and 4 (as amended)

Available format(s)

Hardcopy , PDF

Superseded date

30-10-2010

Language(s)

English

Published date

15-07-1997

$443.41
Including GST where applicable

Foreword
1 Scope
2 Interpretation of BS 5839: Part 1:1988
  2.1 Manual and automatic systems
  2.2 Short circuit monitoring
  2.3 Monitoring of alarm sounder circuits
  2.4 The use of isolators between zones
  2.5 Addressable detector/sounder circuits
  2.9 Disk memories
  2.10 "Search distance" in addressable systems
  2.11 Zoning of multi-storey buildings
  2.12 Starting or restarting fire alarm sounders
  2.13 Loudness of alarms in residential care homes
  2.14 Loudness measurement for voice alarm signals
  2.15 Travel distance to manual call points
  2.16 Positioning of detectors in a roof apex
  2.17 Detectors in ventilated ceiling voids
  2.18 Optical beam detectors in congested roof spaces
  2.19 Siting of detectors near ceiling obstructions
  2.20 Detectors in lift shafts
  2.21 Detectors in ventilation ducts
  2.22 Use of L2 and L3 systems
  2.23 Smoke detector standards for type L Systems
  2.24 Smoke detectors used to operate door-holding
       devices
  2.25 Door smoke seals
  2.26 Sprinkler protection
  2.27 Time delays
  2.28 Reduced sensitivity
  2.29 Remote isolation facilities
  2.30 Diagrammatic representation of the building
  2.31 Connection to mains supplies
  2.32 Fire protection of mains wiring to fire alarm
       systems
  2.33 Use of standby generators
  2.34 Conditions to be satisfied for absence of
       mechanical protection to cables
  2.35 Rodent attack on cables
  2.36 'Low smoke' cables
  2.37 Fire resistant armoured cables
  2.38 Cabling of ring-connected data-transmission
       systems
  2.39 Radio-linked sounders
  2.40 Ancillary services
  2.41 Testing of manual call points
  2.42 Zone testing
  2.43 Testing voltages
  2.44 Insulation testing at the 5-year test
  2.45 Cable fixings
3 Interpretations of BS 5839:Pt4:1988
  3.1 Silencing of facilities
  3.2 Short circuit warnings
  3.3 Fire alarm response to manual call point
  3.4 Earth faults
  3.5 Fault location displays
  3.6 Memory check sums
  3.7 Disk memories: see 2.9 of this Published Document
  3.8 Memory check routines
  3.9 Total loss of power
  3.10 Battery monitoring current
Subject index
List of references

Deals with interpretations on both standards in the form of questions and answers.

Committee
FSH/12/1
DevelopmentNote
Supersedes BS PD6531(1992). (08/2005)
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Superseded
Supersedes

BS 5588-2:1985 Fire precautions in the design, construction and use of buildings Code of practice for shops
BS 5655-1:1979 Lifts and service lifts Safety rules for the construction and installation of electric lifts
BS EN 60651:1994 Specification for sound level meters
BS 6387:1983 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions
BS 6004:1984 Specification for PVC-insulated cables (non-armoured) for electric power and lighting
BS 6724:1986 Specification for armoured cables for electricity supply having thermosetting insulation with low emission of smoke and corrosive gases when affected by fire
BS 5588-6:1991 Fire precautions in the design, construction and use of buildings Code of practice for places of assembly
BS 5467:1977 Specification for armoured cables with thermosetting insulation for electricity supply
BS 5588-3:1983 Fire precautions in the design, construction and use of buildings Code of practice for office buildings
BS 5839-4:1988 Fire detection and alarm systems for buildings Specification for control and indicating equipment
BS 6346:1987 Specification for PVC-insulated cables for electricity supply
BS 7443:1991 Specification for sound systems for emergency purposes
BS 5446-1:1977 Specification for components of automatic fire alarm systems for residential premises. Point-type smoke detectors
BS 5445-7:1984 Components of automatic fire detection systems Specification for point-type smoke detectors using scattered light, transmitted light or ionization

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more