ONORM EN 13476-1 : 2008

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 1: GENERAL REQUIREMENTS AND PERFORMANCE CHARACTERISTICS

Withdrawn date

28-02-2019

Superseded by

ÖNORM EN 13476-1:2019

Published date

12-01-2013

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions, symbols and abbreviations
   3.1 Definitions
        3.1.1 General definitions
        3.1.2 Geometrical definitions
   3.2 Symbols and abbreviations
4 Material
   4.1 General
   4.2 Utilisation of non-virgin material
   4.3 Sealing ring retaining components
   4.4 Sealing rings
   4.5 Fused or welded joints
5 Designation of wall construction
6 Appearance and colour
   6.1 Appearance
   6.2 Colour
7 Geometrical characteristics
8 Types of fittings
   8.1 General
   8.2 Design length of fittings
9 System performance related test methods and characteristics
10 Marking, general
   10.1 Presentation
   10.2 Marking process
   10.3 Size
Annex A (informative) Characteristics of PVC-U, PP and PE pipes
        and fittings
        A.1 General
        A.2 Material characteristics
        A.3 Chemical resistance
        A.4 Abrasion resistance
        A.5 Hydraulic roughness
Annex B (informative) Structural design
        B.1 General
        B.2 Structural design based on practical experience
        B.3 Structural design based on a design calculations
        B.4 Selection of fitting stiffness or class
Annex C (informative) Designation of pipes and corresponding
        fittings
Annex D (informative) Guidance in cleaning plastics pipes
        D.1 Introduction
        D.2 Cleaning and unblocking
            D.2.1 Choosing the right equipment
            D.2.2 Comparing techniques
        D.3 Conclusions from independent jetting tests
            D.3.1 Assessing efficiency and impact
            D.3.2 Testing of plastic pipes
            D.3.3 Clearing tests
        D.4 Supplementary cleaning techniques
        D.5 Recommended practice principles for jetting
National Annex NA (informative) to BS EN 13476-1:2007
Additional guidance for UK users
Bibliography

Describes the definitions and general requirements for pipes, fittings and the system based on unplasticized poly(vinyl chloride) (PVC-U), polypropylene (PP) and polyethylene (PE) structured-wall piping systems that are to be used for non-pressure underground drainage and sewerage systems.

DocumentType
Standard
PublisherName
Osterreichisches Normungsinstitut/Austrian Standards
Status
Withdrawn
SupersededBy

ONORM EN 13476-3 : 2015 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 3: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND PROFILED EXTERNAL SURFACE AND THE SYSTEM, TYPE B (AMENDMENT)
ONORM EN 13598-1 : 2011 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 1: SPECIFICATIONS FOR ANCILLARY FITTINGS INCLUDING SHALLOW INSPECTION CHAMBERS
ONORM EN 13476-2 : 2015 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 2: SPECIFICATIONS FOR PIPES AND FITTINGS WITH SMOOTH INTERNAL AND EXTERNAL SURFACE AND THE SYSTEM, TYPE A (AMENDMENT)
ONORM ONR CEN/TS 13476-4 : JUL 2013 PLASTICS PIPING SYSTEMS FOR NON-PRESSURE UNDERGROUND DRAINAGE AND SEWERAGE - STRUCTURED-WALL PIPING SYSTEMS OF UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U), POLYPROPYLENE (PP) AND POLYETHYLENE (PE) - PART 4: GUIDANCE FOR THE ASSESSMENT OF CONFORMITY (CEN/TS 13476-4:2013)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more