NFPA 664 : 2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
PREVENTION OF FIRES AND EXPLOSIONS IN WOOD PROCESSING AND WOODWORKING FACILITIES
Hardcopy
10-11-2020
English
01-01-2017
Chapter 1 - Administration
Chapter 2 - Referenced Publications
Chapter 3 - Definitions
Chapter 4 - General Requirements
Chapter 5 - Performance-Based Design Option
Chapter 6 - Building Construction
Chapter 7 - Prevention of Ignition and Control of
Ignition Sources
Chapter 8 - Processes, Operations, and Special
Systems
Chapter 9 - Fire Protection
Chapter 10 - Human Element
Chapter 11 - Housekeeping
Annex A - Explanatory Material
Annex B - Explosion Protection
Annex C - Informational Primer on Spark Detection
and Extinguishing Systems
Annex D - Conveying System Isolation
Annex E - Automatic Water Spray Deluge Protection
for Dryer Systems
Annex F - Informational References
Index
Gives the minimum requirements for fire and explosion prevention and protection of industrial, commercial, or institutional facilities that process wood or manufacture wood products, using wood or other cellulosic fiber as a substitute for or additive to wood fiber, and that process wood, creating wood chips, particles, or dust.
DevelopmentNote |
2012 Version is also available in Spanish (See NFPA 664 SPANISH). (08/2012)
|
DocumentType |
Standard
|
Pages |
86
|
PublisherName |
National Fire Protection Association
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
NFPA 499 : 2017 | CLASSIFICATION OF COMBUSTIBLE DUSTS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
NFPA 780 : 2017 | INSTALLATION OF LIGHTNING PROTECTION SYSTEMS |
NFPA 122 : 2015 | FIRE PREVENTION AND CONTROL IN METAL/NONMETAL MINING AND METAL MINERAL PROCESSING FACILITIES |
NFPA 5000 : 2018 | BUILDING CONSTRUCTION AND SAFETY CODE |
NFPA 850 : 2015 | FIRE PROTECTION FOR ELECTRIC GENERATING PLANTS AND HIGH VOLTAGE DIRECT CURRENT CONVERTER STATIONS |
NFPA 650 : 1998 | PNEUMATIC CONVEYING SYSTEMS FOR HANDLING COMBUSTIBLE PARTICULATE SOLIDS |
NFPA 704 : 2017 | STANDARD SYSTEM FOR THE IDENTIFICATION OF THE HAZARDS OF MATERIALS FOR EMERGENCY RESPONSE |
ANSI O2.1 : 1983 | SAWMILLS - SAFETY REQUIREMENTS FOR |
NFPA FIRE PROT GUIDE ON HAZARDOUS MAT : 2010 | FIRE PROTECTION GUIDE TO HAZARDOUS MATERIALS |
C22.1-15 PACKAGE | Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference |
NFPA 120 : 2015 | FIRE PREVENTION AND CONTROL IN COAL MINES |
NFPA 91 : 2015 | EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS |
ICC 2012 INTERNATIONAL BUILDING CODE : 2012 | INTERNATIONAL BUILDING CODE |
NFPA 230 : 2003 | FIRE PROTECTION OF STORAGE |
NFPA 1 : 2021 | FIRE CODE |
C22.1HB-18 | Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I |
UFC 3-410-04N : 2004 | UNIFIED FACILITIES CRITERIA - INDUSTRIAL VENTILATION |
AIHA Z9.7 : 2007 | RECIRCULATION OF AIR FROM INDUSTRIAL PROCESS EXHAUST SYSTEMS |
NFPA 1620 : 2015 | PRE-INCIDENT PLANNING |
NFPA 654 : 2017 | PREVENTION OF FIRE AND DUST EXPLOSIONS FROM THE MANUFACTURING, PROCESSING, AND HANDLING OF COMBUSTIBLE PARTICULATE SOLIDS |
ICC IBC CODE AND COMMENTARY VOLUME 2 : 2015 | IBC® Code and Commentary, Volume 2 |
ICC 2012 INTERNATIONAL FIRE CODE : 2012 | INTERNATIONAL FIRE CODE |
ICC IFC CODE & COMMENTARY VOLUME 1 & 2 : 2015 | IFC® Code and Commentary |
NFPA 484 : 2015 | COMBUSTIBLE METALS |
MIL-HDBK-1024-1 Base Document:1994 | AVIATION OPERATIONAL AND SUPPORT FACILITIES |
NFPA 497B : 1991 | RECOMMENDED PRACTICE FOR THE CLASSIFICATION OF CLASS II HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
NFPA 1 : 2018 | FIRE CODE |
NFPA 654 : 2020 | Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids |
NFPA 850:2020 | Recommended Practice for Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter Stations |
NFPA 91 : 2015 | EXHAUST SYSTEMS FOR AIR CONVEYING OF VAPORS, GASES, MISTS, AND PARTICULATE SOLIDS |
NFPA 652 : 2016 | FUNDAMENTALS OF COMBUSTIBLE DUST |
NFPA 22 : 2013 | WATER TANKS FOR PRIVATE FIRE PROTECTION |
NFPA 2001 : 2015 | CLEAN AGENT FIRE EXTINGUISHING SYSTEMS |
NFPA 750 : 2015 | WATER MIST FIRE PROTECTION SYSTEMS |
NFPA 25 : 2017 | INSPECTION, TESTING, AND MAINTENANCE OF WATER-BASED FIRE PROTECTION SYSTEMS |
NFPA 31 : 2016 | INSTALLATION OF OIL-BURNING EQUIPMENT |
ASME B31.1 : 2016 | POWER PIPING |
NFPA 34 : 2015 | DIPPING, COATING, AND PRINTING PROCESSES USING FLAMMABLE OR COMBUSTIBLE LIQUIDS |
NFPA 780 : 2017 | INSTALLATION OF LIGHTNING PROTECTION SYSTEMS |
VDI 3673:1979-06 | Pressure release of dust explosions |
NFPA 654 : 2017 | PREVENTION OF FIRE AND DUST EXPLOSIONS FROM THE MANUFACTURING, PROCESSING, AND HANDLING OF COMBUSTIBLE PARTICULATE SOLIDS |
NFPA 505 : 2013 | FIRE SAFETY STANDARD FOR POWERED INDUSTRIAL TRUCKS INCLUDING TYPE DESIGNATIONS, AREAS OF USE, CONVERSIONS, MAINTENANCE, AND OPERATIONS |
NFPA 101 : 2018 | LIFE SAFETY CODE |
NFPA 221 : 2018 | HIGH CHALLENGE FIRE WALLS, FIRE WALLS, AND FIRE BARRIER WALLS |
NFPA 80A : 2017 | PROTECTION OF BUILDINGS FROM EXTERIOR FIRE EXPOSURES |
ASME B31.3:2016 | PROCESS PIPING |
NFPA 17 : 2017 | DRY CHEMICAL EXTINGUISHING SYSTEMS |
NFPA 69 : 2014 | EXPLOSION PREVENTION SYSTEMS |
NFPA 2113 : 2012 | SELECTION, CARE, USE, AND MAINTENANCE OF FLAME-RESISTANT GARMENTS FOR PROTECTION OF INDUSTRIAL PERSONNEL AGAINST SHORT-DURATION THERMAL EXPOSURES FROM FIRE |
NFPA 33 : 2016 | SPRAY APPLICATION USING FLAMMABLE OR COMBUSTIBLE MATERIALS |
NFPA 1600 : 2016 | DISASTER/EMERGENCY MANAGEMENT AND BUSINESS CONTINUITY/CONTINUITY OF OPERATIONS PROGRAMS |
ASTM E 1515 : 2014 : REDLINE | Standard Test Method for Minimum Explosible Concentration of Combustible Dusts |
NFPA 24 : 2016 | INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES |
NFPA 15 : 2017 | WATER SPRAY FIXED SYSTEMS FOR FIRE PROTECTION |
NFPA SFPE PERFORMANCE BASED FIRE PROT : 2006 | SFPE ENGINEERING GUIDE TO PERFORMANCE-BASED FIRE PROTECTION |
NFPA 10 : 2018 | PORTABLE FIRE EXTINGUISHERS |
ISO 6184-1:1985 | Explosion protection systems Part 1: Determination of explosion indices of combustible dusts in air |
NFPA 68 : 2013 | EXPLOSION PROTECTION BY DEFLAGRATION VENTING |
NFPA 14 : 2016 | INSTALLATION OF STANDPIPE AND HOSE SYSTEMS |
NFPA 55 : 2016 | COMPRESSED GASES AND CRYOGENIC FLUIDS CODE |
ASTM E 1591 : 2013 | Standard Guide for Obtaining Data for Fire Growth Models |
NFPA 51B : 2014 | FIRE PREVENTION DURING WELDING, CUTTING, AND OTHER HOT WORK |
NFPA 70E : 2018 | ELECTRICAL SAFETY IN THE WORKPLACE |
NFPA 11 : 2016 | LOW-, MEDIUM-, AND HIGH-EXPANSION FOAM |
NFPA 85 : 2015 | BOILER AND COMBUSTION SYSTEMS HAZARDS CODE |
NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
NFPA 12 : 2015 | CARBON DIOXIDE EXTINGUISHING SYSTEMS |
ISO 6184-4:1985 | Explosion protection systems Part 4: Determination of efficacy of explosion suppression systems |
NFPA 600 : 2015 | INDUSTRIAL FIRE BRIGADES |
NFPA 1 : 2018 | FIRE CODE |
NFPA 499 : 2017 | CLASSIFICATION OF COMBUSTIBLE DUSTS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
NFPA FIRE PROT GUIDE ON HAZARDOUS MAT : 2010 | FIRE PROTECTION GUIDE TO HAZARDOUS MATERIALS |
NFPA 72 : 2016 | NATIONAL FIRE ALARM AND SIGNALING CODE |
NFPA 13 : 2016 | INSTALLATION OF SPRINKLER SYSTEMS |
CFR 30(PTS1-199) : JUL 2017 | MINERAL RESOURCES - MINE SAFETY & HEALTH ADMINISTRATION, DEPARTMENT OF LABOUR |
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
NFPA 77 : 2014 | STATIC ELECTRICITY |
NFPA 2112 : 2018 | FLAME-RESISTANT GARMENTS FOR PROTECTION OF INDUSTRIAL PERSONNEL AGAINST FLASH FIRE |
NFPA 54 : 2018 | NATIONAL FUEL GAS CODE |
NFPA 82 : 2014 | INCINERATORS AND WASTE AND LINEN HANDLING SYSTEMS AND EQUIPMENT |
ASME PV CODE SET : 2017 | BOILER AND PRESSURE VESSEL CODE - COMPLETE SET |
NFPA 20 : 2016 | INSTALLATION OF STATIONARY PUMPS FOR FIRE PROTECTION |
NFPA 80 : 2016 | FIRE DOORS AND OTHER OPENING PROTECTIVES |
NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.