NFPA 270:2023

Current

Current

The latest, up-to-date edition.

Standard Test Method for Measurement of Smoke Obscuration Using a Conical Radiant Source in a Single Closed Chamber

Available format(s)

Hardcopy

Language(s)

English

Published date

19-12-2022

$365.85
Including GST where applicable

Chapter 1 Administration
1.1 Scope.
1.2 Purpose. (Reserved)
1.3 Application.
1.4 Units and Formulas.
Chapter 2 Referenced Publications
2.1 General.
2.2 NFPA Publications. (Reserved)
2.3 Other Publications.
2.4 References for Extracts in Mandatory Sections. (Reserved)
Chapter 3 Definitions
3.1 General.
3.2 NFPA Official Definitions.
3.3 General Definitions.
Chapter 4 Test Apparatus
4.1 General.
4.2 Test Chamber.
4.3 Sample Support and Heating Arrangements.
4.4 Gas Supply.
4.5 Photometric System.
4.6 Chamber Leakage.
4.7 Cleaning Materials.
4.8 Ancillary Equipment.
Chapter 5 Test Environment
5.1 Light Interference.
5.2 Product of Combustion Venting.
5.3 Operator Safety.
Chapter 6 Test Specimen
6.1 Suitability of Sample for Testing.
6.2 Sample Face.
6.3 Number of Specimens.
6.4 Additional Specimens.
6.5 Size of Specimens.
6.6 Specimen Preparation.
6.7 Wrapping of Specimens.
Chapter 7 Setup, Calibration, and Maintenance
7.1 Setup and Calibration Procedures.
7.2 Alignment of Photometric System.
7.3 Selection of Compensating Filter(s).
7.4 Linearity Check.
7.5 Calibration of Range-Extension Filter.
7.6 Chamber Leakage Rate Test.
7.7 Burner Calibration.
7.8 Radiator Cone Calibration.
7.9 Cleaning.
7.10 Frequency of Checking and Calibrating Procedures.
7.11 Total System.
Chapter 8 Conditioning
8.1 Pre-Test.
8.2 Conditioning.
Chapter 9 Test Procedure
9.1 Initial Conditions.
9.2 Tests with Pilot Flame.
9.3 Preparation of Photometric System.
9.4 Loading Specimen.
9.5 Recording of Light Transmission.
9.6 Observations.
9.7 Termination of Test.
9.8 Specimen Mass.
9.9 Repeat Tests.
Chapter 10 Calculations
10.1 Specific Optical Density, Ds.
10.2 Clear Beam Correction Factor, Dc.
10.3 Mass Loss.
Chapter 11 Test Report
11.1 Descriptive Information.
11.2 Test Results.
Annex A Explanatory Material
Annex B Precision and Bias
Annex C Interlaboratory Application
Annex D Determination of Mass Optical Density
Annex E Informational References

This is fire-test-response standard.

DocumentType
Test Method
ISBN
978-145592981-8
Pages
38
PublisherName
National Fire Protection Association
Status
Current
Supersedes

NFPA 289:2023 Standard Method of Fire Test for Individual Fuel Packages
NFPA 556:2024 Guide on Methods for Evaluating Fire Hazard to Occupants of Passenger Road Vehicles

ASTM E 176 : 2010 Standard Terminology of Fire Standards
ASTM C 1288 : 2017 Standard Specification for Fiber-Cement Interior Substrate Sheets

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.