Avant-propos
1 Domaine d'application
2 Références normatives
3 Définitions
4 Classification
5 Caractéristiques des PCDM
6 Marquage et indications
7 Conditions normales de fonctionnement en service et
  d'installation
8 Prescriptions de construction et de fonctionnement
9 Essais
Figures
Annexe A Séquences d'essais et nombre d'échantillons à
          essayer en vue de la vérification de la
          conformité à la présente norme
Annexe B Essais individuels de série
Annexe C Détermination des distances d'isolement et des
          lignes de fuite
Annexe D Liste des essais, des séquences d'essais
          supplémentaires et nombres des exemplaires pour
          la vérification de conformité des PCDM aux
          prescriptions de compatibilité électromagnétique
          (CEM)
Annexe ZA Références normatives à d'autres publications
          internationales avec les publications européennes
          correspondantes
Annexe ZB Conditions nationales particulières

La présente Norme internationale s'applique aux dispositifs mobiles pour usages domestiques et analogues (appelés par la suite PCDM) comprenant une fiche de prise de courant, un dispositif différentiel incorporé fonctionnellement indépendant ou fonctionnellement dépendant de la tension d'alimentation, et un ou plusieurs socles de prises de courant. Elles ne comprennent pas de dispositif de protection contre les surintensités incorporé. Elles sont destinées à des circuits monophasés pour des tensions assignées ne dépassant pas 250 V alternatifs par rapport à la terre en courant alternatif pour des courants assignés ne dépassant pas 16 A. Elles sont destinées à procurer une protection contre les chocs électriques en cas de contact direct en complément à la protection procurée par l'installation fixe au circuit en aval. Les PCDM ont un courant différentiel assigné ne dépassant pas 0,03 A. Elles assurent le déclenchement en cas de courants résiduels alternatifs et de courants résiduels continus pulsés appliqués brusquement ou augmentant lentement (voir 8.15). Les parties prises et fiches seront conformes aux normes nationales s'y référant. La présente norme s'applique aux dispositifs mobiles remplissant à la fois les fonctions de détection du courant résiduel, de comparaison de la valeur de ce courant à une valeur de fonctionnement différentiel et d'ouverture du circuit protégé quand le courant différentiel résiduel dépasse cette valeur. Elles ne sont pas destinées à être utilisées comme parties d'installations fixes. Leurs moyens de connexion peuvent être des fiches, des socles de prises de courant, des bornes ou des câbles.

DevelopmentNote
Indice de Classement: C61-460. PR NFC 61 460 December 1999. (02/2002)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60384-14:2013+AMD1:2016 CSV Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
IEC 60695-2-1:1991 Fire hazard testing - Part 2: Test methods - Section 1: Glow-wire test and guidance
HD 214 : 200S2 RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS
EN 60065:2014/AC:2017-01 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016)
NF EN ISO 306 : 2014 PLASTICS - THERMOPLASTIC MATERIALS - DETERMINATION OF VICAT SOFTENING TEMPERATURE (VST)
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control
IEC 61543:1995 Residual current-operated protective devices (RCDs) for household and similar use - Electromagnetic compatibility
NF EN 61543 : 96 AMD 2 2006 RESIDUAL CURRENT-OPERATED PROTECTIVE DEVICES (RCDS) FOR HOUSEHOLD AND SIMILAR USE - ELECTROMAGNETIC COMPATIBILITY
NF EN 60529 : 92 AMD 2 2014 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE)
1973/23/EEC : 1973 COUNCIL DIRECTIVE OF 19 FEBRUARY 1973 ON THE HARMONIZATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
ISO/IEC Guide 2:2004 Standardization and related activities — General vocabulary
IEC 60664-3:2016 Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution
IEC 60068-2-28:1990 Environmental testing - Part 2: Tests. Guidance for damp heat tests
NFC 26 220 : 1980 METHODS OF TESTING INSULATING MATERIALS - METHODS FOR DETERMINING THE COMPARATIVE AND THE PROOF TRACKING INDICES OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS
NF EN 60068 2-30 : 2006 ENVIRONMENTAL TESTING - PART 2-30: TESTS - TEST DB AND GUIDANCE: DAMP HEAT, CYCLIC (12 H + 12 H CYCLE)
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 45020 : 2006 STANDARDIZATION AND RELATED ACTIVITIES - GENERAL VOCABULARY
HD 625.3 : 200S1 INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 3: USE OF COATINGS TO ACHIEVE INSULATION COORDINATION OF PRINTED BOARD ASSEMBLIES
HD 243 : S12 GRAPHICAL SYMBOLS FOR USE ON EQUIPMENT - INDEX, SURVEY AND COMPILATION OF THE SINGLE SHEETS
NFC 15 100 : 2002 AMD 5 2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more