NFC 33 064 : 1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - INDOOR OR OUTDOOR POLYMERIC TERMINATIONS, WITHOUT PORCELAIN INSULATOR, FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 150 KV (UM EQUAL TO 170 KV)

Superseded date

01-08-2008

Superseded by

NFC 33 254 : 2016

Published date

12-01-2013

Sorry this product is not available in your region.

AVANT-PROPOS
1 Généralités
  1.1 Domaine d'application
  1.2 Références normatives
  1.3 Définitions
  1.4 Tension assignée
  1.5 Renseignements à fournir lors d'une commande
2 Capacité de transport
3 Constitution des extrémités
4 Caractéristiques des constituants
  4.1 Choix des matériaux
  4.2 Pièce de raccordement
  4.3 Dispositif de fixation
  4.4 Prises d'écran
  4.5 Dispositifs d'étanchéité
  4.6 Dispositif de collecte des courants de fuite
5 Installation sur le site
6 Essai de type
  6.1 Essai de tenue à la flexion (extrémités de type autoporteur)
  6.2 Essais de courte durée de l'isolation
  6.3 Essai de longue durée avec cycles thermiques
  6.4 Essai de vieillissement sous contraintes climatiques
  6.5 Essai de court-circuit de la prise d'écran
7 Essais après pose
  7.1 Essai diélectrique de l'isolation
  7.2 Essais d'isolement de la prise d'écran
8 Procédure d'acceptation de type
9 Extension de l'acceptation de type en fonction de la section
10 Extension de l'acceptation de type en fonction de la tension
Annexe A (normative) - Règles de dimensionnement des extrémités
                         de type extérieur
Annexe B (normative) - Tenue au cheminement des matériaux utilisés
                         pour les extrémités de type extérieur
Annexe C (normative) - Essai de vieillissement accéléré sous conditions
                         climatiques simulées
Annexe D (informative) - Conditions de fonctionnement et d'installation
                         sur le réseau électrique français
Annexe E (informative) - Calcul du courant de court-circuit en tenant
                         compte des effets de l'asymétrie supposée
                         maximale

DevelopmentNote
Indice de Classement: C33-064 (04/2003)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

IEC 60228:2004 Conductors of insulated cables
NF EN 60071-1 : 2006 AMD 1 2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
NFC 33 220 : 88 AMD 1 88 INSULATED OR PROTECTED CABLES FOR POWER SYSTEMS - EXTRUDED SOLID DIELECTRIC INSULATED CABLES FOR RATED VOLTAGES FROM 1.8/3(3.6) KV UP TO 18/30(36) KV
XP C20 540 : 2002 XP ENVIRONMENTAL TESTING - TEST METHODS - CLIMATIC AGEING TEST OF EQUIPMENT AND SYNTHETIC MATERIALS FOR OUTDOOR USE
NFC 63 061 : 1973 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONNECTION JOINTS FOR CONDUCTORS ONE AT LEAST OF THEM BEING AN INSULATED ALUMINIUM OR ALUMINIUM ALLOY CONDUCTOR - ELECTRICAL TEST REQUIREMENTS
IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
NFC 33 252 : 2002 TESTS FOR POWER CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30kV (Um=36kV) UP TO 150 kV (Um=170kV)
NFC 33 062 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SF6 INSULATED METAL ENCLOSED TERMINATIONS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
IEC 60230:1966 Impulse tests on cables and their accessories
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
NFC 32 013 : 1981 INSULATED CABLES AND FLEXIBLE CORDS - CONDUCTORS OF INSULATED CABLES
NFC 32 024 : 88 ADD 1 93 COMMON TEST METHODS FOR INSULATING & SHEATHING MATERIALS OF ELECTRIC CABLES: METHODS FOR GENERAL APPLICATION: MEASUREMENT OF THICKNESS OVERALL DIMENSIONS TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
NF EN 60811 1-1 : 96 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 1: MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
NFC 20 711 : 1987 BASIC ENVIRONMENTAL TESTING PROCEDURES. TEST METHODS. TEST Ka - SALT MIST
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
IEC 60885-2:1987 Electrical test methods for electric cables. Part 2: Partial discharge tests

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.