AVANT-PROPOS
1 Généralités
  1.1 Domaine d'application
  1.2 Objet
  1.3 Marquage commun
2 Définitions
  2.1 Définitions relatives aux matériaux de l'enveloppe
      isolante et de la gaine, et à leur mise en oeuvre
  2.2 Définitions relatives aux essais
  2.3 Tension assignée
3 Marques et indications
  3.1 Marque d'origine
  3.2 Continuité du marquage
  3.3 Durabilité
  3.4 Lisibilité
  3.5 Marquage commun
  3.6 Usage du nom CENELEC
  3.7 Code de désignation
4 Repérage des conducteurs
  4.1 Prescriptions générales
  4.2 Code de couleurs
  4.3 Combinaisons des couleurs verte et jaune
  4.4 Identification du conducteur des câbles souples par
      la méthode du 'Marquage par inscription'
5 Prescriptions générales sur la constitution des conducteurs
  et câbles
  5.1 Ames
  5.2 Enveloppe isolante
  5.3 Bourrage
  5.4 Tresse textile
  5.5 Gaine
  5.6 Essais sur les conducteurs et câbles complets
6 Guide d'emploi des conducteurs et câbles
Annexe A (normative) - Références normatives
Annexe B (informative) - Marquage national
Annexe C (informative) - Correspondance entre les documents
                         internationaux cités en référence et
                         les documents CENELEC et/ou français
                         à appliquer

Le HD 22 s'applique aux conducteurs et câbles souples et rigides, gainés ou non gainés, ayant une enveloppe isolante réticulée, de tension assignée UOIU au plus égale à 450/750 V, utilisés dans les installations d'énergie. NOTE: Le terme 'cordon' est utilisé pour désigner certains types de câbles souples. La présente partie mentionne les prescriptions générales applicables à ces câbles. Les méthodes d'essais spécifiées sont données dans la Partie 2 du présent HD, ou dans les méthodes d'essais communes pour les câbles données les EN 50265, EN 50266, EN 50267, EN 50268 et dans la EN 60811. Les types particuliers de câbles sont spécifiés à partir de la Partie 3 du présent HD, et sont désignés ci-après comme les 'spécifications particulières'. Les désignations de ces types de câbles sont conformes au HD 361.

DevelopmentNote
Indice de Classement: C32-102-1. PR NFC 32 102-1 April 2002 (03/2002)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
HD 22-1 : 200S4 Identical

NFC 32 332 : 2002 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CABLES FOR SUPPLY LEADS WITH METALLIC COVERING FOR HEATING EQUIPMENT BY MEANS OF HEATING CABLES, WITH METALLIC COVERING, FOR EMBEDDING IN WALLS OF BUILDING
NFC 32 334 : 2002 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CABLES FOR SUPPLY LEADS WITH LOW ELECTROMAGNETIC RADIATIONS FOR HEATING EQUIPMENT BY MEANS OF HEATING CABLES, WITH METALLIC COVERING, FOR EMBEDDING IN WALLS OF BUILDING
NFC 32 330 : 2002 INSULATED CABLES AND CORDS FOR INSTALLATIONS AND EQUIPMENT - HEATING EQUIPMENT BY MEANS OF HEATING CABLES FOR EMBEDDING INTO WALLS OF BUILDINGS
NF EN 1218-2 : 2004 + A1 2010 SAFETY OF WOODWORKING MACHINES - TENONING MACHINES - PART 2: DOUBLE END TENONING AND/OR PROFILING MACHINES FED BY CHAIN OR CHAINS

IEC 60228:2004 Conductors of insulated cables
NFC 32 081 : 2002 IDENTIFICATION OF CORES IN CABLES AND FLEXIBLE CORDS
NF EN 50334 : 2001 MARKING BY INSCRIPTION FOR THE IDENTIFICATION OF CORES OF ELECTRIC CABLES
HD 308 S2:2001 Identification of cores in cables and flexible cords
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
NFC 32 013 : 1981 INSULATED CABLES AND FLEXIBLE CORDS - CONDUCTORS OF INSULATED CABLES
IEC 60228A:1982 First supplement - Conductors of insulated cables - Guide to the dimensional limits of circular conductors
NFC 32 080 : 1998 AMD 2 2009 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
HD 516 S2:1997/A2:2008 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
HD 402 : 200S2 STANDARD COLOURS FOR INSULATION FOR LOW-FREQUENCY CABLES AND WIRES
HD 361 : S3 AMD 1 2006 SYSTEM FOR CABLE DESIGNATION
NFC 32 102 : 1984 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - EXTRUDED SOLID DIELECTRIC INSULATED CABLES OF RATED VOLTAGE UP TO AND INCLUDING 450/750 V
UTEC 32 014 : 83 AMD 1 92 GUIDE FOR CHECKING CONDUCTORS CHARACTERISTICS
NFC 30 202 : 2000 AMD 1 2006 SYSTEM FOR CABLE DESIGNATION

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more